Cargando…
Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
BACKGROUND: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry® and CLOtes...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4534069/ https://www.ncbi.nlm.nih.gov/pubmed/26264957 http://dx.doi.org/10.1186/s12876-015-0332-0 |
Sumario: | BACKGROUND: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry® and CLOtest® kits, comparing this to the use of new Pronto Dry® test kits and histopathological evaluation of gastric mucosal biopsies. METHODS: Using a cross-sectional study design, subjects who presented for upper endoscopy due to various non-emergent causes had gastric biopsies obtained at three adjacent sites. Biopsy samples were tested for H. pylori using a reused Pronto Dry® test, a reused CLOtest®, a new Pronto Dry® test and histopathological examination. Concordance rates, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy were then determined. RESULTS: A total of 410 subjects were recruited. The sensitivity and diagnostic accuracy of reused Pronto Dry® tests were 72.60 % (95 % CI, 61.44 – 81.51) and 94.15 % (95 % CI, 91.44 – 96.04) respectively. For reused CLOtests®, the sensitivity and diagnostic accuracy were 93.15 % (95 % CI 85.95 – 97.04) and 98.29 % (95 % CI 96.52 – 99.17) respectively. There were more true positives for new and reused Pronto Dry® pallets as compared to new and reused CLOtests® when comparing colour change within 30 min vs. 31–60 min (P < 0.001 and P = 0.7 respectively). CONCLUSION: Negative Pronto Dry® and CLOtest® kits may be reused in a low prevalence setting where cost issues remain paramount. Reused CLOtest® kits have better accuracy than reused Pronto Dry® tests. Reused Pronto Dry® tests however have a more rapid colour change whilst maintaining diagnostic accuracy. |
---|