Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection

BACKGROUND: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry® and CLOtes...

Descripción completa

Detalles Bibliográficos
Autores principales: Jamaludin, Shahidi, Mustaffa, Nazri, Che Hamzah, Nor Aizal, Syed Abdul Aziz, Syed Hassan, Lee, Yeong Yeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4534069/
https://www.ncbi.nlm.nih.gov/pubmed/26264957
http://dx.doi.org/10.1186/s12876-015-0332-0
_version_ 1782385407922536448
author Jamaludin, Shahidi
Mustaffa, Nazri
Che Hamzah, Nor Aizal
Syed Abdul Aziz, Syed Hassan
Lee, Yeong Yeh
author_facet Jamaludin, Shahidi
Mustaffa, Nazri
Che Hamzah, Nor Aizal
Syed Abdul Aziz, Syed Hassan
Lee, Yeong Yeh
author_sort Jamaludin, Shahidi
collection PubMed
description BACKGROUND: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry® and CLOtest® kits, comparing this to the use of new Pronto Dry® test kits and histopathological evaluation of gastric mucosal biopsies. METHODS: Using a cross-sectional study design, subjects who presented for upper endoscopy due to various non-emergent causes had gastric biopsies obtained at three adjacent sites. Biopsy samples were tested for H. pylori using a reused Pronto Dry® test, a reused CLOtest®, a new Pronto Dry® test and histopathological examination. Concordance rates, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy were then determined. RESULTS: A total of 410 subjects were recruited. The sensitivity and diagnostic accuracy of reused Pronto Dry® tests were 72.60 % (95 % CI, 61.44 – 81.51) and 94.15 % (95 % CI, 91.44 – 96.04) respectively. For reused CLOtests®, the sensitivity and diagnostic accuracy were 93.15 % (95 % CI 85.95 – 97.04) and 98.29 % (95 % CI 96.52 – 99.17) respectively. There were more true positives for new and reused Pronto Dry® pallets as compared to new and reused CLOtests® when comparing colour change within 30 min vs. 31–60 min (P < 0.001 and P = 0.7 respectively). CONCLUSION: Negative Pronto Dry® and CLOtest® kits may be reused in a low prevalence setting where cost issues remain paramount. Reused CLOtest® kits have better accuracy than reused Pronto Dry® tests. Reused Pronto Dry® tests however have a more rapid colour change whilst maintaining diagnostic accuracy.
format Online
Article
Text
id pubmed-4534069
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-45340692015-08-13 Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection Jamaludin, Shahidi Mustaffa, Nazri Che Hamzah, Nor Aizal Syed Abdul Aziz, Syed Hassan Lee, Yeong Yeh BMC Gastroenterol Research Article BACKGROUND: Unchanged substrate in a negative rapid urease test may be reused to detect Helicobacter pylori (H. pylori). This could potentially reduce costs and wastage in low prevalence and resource-poor settings. We thus aimed to investigate the diagnostic accuracy of reused Pronto Dry® and CLOtest® kits, comparing this to the use of new Pronto Dry® test kits and histopathological evaluation of gastric mucosal biopsies. METHODS: Using a cross-sectional study design, subjects who presented for upper endoscopy due to various non-emergent causes had gastric biopsies obtained at three adjacent sites. Biopsy samples were tested for H. pylori using a reused Pronto Dry® test, a reused CLOtest®, a new Pronto Dry® test and histopathological examination. Concordance rates, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy were then determined. RESULTS: A total of 410 subjects were recruited. The sensitivity and diagnostic accuracy of reused Pronto Dry® tests were 72.60 % (95 % CI, 61.44 – 81.51) and 94.15 % (95 % CI, 91.44 – 96.04) respectively. For reused CLOtests®, the sensitivity and diagnostic accuracy were 93.15 % (95 % CI 85.95 – 97.04) and 98.29 % (95 % CI 96.52 – 99.17) respectively. There were more true positives for new and reused Pronto Dry® pallets as compared to new and reused CLOtests® when comparing colour change within 30 min vs. 31–60 min (P < 0.001 and P = 0.7 respectively). CONCLUSION: Negative Pronto Dry® and CLOtest® kits may be reused in a low prevalence setting where cost issues remain paramount. Reused CLOtest® kits have better accuracy than reused Pronto Dry® tests. Reused Pronto Dry® tests however have a more rapid colour change whilst maintaining diagnostic accuracy. BioMed Central 2015-08-12 /pmc/articles/PMC4534069/ /pubmed/26264957 http://dx.doi.org/10.1186/s12876-015-0332-0 Text en © Jamaludin et al. 2015 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Jamaludin, Shahidi
Mustaffa, Nazri
Che Hamzah, Nor Aizal
Syed Abdul Aziz, Syed Hassan
Lee, Yeong Yeh
Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
title Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
title_full Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
title_fullStr Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
title_full_unstemmed Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
title_short Diagnostic accuracy of reused Pronto Dry® test and CLOtest® in the detection of Helicobacter pylori infection
title_sort diagnostic accuracy of reused pronto dry® test and clotest® in the detection of helicobacter pylori infection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4534069/
https://www.ncbi.nlm.nih.gov/pubmed/26264957
http://dx.doi.org/10.1186/s12876-015-0332-0
work_keys_str_mv AT jamaludinshahidi diagnosticaccuracyofreusedprontodrytestandclotestinthedetectionofhelicobacterpyloriinfection
AT mustaffanazri diagnosticaccuracyofreusedprontodrytestandclotestinthedetectionofhelicobacterpyloriinfection
AT chehamzahnoraizal diagnosticaccuracyofreusedprontodrytestandclotestinthedetectionofhelicobacterpyloriinfection
AT syedabdulazizsyedhassan diagnosticaccuracyofreusedprontodrytestandclotestinthedetectionofhelicobacterpyloriinfection
AT leeyeongyeh diagnosticaccuracyofreusedprontodrytestandclotestinthedetectionofhelicobacterpyloriinfection