Cargando…

Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces

Concentric magnetic structures (ring and square) with domain wall (DW) pinning geometry are designed for biological manipulation. Magnetic beads collection was firstly demonstrated to analyse the local magnetic field generated by DWs and the effective regions to capture magnetic targets of size 1 μm...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Chen-Yu, Wei, Zung-Hang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4536140/
https://www.ncbi.nlm.nih.gov/pubmed/26270332
http://dx.doi.org/10.1371/journal.pone.0135299
_version_ 1782385700175347712
author Huang, Chen-Yu
Wei, Zung-Hang
author_facet Huang, Chen-Yu
Wei, Zung-Hang
author_sort Huang, Chen-Yu
collection PubMed
description Concentric magnetic structures (ring and square) with domain wall (DW) pinning geometry are designed for biological manipulation. Magnetic beads collection was firstly demonstrated to analyse the local magnetic field generated by DWs and the effective regions to capture magnetic targets of size 1 μm. Primary mouse embryonic fibroblasts (MEFs) are magnetically labeled by internalizing poly (styrene sulfonic acid) stabilized magnetic nanoparticles (PSS-MNPs) and then are selectively trapped by head-to-tail DWs (HH DWs) or tail-to-tail DWs (TT DWs) to be arranged into linear shape or cross shape. The morphologies and the nuclear geometry of the cells growing on two kinds of concentric magnetic structures are shown to be distinctive. The intracellular magnetic forces generated by the local magnetic field of DWs are found to influence the behaviour of cells.
format Online
Article
Text
id pubmed-4536140
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45361402015-08-20 Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces Huang, Chen-Yu Wei, Zung-Hang PLoS One Research Article Concentric magnetic structures (ring and square) with domain wall (DW) pinning geometry are designed for biological manipulation. Magnetic beads collection was firstly demonstrated to analyse the local magnetic field generated by DWs and the effective regions to capture magnetic targets of size 1 μm. Primary mouse embryonic fibroblasts (MEFs) are magnetically labeled by internalizing poly (styrene sulfonic acid) stabilized magnetic nanoparticles (PSS-MNPs) and then are selectively trapped by head-to-tail DWs (HH DWs) or tail-to-tail DWs (TT DWs) to be arranged into linear shape or cross shape. The morphologies and the nuclear geometry of the cells growing on two kinds of concentric magnetic structures are shown to be distinctive. The intracellular magnetic forces generated by the local magnetic field of DWs are found to influence the behaviour of cells. Public Library of Science 2015-08-13 /pmc/articles/PMC4536140/ /pubmed/26270332 http://dx.doi.org/10.1371/journal.pone.0135299 Text en © 2015 Huang, Wei http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Huang, Chen-Yu
Wei, Zung-Hang
Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces
title Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces
title_full Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces
title_fullStr Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces
title_full_unstemmed Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces
title_short Concentric Magnetic Structures for Magnetophoretic Bead Collection, Cell Trapping and Analysis of Cell Morphological Changes Caused by Local Magnetic Forces
title_sort concentric magnetic structures for magnetophoretic bead collection, cell trapping and analysis of cell morphological changes caused by local magnetic forces
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4536140/
https://www.ncbi.nlm.nih.gov/pubmed/26270332
http://dx.doi.org/10.1371/journal.pone.0135299
work_keys_str_mv AT huangchenyu concentricmagneticstructuresformagnetophoreticbeadcollectioncelltrappingandanalysisofcellmorphologicalchangescausedbylocalmagneticforces
AT weizunghang concentricmagneticstructuresformagnetophoreticbeadcollectioncelltrappingandanalysisofcellmorphologicalchangescausedbylocalmagneticforces