Cargando…
A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis
BACKGROUND: A noninvasive system for determining left ventricular (LV) filling pressure may help to improve personalized fluid removal goals in hemodialysis patients. We previously showed that the change in photoplethysmography (PPG) pulse amplitude measured by finger PPG during a Valsalva maneuver...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4536782/ https://www.ncbi.nlm.nih.gov/pubmed/26272208 http://dx.doi.org/10.1186/s12882-015-0135-0 |
_version_ | 1782385798072500224 |
---|---|
author | Galiatsatos, Panagis Parakh, Kapil Monti, Jennifer Thavarajah, Sumeska Aneke-Ogbu, Harriet Watson, Amaris Kim, Daniel Wang, Nae-Yuh Shafi, Tariq Silber, Harry A. |
author_facet | Galiatsatos, Panagis Parakh, Kapil Monti, Jennifer Thavarajah, Sumeska Aneke-Ogbu, Harriet Watson, Amaris Kim, Daniel Wang, Nae-Yuh Shafi, Tariq Silber, Harry A. |
author_sort | Galiatsatos, Panagis |
collection | PubMed |
description | BACKGROUND: A noninvasive system for determining left ventricular (LV) filling pressure may help to improve personalized fluid removal goals in hemodialysis patients. We previously showed that the change in photoplethysmography (PPG) pulse amplitude measured by finger PPG during a Valsalva maneuver correlates with invasively measured left ventricular end-diastolic pressure (LVEDP). This key PPG change, the ratio of finger PPG pulse amplitude at end-Valsalva to baseline, is known as the Pulse Amplitude Ratio, PAR. The objective of this study was to determine how PAR changes after fluid removal in hemodialysis. METHODS: We tested subjects with end-stage renal disease, before and after hemodialysis. Each subject performed a Valsalva maneuver with an effort of 20 mmHg for 10 s, guided by the device display. Finger PPG was recorded continuously before and during the maneuver. PAR was calculated automatically. RESULTS: Twenty-seven subjects (21 Males) ages 25–75 years were tested. Access sites were AV-fistulas of the arm predominantly. Weight decreased from 99.7 ± 36.9 kg to 97.0 ± 36.0 kg (p < 0.0003) with an average fluid removal of 3.07 ± 1.08 l. Correspondingly, PAR decreased from 0.74 ± 0.24 to 0.62 ± 0.23 (p = 0.003). The change in PAR was correlated with baseline PAR (r = 0.48, p = 0.01). CONCLUSION: An index of left heart filling pressure obtained noninvasively using finger photoplethysmography during the Valsalva maneuver is sensitive enough to detect reductions in filling pressure after fluid removal with hemodialysis. Further studies are warranted to determine if this method can be used to guide fluid removal during hemodialysis. |
format | Online Article Text |
id | pubmed-4536782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45367822015-08-15 A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis Galiatsatos, Panagis Parakh, Kapil Monti, Jennifer Thavarajah, Sumeska Aneke-Ogbu, Harriet Watson, Amaris Kim, Daniel Wang, Nae-Yuh Shafi, Tariq Silber, Harry A. BMC Nephrol Research Article BACKGROUND: A noninvasive system for determining left ventricular (LV) filling pressure may help to improve personalized fluid removal goals in hemodialysis patients. We previously showed that the change in photoplethysmography (PPG) pulse amplitude measured by finger PPG during a Valsalva maneuver correlates with invasively measured left ventricular end-diastolic pressure (LVEDP). This key PPG change, the ratio of finger PPG pulse amplitude at end-Valsalva to baseline, is known as the Pulse Amplitude Ratio, PAR. The objective of this study was to determine how PAR changes after fluid removal in hemodialysis. METHODS: We tested subjects with end-stage renal disease, before and after hemodialysis. Each subject performed a Valsalva maneuver with an effort of 20 mmHg for 10 s, guided by the device display. Finger PPG was recorded continuously before and during the maneuver. PAR was calculated automatically. RESULTS: Twenty-seven subjects (21 Males) ages 25–75 years were tested. Access sites were AV-fistulas of the arm predominantly. Weight decreased from 99.7 ± 36.9 kg to 97.0 ± 36.0 kg (p < 0.0003) with an average fluid removal of 3.07 ± 1.08 l. Correspondingly, PAR decreased from 0.74 ± 0.24 to 0.62 ± 0.23 (p = 0.003). The change in PAR was correlated with baseline PAR (r = 0.48, p = 0.01). CONCLUSION: An index of left heart filling pressure obtained noninvasively using finger photoplethysmography during the Valsalva maneuver is sensitive enough to detect reductions in filling pressure after fluid removal with hemodialysis. Further studies are warranted to determine if this method can be used to guide fluid removal during hemodialysis. BioMed Central 2015-08-14 /pmc/articles/PMC4536782/ /pubmed/26272208 http://dx.doi.org/10.1186/s12882-015-0135-0 Text en © Galiatsatos et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Galiatsatos, Panagis Parakh, Kapil Monti, Jennifer Thavarajah, Sumeska Aneke-Ogbu, Harriet Watson, Amaris Kim, Daniel Wang, Nae-Yuh Shafi, Tariq Silber, Harry A. A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
title | A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
title_full | A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
title_fullStr | A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
title_full_unstemmed | A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
title_short | A finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
title_sort | finger photoplethysmography waveform during the valsalva maneuver detects changes in left heart filling pressure after hemodialysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4536782/ https://www.ncbi.nlm.nih.gov/pubmed/26272208 http://dx.doi.org/10.1186/s12882-015-0135-0 |
work_keys_str_mv | AT galiatsatospanagis afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT parakhkapil afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT montijennifer afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT thavarajahsumeska afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT anekeogbuharriet afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT watsonamaris afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT kimdaniel afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT wangnaeyuh afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT shafitariq afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT silberharrya afingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT galiatsatospanagis fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT parakhkapil fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT montijennifer fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT thavarajahsumeska fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT anekeogbuharriet fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT watsonamaris fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT kimdaniel fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT wangnaeyuh fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT shafitariq fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis AT silberharrya fingerphotoplethysmographywaveformduringthevalsalvamaneuverdetectschangesinleftheartfillingpressureafterhemodialysis |