Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy
BACKGROUND: To assess differences between four different voxel-based dosimetry methods (VBDM) for tumor, liver, and lung absorbed doses following (90)Y microsphere selective internal radiation therapy (SIRT) based on (90)Y bremsstrahlung SPECT/CT, a secondary objective was to estimate the sensitivit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4538912/ https://www.ncbi.nlm.nih.gov/pubmed/26501817 http://dx.doi.org/10.1186/s40658-015-0119-y |
_version_ | 1782386052582866944 |
---|---|
author | Mikell, Justin K Mahvash, Armeen Siman, Wendy Mourtada, Firas Kappadath, S Cheenu |
author_facet | Mikell, Justin K Mahvash, Armeen Siman, Wendy Mourtada, Firas Kappadath, S Cheenu |
author_sort | Mikell, Justin K |
collection | PubMed |
description | BACKGROUND: To assess differences between four different voxel-based dosimetry methods (VBDM) for tumor, liver, and lung absorbed doses following (90)Y microsphere selective internal radiation therapy (SIRT) based on (90)Y bremsstrahlung SPECT/CT, a secondary objective was to estimate the sensitivity of liver and lung absorbed doses due to differences in organ segmentation near the liver-lung interface. METHODS: Investigated VBDM were Monte Carlo (MC), soft-tissue kernel with density correction (SKD), soft-tissue kernel (SK), and local deposition (LD). Seventeen SIRT cases were analyzed. Mean absorbed doses ([Formula: see text] ) were calculated for tumor, non-tumoral liver (NL), and right lung (RL). Simulations with various SPECT spatial resolutions (FHWMs) and multiple lung shunt fractions (LSs) estimated the accuracy of VBDM at the liver-lung interface. Sensitivity of patient RL and NL [Formula: see text] on segmentation near the interface was assessed by excluding portions near the interface. RESULTS: SKD, SK, and LD were within 5 % of MC for tumor and NL [Formula: see text] . LD and SKD overestimated RL [Formula: see text] compared to MC on average by 17 and 20 %, respectively; SK underestimated RL [Formula: see text] on average by −60 %. Simulations (20 mm FWHM, 20 % LS) showed that SKD, LD, and MC were within 10 % of the truth deep (>39 mm) in the lung; SK significantly underestimated the absorbed dose deep in the lung by approximately −70 %. All VBDM were within 10 % of truth deep (>12 mm) in the liver. Excluding 1, 2, and 3 cm of RL near the interface changed the resulting RL [Formula: see text] by −22, −38, and −48 %, respectively, for all VBDM. An average change of −7 % in the NL [Formula: see text] was realized when excluding 3 cm of NL from the interface. [Formula: see text] was realized when excluding 3 cm of NL from the interface. CONCLUSIONS: SKD, SK, and LD are equivalent to MC for tumor and NL [Formula: see text] . SK underestimates RL [Formula: see text] relative to MC whereas LD and SKD overestimate. RL [Formula: see text] is strongly influenced by the liver-lung interface. |
format | Online Article Text |
id | pubmed-4538912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-45389122015-08-20 Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy Mikell, Justin K Mahvash, Armeen Siman, Wendy Mourtada, Firas Kappadath, S Cheenu EJNMMI Phys Article BACKGROUND: To assess differences between four different voxel-based dosimetry methods (VBDM) for tumor, liver, and lung absorbed doses following (90)Y microsphere selective internal radiation therapy (SIRT) based on (90)Y bremsstrahlung SPECT/CT, a secondary objective was to estimate the sensitivity of liver and lung absorbed doses due to differences in organ segmentation near the liver-lung interface. METHODS: Investigated VBDM were Monte Carlo (MC), soft-tissue kernel with density correction (SKD), soft-tissue kernel (SK), and local deposition (LD). Seventeen SIRT cases were analyzed. Mean absorbed doses ([Formula: see text] ) were calculated for tumor, non-tumoral liver (NL), and right lung (RL). Simulations with various SPECT spatial resolutions (FHWMs) and multiple lung shunt fractions (LSs) estimated the accuracy of VBDM at the liver-lung interface. Sensitivity of patient RL and NL [Formula: see text] on segmentation near the interface was assessed by excluding portions near the interface. RESULTS: SKD, SK, and LD were within 5 % of MC for tumor and NL [Formula: see text] . LD and SKD overestimated RL [Formula: see text] compared to MC on average by 17 and 20 %, respectively; SK underestimated RL [Formula: see text] on average by −60 %. Simulations (20 mm FWHM, 20 % LS) showed that SKD, LD, and MC were within 10 % of the truth deep (>39 mm) in the lung; SK significantly underestimated the absorbed dose deep in the lung by approximately −70 %. All VBDM were within 10 % of truth deep (>12 mm) in the liver. Excluding 1, 2, and 3 cm of RL near the interface changed the resulting RL [Formula: see text] by −22, −38, and −48 %, respectively, for all VBDM. An average change of −7 % in the NL [Formula: see text] was realized when excluding 3 cm of NL from the interface. [Formula: see text] was realized when excluding 3 cm of NL from the interface. CONCLUSIONS: SKD, SK, and LD are equivalent to MC for tumor and NL [Formula: see text] . SK underestimates RL [Formula: see text] relative to MC whereas LD and SKD overestimate. RL [Formula: see text] is strongly influenced by the liver-lung interface. Springer International Publishing 2015-07-30 /pmc/articles/PMC4538912/ /pubmed/26501817 http://dx.doi.org/10.1186/s40658-015-0119-y Text en © Mikell et al. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Article Mikell, Justin K Mahvash, Armeen Siman, Wendy Mourtada, Firas Kappadath, S Cheenu Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy |
title | Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy |
title_full | Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy |
title_fullStr | Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy |
title_full_unstemmed | Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy |
title_short | Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy |
title_sort | comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)y microsphere selective internal radiation therapy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4538912/ https://www.ncbi.nlm.nih.gov/pubmed/26501817 http://dx.doi.org/10.1186/s40658-015-0119-y |
work_keys_str_mv | AT mikelljustink comparingvoxelbasedabsorbeddosimetrymethodsintumorsliverlungandattheliverlunginterfacefor90ymicrosphereselectiveinternalradiationtherapy AT mahvasharmeen comparingvoxelbasedabsorbeddosimetrymethodsintumorsliverlungandattheliverlunginterfacefor90ymicrosphereselectiveinternalradiationtherapy AT simanwendy comparingvoxelbasedabsorbeddosimetrymethodsintumorsliverlungandattheliverlunginterfacefor90ymicrosphereselectiveinternalradiationtherapy AT mourtadafiras comparingvoxelbasedabsorbeddosimetrymethodsintumorsliverlungandattheliverlunginterfacefor90ymicrosphereselectiveinternalradiationtherapy AT kappadathscheenu comparingvoxelbasedabsorbeddosimetrymethodsintumorsliverlungandattheliverlunginterfacefor90ymicrosphereselectiveinternalradiationtherapy |