Cargando…

A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity

A time difference method to conveniently measure the phase shift between output wavelength and intensity of distributed feedback laser diodes (DFB-LDs) was proposed. This approach takes advantage of asymmetric absorption positions at the same wavelength during wavelength increase and decrease tuning...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Yongning, Chang, Jun, Lian, Jie, Liu, Zhaojun, Wang, Qiang, Zhu, Cunguang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541872/
https://www.ncbi.nlm.nih.gov/pubmed/26153767
http://dx.doi.org/10.3390/s150716153
_version_ 1782386452417478656
author Liu, Yongning
Chang, Jun
Lian, Jie
Liu, Zhaojun
Wang, Qiang
Zhu, Cunguang
author_facet Liu, Yongning
Chang, Jun
Lian, Jie
Liu, Zhaojun
Wang, Qiang
Zhu, Cunguang
author_sort Liu, Yongning
collection PubMed
description A time difference method to conveniently measure the phase shift between output wavelength and intensity of distributed feedback laser diodes (DFB-LDs) was proposed. This approach takes advantage of asymmetric absorption positions at the same wavelength during wavelength increase and decrease tuning processes in the intensity-time curve by current modulation. For its practical implementation, a measurement example of phase shift was demonstrated by measuring a time difference between the first time and the second time attendances of the same gas absorption line in the intensity-time curve during one sine or triangle modulation circle. The phase shifts at modulation frequencies ranging from 50 Hz to 50 kHz were measured with a resolution of 0.001π. As the modulation frequency increased the shift value increased with a slowed growth rate.
format Online
Article
Text
id pubmed-4541872
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-45418722015-08-26 A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity Liu, Yongning Chang, Jun Lian, Jie Liu, Zhaojun Wang, Qiang Zhu, Cunguang Sensors (Basel) Article A time difference method to conveniently measure the phase shift between output wavelength and intensity of distributed feedback laser diodes (DFB-LDs) was proposed. This approach takes advantage of asymmetric absorption positions at the same wavelength during wavelength increase and decrease tuning processes in the intensity-time curve by current modulation. For its practical implementation, a measurement example of phase shift was demonstrated by measuring a time difference between the first time and the second time attendances of the same gas absorption line in the intensity-time curve during one sine or triangle modulation circle. The phase shifts at modulation frequencies ranging from 50 Hz to 50 kHz were measured with a resolution of 0.001π. As the modulation frequency increased the shift value increased with a slowed growth rate. MDPI 2015-07-06 /pmc/articles/PMC4541872/ /pubmed/26153767 http://dx.doi.org/10.3390/s150716153 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Yongning
Chang, Jun
Lian, Jie
Liu, Zhaojun
Wang, Qiang
Zhu, Cunguang
A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
title A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
title_full A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
title_fullStr A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
title_full_unstemmed A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
title_short A Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
title_sort time difference method for measurement of phase shift between distributed feedback laser diode (dfb-ld) output wavelength and intensity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541872/
https://www.ncbi.nlm.nih.gov/pubmed/26153767
http://dx.doi.org/10.3390/s150716153
work_keys_str_mv AT liuyongning atimedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT changjun atimedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT lianjie atimedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT liuzhaojun atimedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT wangqiang atimedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT zhucunguang atimedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT liuyongning timedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT changjun timedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT lianjie timedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT liuzhaojun timedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT wangqiang timedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity
AT zhucunguang timedifferencemethodformeasurementofphaseshiftbetweendistributedfeedbacklaserdiodedfbldoutputwavelengthandintensity