Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation

An optical fiber current sensor based on Fabry-Perot interferometer using a fiber Bragg grating demodulation is proposed. Magnetic fluid is used as a sensitive medium in fiber optical Fabry-Perot (F-P) cavity for the optical characteristic of magnetic-controlled refractive index. A Fiber Bragg grati...

Descripción completa

Detalles Bibliográficos
Autores principales: Xia, Ji, Wang, Qi, Liu, Xu, Luo, Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541897/
https://www.ncbi.nlm.nih.gov/pubmed/26184201
http://dx.doi.org/10.3390/s150716632
_version_ 1782386458270629888
author Xia, Ji
Wang, Qi
Liu, Xu
Luo, Hong
author_facet Xia, Ji
Wang, Qi
Liu, Xu
Luo, Hong
author_sort Xia, Ji
collection PubMed
description An optical fiber current sensor based on Fabry-Perot interferometer using a fiber Bragg grating demodulation is proposed. Magnetic fluid is used as a sensitive medium in fiber optical Fabry-Perot (F-P) cavity for the optical characteristic of magnetic-controlled refractive index. A Fiber Bragg grating (FBG) is connected after the F-P interferometer which is used to reflect the optical power at the Bragg wavelength of the interference transmission spectrum. The corresponding reflective power of the FBG will change with different external current intensity, due to the shift on the interference spectrum of the F-P interferometer. The sensing probe has the advantages of convenient measurement for its demodulation, low cost and high current measurement accuracy on account of its sensing structure. Experimental results show that an optimal sensitivity of 0.8522 nw/A and measurement resolution of 0.001 A is obtained with a FBG at 1550 nm with 99% reflectivity.
format Online
Article
Text
id pubmed-4541897
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-45418972015-08-26 Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation Xia, Ji Wang, Qi Liu, Xu Luo, Hong Sensors (Basel) Article An optical fiber current sensor based on Fabry-Perot interferometer using a fiber Bragg grating demodulation is proposed. Magnetic fluid is used as a sensitive medium in fiber optical Fabry-Perot (F-P) cavity for the optical characteristic of magnetic-controlled refractive index. A Fiber Bragg grating (FBG) is connected after the F-P interferometer which is used to reflect the optical power at the Bragg wavelength of the interference transmission spectrum. The corresponding reflective power of the FBG will change with different external current intensity, due to the shift on the interference spectrum of the F-P interferometer. The sensing probe has the advantages of convenient measurement for its demodulation, low cost and high current measurement accuracy on account of its sensing structure. Experimental results show that an optimal sensitivity of 0.8522 nw/A and measurement resolution of 0.001 A is obtained with a FBG at 1550 nm with 99% reflectivity. MDPI 2015-07-09 /pmc/articles/PMC4541897/ /pubmed/26184201 http://dx.doi.org/10.3390/s150716632 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xia, Ji
Wang, Qi
Liu, Xu
Luo, Hong
Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
title Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
title_full Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
title_fullStr Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
title_full_unstemmed Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
title_short Fiber Optic Fabry-Perot Current Sensor Integrated with Magnetic Fluid Using a Fiber Bragg Grating Demodulation
title_sort fiber optic fabry-perot current sensor integrated with magnetic fluid using a fiber bragg grating demodulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4541897/
https://www.ncbi.nlm.nih.gov/pubmed/26184201
http://dx.doi.org/10.3390/s150716632
work_keys_str_mv AT xiaji fiberopticfabryperotcurrentsensorintegratedwithmagneticfluidusingafiberbragggratingdemodulation
AT wangqi fiberopticfabryperotcurrentsensorintegratedwithmagneticfluidusingafiberbragggratingdemodulation
AT liuxu fiberopticfabryperotcurrentsensorintegratedwithmagneticfluidusingafiberbragggratingdemodulation
AT luohong fiberopticfabryperotcurrentsensorintegratedwithmagneticfluidusingafiberbragggratingdemodulation