Cargando…

Image Quality of 3(rd) Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose

OBJECTIVES: To prospectively intra-individually compare image quality of a 3(rd) generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. METHODS: 35 patients, who had a non-contrast enh...

Descripción completa

Detalles Bibliográficos
Autores principales: Wenz, Holger, Maros, Máté E., Meyer, Mathias, Förster, Alex, Haubenreisser, Holger, Kurth, Stefan, Schoenberg, Stefan O., Flohr, Thomas, Leidecker, Christianne, Groden, Christoph, Scharf, Johann, Henzler, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4542205/
https://www.ncbi.nlm.nih.gov/pubmed/26288186
http://dx.doi.org/10.1371/journal.pone.0136054
Descripción
Sumario:OBJECTIVES: To prospectively intra-individually compare image quality of a 3(rd) generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. METHODS: 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3(rd) generation DSCT. CTDI(vol) identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3(rd)-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. RESULTS: Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (p<0.05). Mean SNR was significantly higher in all spiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*(Bonferroni0.05)<0.0024). Subjective image quality improved with increasing IR levels. CONCLUSION: Combination of 3(rd)-generation DSCT spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.