Total Knee Arthroplasty Failure Induced by Metal Hypersensitivity
Patient: Female, 70 Final Diagnosis: Metal hypersensitivity Symptoms: Joint pain • swelling • instability Medication: — Clinical Procedure: Revision total knee arthroplasty Specialty: Orthopedics and Traumatology OBJECTIVE: Unusual clinical course BACKGROUND: Metal hypersensitivity is an uncommon co...
Autores principales: | Gupta, Ryan, Phan, Duy, Schwarzkopf, Ran |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4544332/ https://www.ncbi.nlm.nih.gov/pubmed/26278890 http://dx.doi.org/10.12659/AJCR.893609 |
Ejemplares similares
-
Metallosis Presenting as Knee Pain 26 years after Primary Total Knee Arthroplasty
por: Sharareh, Behnam, et al.
Publicado: (2015) -
Availability of Total Knee Arthroplasty Implants for Metal Hypersensitivity Patients
por: Ajwani, Sanil Harji, et al.
Publicado: (2016) -
Diagnosis of Metal Hypersensitivity in Total Knee Arthroplasty: A Case Report
por: Schoon, Janosch, et al.
Publicado: (2019) -
Cutaneous Metal Hypersensitivity Syndrome in Total Knee Arthroplasty with Titanium-Coated Implant
por: Prasanna, Swati, et al.
Publicado: (2022) -
Impact of time to revision total knee arthroplasty on outcomes following aseptic failure
por: Roof, Mackenzie A., et al.