Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI
BACKGROUND: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acq...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4545455/ https://www.ncbi.nlm.nih.gov/pubmed/26501460 http://dx.doi.org/10.1186/s40658-014-0102-z |
_version_ | 1782386752699236352 |
---|---|
author | Gunzinger, Jeanne M Delso, Gaspar Boss, Andreas Porto, Miguel Davison, Helen von Schulthess, Gustav K Huellner, Martin Stolzmann, Paul Veit-Haibach, Patrick Burger, Irene A |
author_facet | Gunzinger, Jeanne M Delso, Gaspar Boss, Andreas Porto, Miguel Davison, Helen von Schulthess, Gustav K Huellner, Martin Stolzmann, Paul Veit-Haibach, Patrick Burger, Irene A |
author_sort | Gunzinger, Jeanne M |
collection | PubMed |
description | BACKGROUND: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acquisition variable-resonance image combination (MAVRIC SL) in comparison to conventional high-bandwidth techniques and in a second step showed the effect of artifact size on MRI-based attenuation correction (AC) with a simulation study. METHODS: Twenty-five patients with dental implants prospectively underwent a trimodality PET/CT/MRI examination after informed consent was obtained under the approval of the local ethics committee. A conventional 3D gradient-echo sequence (LAVA-Flex) commonly used for MRI-based AC of PET (acquisition time of 14 s), a T1w fast spin-echo sequence with high bandwidth (acquisition time of 3.2 min), as well as MAVRIC SL sequence without and with increased phase acceleration (MAVRIC, acquisition time of 6 min; MAVRIC-fast, acquisition time of 3.5 min) were applied. The absolute and relative reduction of the signal void artifact was calculated for each implant and tested for statistical significance using the Wilcoxon signed-rank test. The effect of artifact size on PET AC was simulated in one case with a large tumor in the oral cavity. The relative difference of the maximum standardized uptake value (SUV(max)) in the tumor was calculated for increasing artifact sizes centered over the second molar. RESULTS: The absolute reduction of signal void from LAVA-Flex sequences to the T1-weighted fast spin-echo (FSE) sequences was 416 mm(2) (range 4 to 2,010 mm(2)) to MAVRIC 481 mm(2) (range 12 to 2,288 mm(2)) and to MAVRIC-fast 486 mm(2) (range 39 to 2,209 mm(2)). The relative reduction in signal void was significantly improved for both MAVRIC and MAVRIC-fast compared to T1 FSE (−75%/−78% vs. −62%, p < 0.001 for both). The relative error for SUV(max) was negligible for artifacts of 0.5-cm diameter (−0.1%), but substantial for artifacts of 5.2-cm diameter (−33%). CONCLUSIONS: MAVRIC-fast could become useful for artifact reduction in PET/MR for patients with dental implants. This might improve diagnostic accuracy especially for patients with tumors in the oropharynx and substantially improve accuracy of PET quantification. |
format | Online Article Text |
id | pubmed-4545455 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-45454552015-08-26 Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI Gunzinger, Jeanne M Delso, Gaspar Boss, Andreas Porto, Miguel Davison, Helen von Schulthess, Gustav K Huellner, Martin Stolzmann, Paul Veit-Haibach, Patrick Burger, Irene A EJNMMI Phys Original Research BACKGROUND: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acquisition variable-resonance image combination (MAVRIC SL) in comparison to conventional high-bandwidth techniques and in a second step showed the effect of artifact size on MRI-based attenuation correction (AC) with a simulation study. METHODS: Twenty-five patients with dental implants prospectively underwent a trimodality PET/CT/MRI examination after informed consent was obtained under the approval of the local ethics committee. A conventional 3D gradient-echo sequence (LAVA-Flex) commonly used for MRI-based AC of PET (acquisition time of 14 s), a T1w fast spin-echo sequence with high bandwidth (acquisition time of 3.2 min), as well as MAVRIC SL sequence without and with increased phase acceleration (MAVRIC, acquisition time of 6 min; MAVRIC-fast, acquisition time of 3.5 min) were applied. The absolute and relative reduction of the signal void artifact was calculated for each implant and tested for statistical significance using the Wilcoxon signed-rank test. The effect of artifact size on PET AC was simulated in one case with a large tumor in the oral cavity. The relative difference of the maximum standardized uptake value (SUV(max)) in the tumor was calculated for increasing artifact sizes centered over the second molar. RESULTS: The absolute reduction of signal void from LAVA-Flex sequences to the T1-weighted fast spin-echo (FSE) sequences was 416 mm(2) (range 4 to 2,010 mm(2)) to MAVRIC 481 mm(2) (range 12 to 2,288 mm(2)) and to MAVRIC-fast 486 mm(2) (range 39 to 2,209 mm(2)). The relative reduction in signal void was significantly improved for both MAVRIC and MAVRIC-fast compared to T1 FSE (−75%/−78% vs. −62%, p < 0.001 for both). The relative error for SUV(max) was negligible for artifacts of 0.5-cm diameter (−0.1%), but substantial for artifacts of 5.2-cm diameter (−33%). CONCLUSIONS: MAVRIC-fast could become useful for artifact reduction in PET/MR for patients with dental implants. This might improve diagnostic accuracy especially for patients with tumors in the oropharynx and substantially improve accuracy of PET quantification. Springer International Publishing 2014-12-20 /pmc/articles/PMC4545455/ /pubmed/26501460 http://dx.doi.org/10.1186/s40658-014-0102-z Text en © Gunzinger et al; licensee Springer. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Original Research Gunzinger, Jeanne M Delso, Gaspar Boss, Andreas Porto, Miguel Davison, Helen von Schulthess, Gustav K Huellner, Martin Stolzmann, Paul Veit-Haibach, Patrick Burger, Irene A Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI |
title | Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI |
title_full | Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI |
title_fullStr | Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI |
title_full_unstemmed | Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI |
title_short | Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI |
title_sort | metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid pet/mri |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4545455/ https://www.ncbi.nlm.nih.gov/pubmed/26501460 http://dx.doi.org/10.1186/s40658-014-0102-z |
work_keys_str_mv | AT gunzingerjeannem metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT delsogaspar metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT bossandreas metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT portomiguel metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT davisonhelen metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT vonschulthessgustavk metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT huellnermartin metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT stolzmannpaul metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT veithaibachpatrick metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri AT burgerirenea metalartifactreductioninpatientswithdentalimplantsusingmultispectralthreedimensionaldataacquisitionforhybridpetmri |