Cargando…

Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study

BACKGROUND: Transverse sinus stenosis (TSS) is common among patients with cerebral venous sinus thrombosis. No previous studies have reported on double-track sign detected on axial Gd-enhanced T1WI in TSS. This study aimed to determine the sensitivity and specificity of the double-track sign in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, De-Sheng, Fu, Jue, Zhang, Yi, Xie, Chong, Wang, Xiao-Qing, Zhang, Yue, Yang, Jie, Li, Shi-Xu, Liu, Xiao-Bei, Wan, Zhi-Wen, Dong, Qiang, Guan, Yang-Tai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4546352/
https://www.ncbi.nlm.nih.gov/pubmed/26291452
http://dx.doi.org/10.1371/journal.pone.0135897
_version_ 1782386910218420224
author Zhu, De-Sheng
Fu, Jue
Zhang, Yi
Xie, Chong
Wang, Xiao-Qing
Zhang, Yue
Yang, Jie
Li, Shi-Xu
Liu, Xiao-Bei
Wan, Zhi-Wen
Dong, Qiang
Guan, Yang-Tai
author_facet Zhu, De-Sheng
Fu, Jue
Zhang, Yi
Xie, Chong
Wang, Xiao-Qing
Zhang, Yue
Yang, Jie
Li, Shi-Xu
Liu, Xiao-Bei
Wan, Zhi-Wen
Dong, Qiang
Guan, Yang-Tai
author_sort Zhu, De-Sheng
collection PubMed
description BACKGROUND: Transverse sinus stenosis (TSS) is common among patients with cerebral venous sinus thrombosis. No previous studies have reported on double-track sign detected on axial Gd-enhanced T1WI in TSS. This study aimed to determine the sensitivity and specificity of the double-track sign in the detection of TSS. METHODS: We retrospectively reviewed medical records of 383 patients with transverse sinus thrombosis (TST) and 30 patients with normal transverse sinus from 5 participating hospitals in china from January 2008 to June 2014. 167 feasible transverse sinuses included in this study were categorized into TSS (n = 76), transverse sinus occlusion (TSO) (n = 52) and transverse sinus normal (TSN) groups (n = 39) according to imaging diagnosis on digital subtraction angiography (DSA) or magnetic resonance venography (MRV). Double-track sign on axial Gd-enhanced T1WI was compared among the three groups. Sensitivity and specificity of double-track sign in detection of TSS were calculated, with final imaging diagnosis of TSS on DSA or MRV as the reference standard. RESULTS: Of 383 patients with TST recruited over a 6.5-year period, 128 patients were enrolled in the study, 255 patients were excluded because of insufficient clinical data, imaging finding and delay time, and 30 matched patients with normal transverse sinus were enrolled in the control group. Therefore, double-track sign assessment was conducted in 167 available transverse sinuses of 158 patients. Of the 76 sinuses in TSS group, 51 had double-track sign. Of the other 91 sinuses in TSO and TSN groups, 3 had a false-positive double-track sign. Thus, double-track sign on axial Gd-enhanced T1WI was 67.1% (95% CI 55.3–77.2) sensitive and 96.7% (95% CI 89.9–99.1) specific for detection of TSS. CONCLUSIONS: The double-track sign on axial Gd-enhanced T1WI is highly specific and moderate sensitive for detection of TSS. Nevertheless, it could be a direct sign and might provide an early clue for TSS.
format Online
Article
Text
id pubmed-4546352
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45463522015-08-26 Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study Zhu, De-Sheng Fu, Jue Zhang, Yi Xie, Chong Wang, Xiao-Qing Zhang, Yue Yang, Jie Li, Shi-Xu Liu, Xiao-Bei Wan, Zhi-Wen Dong, Qiang Guan, Yang-Tai PLoS One Research Article BACKGROUND: Transverse sinus stenosis (TSS) is common among patients with cerebral venous sinus thrombosis. No previous studies have reported on double-track sign detected on axial Gd-enhanced T1WI in TSS. This study aimed to determine the sensitivity and specificity of the double-track sign in the detection of TSS. METHODS: We retrospectively reviewed medical records of 383 patients with transverse sinus thrombosis (TST) and 30 patients with normal transverse sinus from 5 participating hospitals in china from January 2008 to June 2014. 167 feasible transverse sinuses included in this study were categorized into TSS (n = 76), transverse sinus occlusion (TSO) (n = 52) and transverse sinus normal (TSN) groups (n = 39) according to imaging diagnosis on digital subtraction angiography (DSA) or magnetic resonance venography (MRV). Double-track sign on axial Gd-enhanced T1WI was compared among the three groups. Sensitivity and specificity of double-track sign in detection of TSS were calculated, with final imaging diagnosis of TSS on DSA or MRV as the reference standard. RESULTS: Of 383 patients with TST recruited over a 6.5-year period, 128 patients were enrolled in the study, 255 patients were excluded because of insufficient clinical data, imaging finding and delay time, and 30 matched patients with normal transverse sinus were enrolled in the control group. Therefore, double-track sign assessment was conducted in 167 available transverse sinuses of 158 patients. Of the 76 sinuses in TSS group, 51 had double-track sign. Of the other 91 sinuses in TSO and TSN groups, 3 had a false-positive double-track sign. Thus, double-track sign on axial Gd-enhanced T1WI was 67.1% (95% CI 55.3–77.2) sensitive and 96.7% (95% CI 89.9–99.1) specific for detection of TSS. CONCLUSIONS: The double-track sign on axial Gd-enhanced T1WI is highly specific and moderate sensitive for detection of TSS. Nevertheless, it could be a direct sign and might provide an early clue for TSS. Public Library of Science 2015-08-20 /pmc/articles/PMC4546352/ /pubmed/26291452 http://dx.doi.org/10.1371/journal.pone.0135897 Text en © 2015 Zhu et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Zhu, De-Sheng
Fu, Jue
Zhang, Yi
Xie, Chong
Wang, Xiao-Qing
Zhang, Yue
Yang, Jie
Li, Shi-Xu
Liu, Xiao-Bei
Wan, Zhi-Wen
Dong, Qiang
Guan, Yang-Tai
Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study
title Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study
title_full Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study
title_fullStr Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study
title_full_unstemmed Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study
title_short Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study
title_sort sensitivity and specificity of double-track sign in the detection of transverse sinus stenosis: a multicenter retrospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4546352/
https://www.ncbi.nlm.nih.gov/pubmed/26291452
http://dx.doi.org/10.1371/journal.pone.0135897
work_keys_str_mv AT zhudesheng sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT fujue sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT zhangyi sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT xiechong sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT wangxiaoqing sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT zhangyue sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT yangjie sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT lishixu sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT liuxiaobei sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT wanzhiwen sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT dongqiang sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy
AT guanyangtai sensitivityandspecificityofdoubletracksigninthedetectionoftransversesinusstenosisamulticenterretrospectivestudy