Cargando…
A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas
BACKGROUND: To describe one modified method of having machine-independent removal of 5,000 centistokes silicone oil through 23-gauge trocar-cannulas. METHODS: Consecutive patients with silicone oil tamponade for more than four months and with complete retinal reattachment were included. Two 23-gauge...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4549089/ https://www.ncbi.nlm.nih.gov/pubmed/26303943 http://dx.doi.org/10.1186/s12886-015-0103-2 |
_version_ | 1782387267257499648 |
---|---|
author | Zhang, Zhaotian Wei, Yantao Jiang, Xintong Qiu, Suo Zhang, Shaochong |
author_facet | Zhang, Zhaotian Wei, Yantao Jiang, Xintong Qiu, Suo Zhang, Shaochong |
author_sort | Zhang, Zhaotian |
collection | PubMed |
description | BACKGROUND: To describe one modified method of having machine-independent removal of 5,000 centistokes silicone oil through 23-gauge trocar-cannulas. METHODS: Consecutive patients with silicone oil tamponade for more than four months and with complete retinal reattachment were included. Two 23-gauge trocars were used to make sclerotomies while the microcannulas remained in situ for intravitreous infusion and silicone oil drainage. A short section of infusion tube was connected with a 10 ml syringe’s needle adapter. The other side was attached to the conjunctiva surface and covered the cannula’s cap inside to form a closed space for silicone oil drainage. The main outcomes were duration for complete removal of silicone oil and intra- and postoperative complications. RESULT: There were totally twenty cases (20 eyes) included. The mean time for draining out the silicone oil was 4.54 ± 0.78 minutes. Intraoperatively, flute needle was introduced additionally in seven cases to achieve complete removal. No cases experienced postoperative visual acuity deterioration or refractory hypotony. No significant residual oil bubbles were observed. No retinal redetachment occurred throughout the follow-ups. CONCLUSION: The modified method of using an infusion tube and 23-gauge trocar-cannulas can achieve quick and complete removal of high viscosity silicone oil. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12886-015-0103-2) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4549089 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45490892015-08-26 A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas Zhang, Zhaotian Wei, Yantao Jiang, Xintong Qiu, Suo Zhang, Shaochong BMC Ophthalmol Technical Advance BACKGROUND: To describe one modified method of having machine-independent removal of 5,000 centistokes silicone oil through 23-gauge trocar-cannulas. METHODS: Consecutive patients with silicone oil tamponade for more than four months and with complete retinal reattachment were included. Two 23-gauge trocars were used to make sclerotomies while the microcannulas remained in situ for intravitreous infusion and silicone oil drainage. A short section of infusion tube was connected with a 10 ml syringe’s needle adapter. The other side was attached to the conjunctiva surface and covered the cannula’s cap inside to form a closed space for silicone oil drainage. The main outcomes were duration for complete removal of silicone oil and intra- and postoperative complications. RESULT: There were totally twenty cases (20 eyes) included. The mean time for draining out the silicone oil was 4.54 ± 0.78 minutes. Intraoperatively, flute needle was introduced additionally in seven cases to achieve complete removal. No cases experienced postoperative visual acuity deterioration or refractory hypotony. No significant residual oil bubbles were observed. No retinal redetachment occurred throughout the follow-ups. CONCLUSION: The modified method of using an infusion tube and 23-gauge trocar-cannulas can achieve quick and complete removal of high viscosity silicone oil. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12886-015-0103-2) contains supplementary material, which is available to authorized users. BioMed Central 2015-08-25 /pmc/articles/PMC4549089/ /pubmed/26303943 http://dx.doi.org/10.1186/s12886-015-0103-2 Text en © Zhang et al. 2015 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Technical Advance Zhang, Zhaotian Wei, Yantao Jiang, Xintong Qiu, Suo Zhang, Shaochong A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
title | A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
title_full | A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
title_fullStr | A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
title_full_unstemmed | A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
title_short | A machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
title_sort | machine-independent method to have active removal of 5,000 centistokes silicone oil using plastic infusion tube and 23-gauge microcannulas |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4549089/ https://www.ncbi.nlm.nih.gov/pubmed/26303943 http://dx.doi.org/10.1186/s12886-015-0103-2 |
work_keys_str_mv | AT zhangzhaotian amachineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT weiyantao amachineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT jiangxintong amachineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT qiusuo amachineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT zhangshaochong amachineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT zhangzhaotian machineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT weiyantao machineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT jiangxintong machineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT qiusuo machineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas AT zhangshaochong machineindependentmethodtohaveactiveremovalof5000centistokessiliconeoilusingplasticinfusiontubeand23gaugemicrocannulas |