Cargando…

Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants

OBJECTIVE: To compare the use of a generic molecular assay to ‘standard’ investigations used to assist the diagnosis of late onset bacterial sepsis in very low birth weight infants (VLBW, <1500g). METHODS: VLBW infants, greater than 48 hours of age, who were clinically suspected to have sepsis we...

Descripción completa

Detalles Bibliográficos
Autores principales: Davis, Jonathan, Christie, Sharon, Fairley, Derek, Coyle, Peter, Tubman, Richard, Shields, Michael D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4549273/
https://www.ncbi.nlm.nih.gov/pubmed/26305781
http://dx.doi.org/10.1371/journal.pone.0136472
_version_ 1782387291001454592
author Davis, Jonathan
Christie, Sharon
Fairley, Derek
Coyle, Peter
Tubman, Richard
Shields, Michael D.
author_facet Davis, Jonathan
Christie, Sharon
Fairley, Derek
Coyle, Peter
Tubman, Richard
Shields, Michael D.
author_sort Davis, Jonathan
collection PubMed
description OBJECTIVE: To compare the use of a generic molecular assay to ‘standard’ investigations used to assist the diagnosis of late onset bacterial sepsis in very low birth weight infants (VLBW, <1500g). METHODS: VLBW infants, greater than 48 hours of age, who were clinically suspected to have sepsis were investigated using standard tests (full blood count, C-reactive protein (at presentation) and blood culture), in addition, blood was taken for a universal molecular assay (16S rRNA reverse transcriptase PCR) for comparison. Clinical data were recorded during the suspected infection episode. A validated sepsis score (NEO-KISS) was used to retrospectively determine the presence of sepsis (independent of blood culture). The performance of each of the tests were compared by sensitivity, specificity, positive/negative likihood ratios (+/-LR) and postive/negative predictive values (PPV/NPV). RESULTS: Sixty-five babies with suspected clinical sepsis were prospectively included. The performance indicators are presented with 95% confidence limits. For the detection of bacteria, blood culture had sensitivity of 0.57 (0.34–0.78), specificity of 0.45 (0.30–0.61); +LR of 1.05 (0.66–1.66) and—LR of 0.94 (0.52–1.7); PPV of 33.3 (18.56–50.97) and NPV of 68.97 (49.17–87.72). Serum CRP had sensitivity of 0.92 (0.64–1) and specificity of 0.36 (0.17–0.59); +LR of 1.45 (1–2.1) and-LR of 0.21 (0.03–1.5); PPV of 44.46 (26.6–66.6) and NPV of 88.9 (51.8–99.7). The universal molecular assay had sensitivity of 0.76 (0.53–0.92), specificity of 0.95 (0.85–0.99); +LR of 16.8 (4.2–66.3) and-LR of 0.25 (0.1–0.5); PPV of 88.9 (65.3–98.6) and NPV of 89.4 (76.9–96.5). CONCLUSIONS: In VLBW infants this universal molecular assay performed better in the diagnosis of late onset sepsis (LOS) than blood culture and CRP. Further development is required to explore and improve the performance of the assay in real-time diagnosis.
format Online
Article
Text
id pubmed-4549273
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45492732015-09-01 Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants Davis, Jonathan Christie, Sharon Fairley, Derek Coyle, Peter Tubman, Richard Shields, Michael D. PLoS One Research Article OBJECTIVE: To compare the use of a generic molecular assay to ‘standard’ investigations used to assist the diagnosis of late onset bacterial sepsis in very low birth weight infants (VLBW, <1500g). METHODS: VLBW infants, greater than 48 hours of age, who were clinically suspected to have sepsis were investigated using standard tests (full blood count, C-reactive protein (at presentation) and blood culture), in addition, blood was taken for a universal molecular assay (16S rRNA reverse transcriptase PCR) for comparison. Clinical data were recorded during the suspected infection episode. A validated sepsis score (NEO-KISS) was used to retrospectively determine the presence of sepsis (independent of blood culture). The performance of each of the tests were compared by sensitivity, specificity, positive/negative likihood ratios (+/-LR) and postive/negative predictive values (PPV/NPV). RESULTS: Sixty-five babies with suspected clinical sepsis were prospectively included. The performance indicators are presented with 95% confidence limits. For the detection of bacteria, blood culture had sensitivity of 0.57 (0.34–0.78), specificity of 0.45 (0.30–0.61); +LR of 1.05 (0.66–1.66) and—LR of 0.94 (0.52–1.7); PPV of 33.3 (18.56–50.97) and NPV of 68.97 (49.17–87.72). Serum CRP had sensitivity of 0.92 (0.64–1) and specificity of 0.36 (0.17–0.59); +LR of 1.45 (1–2.1) and-LR of 0.21 (0.03–1.5); PPV of 44.46 (26.6–66.6) and NPV of 88.9 (51.8–99.7). The universal molecular assay had sensitivity of 0.76 (0.53–0.92), specificity of 0.95 (0.85–0.99); +LR of 16.8 (4.2–66.3) and-LR of 0.25 (0.1–0.5); PPV of 88.9 (65.3–98.6) and NPV of 89.4 (76.9–96.5). CONCLUSIONS: In VLBW infants this universal molecular assay performed better in the diagnosis of late onset sepsis (LOS) than blood culture and CRP. Further development is required to explore and improve the performance of the assay in real-time diagnosis. Public Library of Science 2015-08-25 /pmc/articles/PMC4549273/ /pubmed/26305781 http://dx.doi.org/10.1371/journal.pone.0136472 Text en © 2015 Davis et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Davis, Jonathan
Christie, Sharon
Fairley, Derek
Coyle, Peter
Tubman, Richard
Shields, Michael D.
Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants
title Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants
title_full Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants
title_fullStr Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants
title_full_unstemmed Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants
title_short Performance of a Novel Molecular Method in the Diagnosis of Late-Onset Sepsis in Very Low Birth Weight Infants
title_sort performance of a novel molecular method in the diagnosis of late-onset sepsis in very low birth weight infants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4549273/
https://www.ncbi.nlm.nih.gov/pubmed/26305781
http://dx.doi.org/10.1371/journal.pone.0136472
work_keys_str_mv AT davisjonathan performanceofanovelmolecularmethodinthediagnosisoflateonsetsepsisinverylowbirthweightinfants
AT christiesharon performanceofanovelmolecularmethodinthediagnosisoflateonsetsepsisinverylowbirthweightinfants
AT fairleyderek performanceofanovelmolecularmethodinthediagnosisoflateonsetsepsisinverylowbirthweightinfants
AT coylepeter performanceofanovelmolecularmethodinthediagnosisoflateonsetsepsisinverylowbirthweightinfants
AT tubmanrichard performanceofanovelmolecularmethodinthediagnosisoflateonsetsepsisinverylowbirthweightinfants
AT shieldsmichaeld performanceofanovelmolecularmethodinthediagnosisoflateonsetsepsisinverylowbirthweightinfants