Cargando…

The Use of Filtered Radiometers for Radiance Measurement

A methodology for using a calibrated filter radiometer to measure and monitor the spectral radiance of calibration sources is described. An example is presented using the NIST calibration sphere source that is used to support the NASA Earth Observing remote-sensing program.

Detalles Bibliográficos
Autores principales: Parr, Albert C., Johnson, B. Carol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4551216/
https://www.ncbi.nlm.nih.gov/pubmed/26989597
http://dx.doi.org/10.6028/jres.116.018
_version_ 1782387544314347520
author Parr, Albert C.
Johnson, B. Carol
author_facet Parr, Albert C.
Johnson, B. Carol
author_sort Parr, Albert C.
collection PubMed
description A methodology for using a calibrated filter radiometer to measure and monitor the spectral radiance of calibration sources is described. An example is presented using the NIST calibration sphere source that is used to support the NASA Earth Observing remote-sensing program.
format Online
Article
Text
id pubmed-4551216
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-45512162016-03-17 The Use of Filtered Radiometers for Radiance Measurement Parr, Albert C. Johnson, B. Carol J Res Natl Inst Stand Technol Article A methodology for using a calibrated filter radiometer to measure and monitor the spectral radiance of calibration sources is described. An example is presented using the NIST calibration sphere source that is used to support the NASA Earth Observing remote-sensing program. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2011 2011-10-01 /pmc/articles/PMC4551216/ /pubmed/26989597 http://dx.doi.org/10.6028/jres.116.018 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Parr, Albert C.
Johnson, B. Carol
The Use of Filtered Radiometers for Radiance Measurement
title The Use of Filtered Radiometers for Radiance Measurement
title_full The Use of Filtered Radiometers for Radiance Measurement
title_fullStr The Use of Filtered Radiometers for Radiance Measurement
title_full_unstemmed The Use of Filtered Radiometers for Radiance Measurement
title_short The Use of Filtered Radiometers for Radiance Measurement
title_sort use of filtered radiometers for radiance measurement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4551216/
https://www.ncbi.nlm.nih.gov/pubmed/26989597
http://dx.doi.org/10.6028/jres.116.018
work_keys_str_mv AT parralbertc theuseoffilteredradiometersforradiancemeasurement
AT johnsonbcarol theuseoffilteredradiometersforradiancemeasurement
AT parralbertc useoffilteredradiometersforradiancemeasurement
AT johnsonbcarol useoffilteredradiometersforradiancemeasurement