Cargando…
Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification
PURPOSE: Comparison of imaging measurement devices in the absence of a gold-standard comparator remains a vexing problem; especially in scenarios where multiple, non-paired, replicated measurements occur, as in image-guided radiotherapy (IGRT). As the number of commercially available IGRT presents a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4551570/ https://www.ncbi.nlm.nih.gov/pubmed/26310853 http://dx.doi.org/10.1186/s12880-015-0074-z |
_version_ | 1782387590151798784 |
---|---|
author | Roy, Anuradha Fuller, Clifton D. Rosenthal, David I. Thomas Jr., Charles R. |
author_facet | Roy, Anuradha Fuller, Clifton D. Rosenthal, David I. Thomas Jr., Charles R. |
author_sort | Roy, Anuradha |
collection | PubMed |
description | PURPOSE: Comparison of imaging measurement devices in the absence of a gold-standard comparator remains a vexing problem; especially in scenarios where multiple, non-paired, replicated measurements occur, as in image-guided radiotherapy (IGRT). As the number of commercially available IGRT presents a challenge to determine whether different IGRT methods may be used interchangeably, an unmet need conceptually parsimonious and statistically robust method to evaluate the agreement between two methods with replicated observations. Consequently, we sought to determine, using an previously reported head and neck positional verification dataset, the feasibility and utility of a Comparison of Measurement Methods with the Mixed Effects Procedure Accounting for Replicated Evaluations (COM(3)PARE), a unified conceptual schema and analytic algorithm based upon Roy’s linear mixed effects (LME) model with Kronecker product covariance structure in a doubly multivariate set-up, for IGRT method comparison. METHODS: An anonymized dataset consisting of 100 paired coordinate (X/ measurements from a sequential series of head and neck cancer patients imaged near-simultaneously with cone beam CT (CBCT) and kilovoltage X-ray (KVX) imaging was used for model implementation. Software-suggested CBCT and KVX shifts for the lateral (X), vertical (Y) and longitudinal (Z) dimensions were evaluated for bias, inter-method (between-subject variation), intra-method (within-subject variation), and overall agreement using with a script implementing COM(3)PARE with the MIXED procedure of the statistical software package SAS (SAS Institute, Cary, NC, USA). RESULTS: COM(3)PARE showed statistically significant bias agreement and difference in inter-method between CBCT and KVX was observed in the Z-axis (both p − value<0.01). Intra-method and overall agreement differences were noted as statistically significant for both the X- and Z-axes (all p − value<0.01). Using pre-specified criteria, based on intra-method agreement, CBCT was deemed preferable for X-axis positional verification, with KVX preferred for superoinferior alignment. CONCLUSIONS: The COM(3)PARE methodology was validated as feasible and useful in this pilot head and neck cancer positional verification dataset. COM(3)PARE represents a flexible and robust standardized analytic methodology for IGRT comparison. The implemented SAS script is included to encourage other groups to implement COM(3)PARE in other anatomic sites or IGRT platforms. |
format | Online Article Text |
id | pubmed-4551570 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45515702015-08-29 Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification Roy, Anuradha Fuller, Clifton D. Rosenthal, David I. Thomas Jr., Charles R. BMC Med Imaging Technical Advance PURPOSE: Comparison of imaging measurement devices in the absence of a gold-standard comparator remains a vexing problem; especially in scenarios where multiple, non-paired, replicated measurements occur, as in image-guided radiotherapy (IGRT). As the number of commercially available IGRT presents a challenge to determine whether different IGRT methods may be used interchangeably, an unmet need conceptually parsimonious and statistically robust method to evaluate the agreement between two methods with replicated observations. Consequently, we sought to determine, using an previously reported head and neck positional verification dataset, the feasibility and utility of a Comparison of Measurement Methods with the Mixed Effects Procedure Accounting for Replicated Evaluations (COM(3)PARE), a unified conceptual schema and analytic algorithm based upon Roy’s linear mixed effects (LME) model with Kronecker product covariance structure in a doubly multivariate set-up, for IGRT method comparison. METHODS: An anonymized dataset consisting of 100 paired coordinate (X/ measurements from a sequential series of head and neck cancer patients imaged near-simultaneously with cone beam CT (CBCT) and kilovoltage X-ray (KVX) imaging was used for model implementation. Software-suggested CBCT and KVX shifts for the lateral (X), vertical (Y) and longitudinal (Z) dimensions were evaluated for bias, inter-method (between-subject variation), intra-method (within-subject variation), and overall agreement using with a script implementing COM(3)PARE with the MIXED procedure of the statistical software package SAS (SAS Institute, Cary, NC, USA). RESULTS: COM(3)PARE showed statistically significant bias agreement and difference in inter-method between CBCT and KVX was observed in the Z-axis (both p − value<0.01). Intra-method and overall agreement differences were noted as statistically significant for both the X- and Z-axes (all p − value<0.01). Using pre-specified criteria, based on intra-method agreement, CBCT was deemed preferable for X-axis positional verification, with KVX preferred for superoinferior alignment. CONCLUSIONS: The COM(3)PARE methodology was validated as feasible and useful in this pilot head and neck cancer positional verification dataset. COM(3)PARE represents a flexible and robust standardized analytic methodology for IGRT comparison. The implemented SAS script is included to encourage other groups to implement COM(3)PARE in other anatomic sites or IGRT platforms. BioMed Central 2015-08-28 /pmc/articles/PMC4551570/ /pubmed/26310853 http://dx.doi.org/10.1186/s12880-015-0074-z Text en © Roy et al. 2015 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Technical Advance Roy, Anuradha Fuller, Clifton D. Rosenthal, David I. Thomas Jr., Charles R. Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification |
title | Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification |
title_full | Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification |
title_fullStr | Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification |
title_full_unstemmed | Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification |
title_short | Comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (COM(3)PARE): method comparison algorithm implementation for head and neck IGRT positional verification |
title_sort | comparison of measurement methods with a mixed effects procedure accounting for replicated evaluations (com(3)pare): method comparison algorithm implementation for head and neck igrt positional verification |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4551570/ https://www.ncbi.nlm.nih.gov/pubmed/26310853 http://dx.doi.org/10.1186/s12880-015-0074-z |
work_keys_str_mv | AT royanuradha comparisonofmeasurementmethodswithamixedeffectsprocedureaccountingforreplicatedevaluationscom3paremethodcomparisonalgorithmimplementationforheadandneckigrtpositionalverification AT fullercliftond comparisonofmeasurementmethodswithamixedeffectsprocedureaccountingforreplicatedevaluationscom3paremethodcomparisonalgorithmimplementationforheadandneckigrtpositionalverification AT rosenthaldavidi comparisonofmeasurementmethodswithamixedeffectsprocedureaccountingforreplicatedevaluationscom3paremethodcomparisonalgorithmimplementationforheadandneckigrtpositionalverification AT thomasjrcharlesr comparisonofmeasurementmethodswithamixedeffectsprocedureaccountingforreplicatedevaluationscom3paremethodcomparisonalgorithmimplementationforheadandneckigrtpositionalverification |