Cargando…

NIST Ionization Chamber “A” Sample-Height Corrections

For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber “A” (PIC “A”) to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source...

Descripción completa

Detalles Bibliográficos
Autor principal: Fitzgerald, Ryan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4553863/
https://www.ncbi.nlm.nih.gov/pubmed/26900515
http://dx.doi.org/10.6028/jres.117.003
_version_ 1782387963621015552
author Fitzgerald, Ryan
author_facet Fitzgerald, Ryan
author_sort Fitzgerald, Ryan
collection PubMed
description For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber “A” (PIC “A”) to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source positioning ring over time. The temporal change in the holder caused an error in the source-height within the chamber, which was thought to be invariant. This unaccounted-for height change caused a change in the detector response and thus a relative error in measured activity on the order of 10(−5) to 10(−3) per year, depending on the radionuclide. The drifting detector response affected calibration factors and half-life determinations. After discovering the problem, we carried out historic research and new sensitivity tests. As a result, we have created a quantitative model of the effect and have used that model to estimate corrections to some of the past measurement results from PIC “A”. In this paper we report the details and results of that model. Meanwhile, we have fixed the positioning ring and are recalibrating the detector using primary measurement methods and enhanced quality control measures.
format Online
Article
Text
id pubmed-4553863
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-45538632016-02-19 NIST Ionization Chamber “A” Sample-Height Corrections Fitzgerald, Ryan J Res Natl Inst Stand Technol Article For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber “A” (PIC “A”) to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source positioning ring over time. The temporal change in the holder caused an error in the source-height within the chamber, which was thought to be invariant. This unaccounted-for height change caused a change in the detector response and thus a relative error in measured activity on the order of 10(−5) to 10(−3) per year, depending on the radionuclide. The drifting detector response affected calibration factors and half-life determinations. After discovering the problem, we carried out historic research and new sensitivity tests. As a result, we have created a quantitative model of the effect and have used that model to estimate corrections to some of the past measurement results from PIC “A”. In this paper we report the details and results of that model. Meanwhile, we have fixed the positioning ring and are recalibrating the detector using primary measurement methods and enhanced quality control measures. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 2012-02-02 /pmc/articles/PMC4553863/ /pubmed/26900515 http://dx.doi.org/10.6028/jres.117.003 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Fitzgerald, Ryan
NIST Ionization Chamber “A” Sample-Height Corrections
title NIST Ionization Chamber “A” Sample-Height Corrections
title_full NIST Ionization Chamber “A” Sample-Height Corrections
title_fullStr NIST Ionization Chamber “A” Sample-Height Corrections
title_full_unstemmed NIST Ionization Chamber “A” Sample-Height Corrections
title_short NIST Ionization Chamber “A” Sample-Height Corrections
title_sort nist ionization chamber “a” sample-height corrections
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4553863/
https://www.ncbi.nlm.nih.gov/pubmed/26900515
http://dx.doi.org/10.6028/jres.117.003
work_keys_str_mv AT fitzgeraldryan nistionizationchamberasampleheightcorrections