Cargando…
The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes
BACKGROUND: Premature rupture of membranes (PROM) is a common obstetric issue during pregnancy which might lead to serious fetal or maternal problems. Therefore, an appropriate diagnosis and management of PROM are of significant importance in patients. OBJECTIVE: The aim of this study was to determi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Research and Clinical Center for Infertility
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4555055/ https://www.ncbi.nlm.nih.gov/pubmed/26330850 |
_version_ | 1782388124207284224 |
---|---|
author | Khooshideh, Maryam Radi, Vida Hosseini, Reihaneh Hosseini, Ladan |
author_facet | Khooshideh, Maryam Radi, Vida Hosseini, Reihaneh Hosseini, Ladan |
author_sort | Khooshideh, Maryam |
collection | PubMed |
description | BACKGROUND: Premature rupture of membranes (PROM) is a common obstetric issue during pregnancy which might lead to serious fetal or maternal problems. Therefore, an appropriate diagnosis and management of PROM are of significant importance in patients. OBJECTIVE: The aim of this study was to determine the accuracy of placental alpha microglobuline-1 (PAMG-1) test in PROM diagnosis and compare this diagnostic method with other standard tests in diagnosis of PROM. MATERIALS AND METHODS: In this prospective diagnostic accuracy study, patients with symptoms of membrane rupture in 16-39 weeks of gestation were involved. Three tests including Fern, Nitrazine and PAMG-1 were performed at the same time. RESULTS: PROM was confirmed in 86 patients out of 100. The sensitivity and specificity were respectively 81.3% and 100% for Fern test, 93% and 92.8% for Nitrazine test, 98.9% and 92.8% for PAMG-1 test. PAMG-1 test showed higher sensitivity (98.9% with p<0.001) and accuracy (98%) compared with conventional tests. Although PAMG-1showed a lower positive predictive value (PPV) compared to conventional tests such as Fern test (100%), it was shown to be more accurate. CONCLUSION: The accuracy of PAMG-1 test was superior to both Fern and Nitrazine test in PROM diagnosis. |
format | Online Article Text |
id | pubmed-4555055 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Research and Clinical Center for Infertility |
record_format | MEDLINE/PubMed |
spelling | pubmed-45550552015-09-01 The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes Khooshideh, Maryam Radi, Vida Hosseini, Reihaneh Hosseini, Ladan Iran J Reprod Med Original Article BACKGROUND: Premature rupture of membranes (PROM) is a common obstetric issue during pregnancy which might lead to serious fetal or maternal problems. Therefore, an appropriate diagnosis and management of PROM are of significant importance in patients. OBJECTIVE: The aim of this study was to determine the accuracy of placental alpha microglobuline-1 (PAMG-1) test in PROM diagnosis and compare this diagnostic method with other standard tests in diagnosis of PROM. MATERIALS AND METHODS: In this prospective diagnostic accuracy study, patients with symptoms of membrane rupture in 16-39 weeks of gestation were involved. Three tests including Fern, Nitrazine and PAMG-1 were performed at the same time. RESULTS: PROM was confirmed in 86 patients out of 100. The sensitivity and specificity were respectively 81.3% and 100% for Fern test, 93% and 92.8% for Nitrazine test, 98.9% and 92.8% for PAMG-1 test. PAMG-1 test showed higher sensitivity (98.9% with p<0.001) and accuracy (98%) compared with conventional tests. Although PAMG-1showed a lower positive predictive value (PPV) compared to conventional tests such as Fern test (100%), it was shown to be more accurate. CONCLUSION: The accuracy of PAMG-1 test was superior to both Fern and Nitrazine test in PROM diagnosis. Research and Clinical Center for Infertility 2015-06 /pmc/articles/PMC4555055/ /pubmed/26330850 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Khooshideh, Maryam Radi, Vida Hosseini, Reihaneh Hosseini, Ladan The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
title | The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
title_full | The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
title_fullStr | The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
title_full_unstemmed | The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
title_short | The accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
title_sort | accuracy of placental alpha-microglobuline-1 test in diagnosis of premature rupture of the membranes |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4555055/ https://www.ncbi.nlm.nih.gov/pubmed/26330850 |
work_keys_str_mv | AT khooshidehmaryam theaccuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT radivida theaccuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT hosseinireihaneh theaccuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT hosseiniladan theaccuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT khooshidehmaryam accuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT radivida accuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT hosseinireihaneh accuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes AT hosseiniladan accuracyofplacentalalphamicroglobuline1testindiagnosisofprematureruptureofthemembranes |