Cargando…
Clinical utility of platinum chromium bare-metal stents in coronary heart disease
Coronary stents represent a key development for the treatment of obstructive coronary artery disease since the introduction of percutaneous coronary intervention. While drug-eluting stents gained wide acceptance in contemporary percutaneous coronary intervention practice, further developments in bar...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4556305/ https://www.ncbi.nlm.nih.gov/pubmed/26345228 http://dx.doi.org/10.2147/MDER.S69415 |
_version_ | 1782388331329355776 |
---|---|
author | Jorge, Claudia Dubois, Christophe |
author_facet | Jorge, Claudia Dubois, Christophe |
author_sort | Jorge, Claudia |
collection | PubMed |
description | Coronary stents represent a key development for the treatment of obstructive coronary artery disease since the introduction of percutaneous coronary intervention. While drug-eluting stents gained wide acceptance in contemporary percutaneous coronary intervention practice, further developments in bare-metal stents remain crucial for patients who are not candidates for drug-eluting stents, or to improve metallic platforms for drug elution. Initially, stent platforms used biologically inert stainless steel, restricting stent performance due to limitations in flexibility and strut thickness. Later, cobalt chromium stent alloys outperformed steel as the material of choice for stents, allowing latest generation stents to be designed with significantly thinner struts, while maintaining corrosion resistance and radial strength. Most recently, the introduction of the platinum chromium alloy refined stent architecture with thin struts, high radial strength, conformability, and improved radiopacity. This review will provide an overview of the novel platinum chromium bare-metal stent platforms available for coronary intervention. Mechanical properties, clinical utility, and device limitations will be summarized and put into perspective. |
format | Online Article Text |
id | pubmed-4556305 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-45563052015-09-04 Clinical utility of platinum chromium bare-metal stents in coronary heart disease Jorge, Claudia Dubois, Christophe Med Devices (Auckl) Review Coronary stents represent a key development for the treatment of obstructive coronary artery disease since the introduction of percutaneous coronary intervention. While drug-eluting stents gained wide acceptance in contemporary percutaneous coronary intervention practice, further developments in bare-metal stents remain crucial for patients who are not candidates for drug-eluting stents, or to improve metallic platforms for drug elution. Initially, stent platforms used biologically inert stainless steel, restricting stent performance due to limitations in flexibility and strut thickness. Later, cobalt chromium stent alloys outperformed steel as the material of choice for stents, allowing latest generation stents to be designed with significantly thinner struts, while maintaining corrosion resistance and radial strength. Most recently, the introduction of the platinum chromium alloy refined stent architecture with thin struts, high radial strength, conformability, and improved radiopacity. This review will provide an overview of the novel platinum chromium bare-metal stent platforms available for coronary intervention. Mechanical properties, clinical utility, and device limitations will be summarized and put into perspective. Dove Medical Press 2015-08-27 /pmc/articles/PMC4556305/ /pubmed/26345228 http://dx.doi.org/10.2147/MDER.S69415 Text en © 2015 Jorge and Dubois. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Review Jorge, Claudia Dubois, Christophe Clinical utility of platinum chromium bare-metal stents in coronary heart disease |
title | Clinical utility of platinum chromium bare-metal stents in coronary heart disease |
title_full | Clinical utility of platinum chromium bare-metal stents in coronary heart disease |
title_fullStr | Clinical utility of platinum chromium bare-metal stents in coronary heart disease |
title_full_unstemmed | Clinical utility of platinum chromium bare-metal stents in coronary heart disease |
title_short | Clinical utility of platinum chromium bare-metal stents in coronary heart disease |
title_sort | clinical utility of platinum chromium bare-metal stents in coronary heart disease |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4556305/ https://www.ncbi.nlm.nih.gov/pubmed/26345228 http://dx.doi.org/10.2147/MDER.S69415 |
work_keys_str_mv | AT jorgeclaudia clinicalutilityofplatinumchromiumbaremetalstentsincoronaryheartdisease AT duboischristophe clinicalutilityofplatinumchromiumbaremetalstentsincoronaryheartdisease |