Cargando…

Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors

PURPOSE: To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. METHODS: Detection results of 31 primary trachea and main bronchus t...

Descripción completa

Detalles Bibliográficos
Autores principales: Luo, Mingyue, Duan, Chaijie, Qiu, Jianping, Li, Wenru, Zhu, Dongyun, Cai, Wenli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4558050/
https://www.ncbi.nlm.nih.gov/pubmed/26332466
http://dx.doi.org/10.1371/journal.pone.0137329
_version_ 1782388565780463616
author Luo, Mingyue
Duan, Chaijie
Qiu, Jianping
Li, Wenru
Zhu, Dongyun
Cai, Wenli
author_facet Luo, Mingyue
Duan, Chaijie
Qiu, Jianping
Li, Wenru
Zhu, Dongyun
Cai, Wenli
author_sort Luo, Mingyue
collection PubMed
description PURPOSE: To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. METHODS: Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. RESULTS: Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm—56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm—68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without obvious enhancement, n = 1). CONCLUSION: MDCT and its MPR, VR and VB images have respective advantages and disadvantages. Their combination could complement to each other to accurately detect locations, natures (benignancy, malignancy or low malignancy), and quantities (extramural invasions, longitudinal involvements, extents of luminal stenoses, distances between main bronchus tumors and trachea carinae) of primary trachea and main bronchus tumors with crucial information for surgical treatment, are highly useful diagnostic methods for primary trachea and main bronchus tumors.
format Online
Article
Text
id pubmed-4558050
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45580502015-09-10 Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors Luo, Mingyue Duan, Chaijie Qiu, Jianping Li, Wenru Zhu, Dongyun Cai, Wenli PLoS One Research Article PURPOSE: To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. METHODS: Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. RESULTS: Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm—56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm—68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without obvious enhancement, n = 1). CONCLUSION: MDCT and its MPR, VR and VB images have respective advantages and disadvantages. Their combination could complement to each other to accurately detect locations, natures (benignancy, malignancy or low malignancy), and quantities (extramural invasions, longitudinal involvements, extents of luminal stenoses, distances between main bronchus tumors and trachea carinae) of primary trachea and main bronchus tumors with crucial information for surgical treatment, are highly useful diagnostic methods for primary trachea and main bronchus tumors. Public Library of Science 2015-09-02 /pmc/articles/PMC4558050/ /pubmed/26332466 http://dx.doi.org/10.1371/journal.pone.0137329 Text en © 2015 Luo et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Luo, Mingyue
Duan, Chaijie
Qiu, Jianping
Li, Wenru
Zhu, Dongyun
Cai, Wenli
Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors
title Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors
title_full Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors
title_fullStr Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors
title_full_unstemmed Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors
title_short Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors
title_sort diagnostic value of multidetector ct and its multiplanar reformation, volume rendering and virtual bronchoscopy postprocessing techniques for primary trachea and main bronchus tumors
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4558050/
https://www.ncbi.nlm.nih.gov/pubmed/26332466
http://dx.doi.org/10.1371/journal.pone.0137329
work_keys_str_mv AT luomingyue diagnosticvalueofmultidetectorctanditsmultiplanarreformationvolumerenderingandvirtualbronchoscopypostprocessingtechniquesforprimarytracheaandmainbronchustumors
AT duanchaijie diagnosticvalueofmultidetectorctanditsmultiplanarreformationvolumerenderingandvirtualbronchoscopypostprocessingtechniquesforprimarytracheaandmainbronchustumors
AT qiujianping diagnosticvalueofmultidetectorctanditsmultiplanarreformationvolumerenderingandvirtualbronchoscopypostprocessingtechniquesforprimarytracheaandmainbronchustumors
AT liwenru diagnosticvalueofmultidetectorctanditsmultiplanarreformationvolumerenderingandvirtualbronchoscopypostprocessingtechniquesforprimarytracheaandmainbronchustumors
AT zhudongyun diagnosticvalueofmultidetectorctanditsmultiplanarreformationvolumerenderingandvirtualbronchoscopypostprocessingtechniquesforprimarytracheaandmainbronchustumors
AT caiwenli diagnosticvalueofmultidetectorctanditsmultiplanarreformationvolumerenderingandvirtualbronchoscopypostprocessingtechniquesforprimarytracheaandmainbronchustumors