Cargando…

On the practical identifiability of a two-parameter model of pulmonary gas exchange

BACKGROUND: Successful application of mechanical ventilation as a life-saving therapy implies appropriate ventilator settings. Decision making is based on clinicians’ knowledge, but can be enhanced by mathematical models that determine the individual patient state by calculating parameters that are...

Descripción completa

Detalles Bibliográficos
Autores principales: Riedlinger, Axel, Kretschmer, Jörn, Möller, Knut
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4558761/
https://www.ncbi.nlm.nih.gov/pubmed/26337953
http://dx.doi.org/10.1186/s12938-015-0077-6
_version_ 1782388663639867392
author Riedlinger, Axel
Kretschmer, Jörn
Möller, Knut
author_facet Riedlinger, Axel
Kretschmer, Jörn
Möller, Knut
author_sort Riedlinger, Axel
collection PubMed
description BACKGROUND: Successful application of mechanical ventilation as a life-saving therapy implies appropriate ventilator settings. Decision making is based on clinicians’ knowledge, but can be enhanced by mathematical models that determine the individual patient state by calculating parameters that are not directly measurable. Evaluation of models may support the clinician to reach a defined treatment goal. Bedside applicability of mathematical models for decision support requires a robust identification of the model parameters with a minimum of measuring effort. The influence of appropriate data selection on the identification of a two-parameter model of pulmonary gas exchange was analyzed. METHODS: The model considers a shunt as well as ventilation-perfusion-mismatch to simulate a variety of pathologic pulmonary gas exchange states, i.e. different severities of pulmonary impairment. Synthetic patient data were generated by model simulation. To incorporate more realistic effects of measurement errors, the simulated data were corrupted with additive noise. In addition, real patient data retrieved from a patient data management system were used retrospectively to confirm the obtained findings. The model was identified to a wide range of different FiO(2) settings. Just one single measurement was used for parameter identification. Subsequently prediction performance was obtained by comparing the identified model predicted oxygen level in arterial blood either to exact data taken from simulations or patients measurements. RESULTS: Structural identifiability of the model using one single measurement for the identification process could be demonstrated. Minimum prediction error of blood oxygenation depends on blood gas level at the time of system identification i.e. the measurement situation. For severe pulmonary impairment, higher FiO(2) settings were required to achieve a better prediction capability compared to less impaired pulmonary states. Plausibility analysis with real patient data could confirm this finding. DISCUSSION AND CONCLUSIONS: Dependent on patients’ pulmonary state, the influence of ventilator settings (here FiO(2)) on model identification of the gas exchange model could be demonstrated. To maximize prediction accuracy i.e. to find the best individualized model with as few data as possible, best ranges of FiO(2)-settings for parameter identification were obtained. A less effort identification process, which depends on the pulmonary state, can be deduced from the results of this identifiability analysis.
format Online
Article
Text
id pubmed-4558761
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-45587612015-09-04 On the practical identifiability of a two-parameter model of pulmonary gas exchange Riedlinger, Axel Kretschmer, Jörn Möller, Knut Biomed Eng Online Research BACKGROUND: Successful application of mechanical ventilation as a life-saving therapy implies appropriate ventilator settings. Decision making is based on clinicians’ knowledge, but can be enhanced by mathematical models that determine the individual patient state by calculating parameters that are not directly measurable. Evaluation of models may support the clinician to reach a defined treatment goal. Bedside applicability of mathematical models for decision support requires a robust identification of the model parameters with a minimum of measuring effort. The influence of appropriate data selection on the identification of a two-parameter model of pulmonary gas exchange was analyzed. METHODS: The model considers a shunt as well as ventilation-perfusion-mismatch to simulate a variety of pathologic pulmonary gas exchange states, i.e. different severities of pulmonary impairment. Synthetic patient data were generated by model simulation. To incorporate more realistic effects of measurement errors, the simulated data were corrupted with additive noise. In addition, real patient data retrieved from a patient data management system were used retrospectively to confirm the obtained findings. The model was identified to a wide range of different FiO(2) settings. Just one single measurement was used for parameter identification. Subsequently prediction performance was obtained by comparing the identified model predicted oxygen level in arterial blood either to exact data taken from simulations or patients measurements. RESULTS: Structural identifiability of the model using one single measurement for the identification process could be demonstrated. Minimum prediction error of blood oxygenation depends on blood gas level at the time of system identification i.e. the measurement situation. For severe pulmonary impairment, higher FiO(2) settings were required to achieve a better prediction capability compared to less impaired pulmonary states. Plausibility analysis with real patient data could confirm this finding. DISCUSSION AND CONCLUSIONS: Dependent on patients’ pulmonary state, the influence of ventilator settings (here FiO(2)) on model identification of the gas exchange model could be demonstrated. To maximize prediction accuracy i.e. to find the best individualized model with as few data as possible, best ranges of FiO(2)-settings for parameter identification were obtained. A less effort identification process, which depends on the pulmonary state, can be deduced from the results of this identifiability analysis. BioMed Central 2015-09-04 /pmc/articles/PMC4558761/ /pubmed/26337953 http://dx.doi.org/10.1186/s12938-015-0077-6 Text en © Riedlinger et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Riedlinger, Axel
Kretschmer, Jörn
Möller, Knut
On the practical identifiability of a two-parameter model of pulmonary gas exchange
title On the practical identifiability of a two-parameter model of pulmonary gas exchange
title_full On the practical identifiability of a two-parameter model of pulmonary gas exchange
title_fullStr On the practical identifiability of a two-parameter model of pulmonary gas exchange
title_full_unstemmed On the practical identifiability of a two-parameter model of pulmonary gas exchange
title_short On the practical identifiability of a two-parameter model of pulmonary gas exchange
title_sort on the practical identifiability of a two-parameter model of pulmonary gas exchange
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4558761/
https://www.ncbi.nlm.nih.gov/pubmed/26337953
http://dx.doi.org/10.1186/s12938-015-0077-6
work_keys_str_mv AT riedlingeraxel onthepracticalidentifiabilityofatwoparametermodelofpulmonarygasexchange
AT kretschmerjorn onthepracticalidentifiabilityofatwoparametermodelofpulmonarygasexchange
AT mollerknut onthepracticalidentifiabilityofatwoparametermodelofpulmonarygasexchange