Cargando…

Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types

OBJECTIVE: The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. MATERIALS AND METH...

Descripción completa

Detalles Bibliográficos
Autores principales: Suh, Young Joo, Kim, Young Jin, Hong, Yoo Jin, Lee, Hye-Jeong, Hur, Jin, Im, Dong Jin, Kim, Yun Jung, Choi, Byoung Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4559772/
https://www.ncbi.nlm.nih.gov/pubmed/26356549
http://dx.doi.org/10.3348/kjr.2015.16.5.1012
_version_ 1782388831241109504
author Suh, Young Joo
Kim, Young Jin
Hong, Yoo Jin
Lee, Hye-Jeong
Hur, Jin
Im, Dong Jin
Kim, Yun Jung
Choi, Byoung Wook
author_facet Suh, Young Joo
Kim, Young Jin
Hong, Yoo Jin
Lee, Hye-Jeong
Hur, Jin
Im, Dong Jin
Kim, Yun Jung
Choi, Byoung Wook
author_sort Suh, Young Joo
collection PubMed
description OBJECTIVE: The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. MATERIALS AND METHODS: A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. RESULTS: The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2° in seven types of valves, 11.0° in On-X valves, and 15.5° in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). CONCLUSION: Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG.
format Online
Article
Text
id pubmed-4559772
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-45597722015-09-09 Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types Suh, Young Joo Kim, Young Jin Hong, Yoo Jin Lee, Hye-Jeong Hur, Jin Im, Dong Jin Kim, Yun Jung Choi, Byoung Wook Korean J Radiol Cardiovascular Imaging OBJECTIVE: The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. MATERIALS AND METHODS: A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. RESULTS: The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2° in seven types of valves, 11.0° in On-X valves, and 15.5° in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). CONCLUSION: Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG. The Korean Society of Radiology 2015 2015-08-21 /pmc/articles/PMC4559772/ /pubmed/26356549 http://dx.doi.org/10.3348/kjr.2015.16.5.1012 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Suh, Young Joo
Kim, Young Jin
Hong, Yoo Jin
Lee, Hye-Jeong
Hur, Jin
Im, Dong Jin
Kim, Yun Jung
Choi, Byoung Wook
Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
title Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
title_full Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
title_fullStr Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
title_full_unstemmed Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
title_short Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types
title_sort measurement of opening and closing angles of aortic valve prostheses in vivo using dual-source computed tomography: comparison with those of manufacturers' in 10 different types
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4559772/
https://www.ncbi.nlm.nih.gov/pubmed/26356549
http://dx.doi.org/10.3348/kjr.2015.16.5.1012
work_keys_str_mv AT suhyoungjoo measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT kimyoungjin measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT hongyoojin measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT leehyejeong measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT hurjin measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT imdongjin measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT kimyunjung measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes
AT choibyoungwook measurementofopeningandclosinganglesofaorticvalveprosthesesinvivousingdualsourcecomputedtomographycomparisonwiththoseofmanufacturersin10differenttypes