Cargando…
Can titanium mesh influence local recurrence management after implant-based breast reconstruction?
INTRODUCTION: TiLOOP(®) Bra is a permanent titanium-coated polypropylene mesh currently used in post-mastectomy breast reconstruction with implants. This mesh is generally presented as inducing low-grade inflammatory reactions, but only few reports focused on its possible side effects. In the case d...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4560729/ https://www.ncbi.nlm.nih.gov/pubmed/26361583 http://dx.doi.org/10.1186/s40064-015-1273-3 |
_version_ | 1782388949563473920 |
---|---|
author | Riggio, Egidio Chifu, Camelia Martelli, Gabriele Ferraris, Cristina |
author_facet | Riggio, Egidio Chifu, Camelia Martelli, Gabriele Ferraris, Cristina |
author_sort | Riggio, Egidio |
collection | PubMed |
description | INTRODUCTION: TiLOOP(®) Bra is a permanent titanium-coated polypropylene mesh currently used in post-mastectomy breast reconstruction with implants. This mesh is generally presented as inducing low-grade inflammatory reactions, but only few reports focused on its possible side effects. In the case described here, the use of the mesh led to minor clinical problems that needed to be clinically and surgically managed at the same time as a local relapse. CASE DESCRIPTION: A patient with high-grade ductal carcinoma in situ underwent primary surgery (nipple-sparing mastectomy and one-stage reconstruction using the TiLOOP(®) Bra mesh) and was subsequently referred for radiological and clinical investigation when various nodules became apparent during a follow-up physical examination. Prior to the histopathological proof, the diagnosis of local recurrence was complicated by the occurrence of an extensive granulomatous reaction in the fixation areas along with mild inflammatory changes scattered on the surface of the mesh. DISCUSSION AND EVALUATION: This case illustrates a side effect of titanium-coated permanent mesh in immediate implant-based reconstruction, i.e. the formation of granulomas in the inframammary fold, probably in the area where the mesh had been folded or fixed. We propose a safer technical approach to avoid the problem and a clinical management strategy for patients at high risk of local recurrence who develop granuloma-like nodules. CONCLUSIONS: A surgical technique is suggested to prevent granuloma formation. If, however, subcutaneous nodules that may be local recurrences do appear, they should not be interpreted by default as a granulomatous reaction, but should be fully investigated and possibly excised. |
format | Online Article Text |
id | pubmed-4560729 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-45607292015-09-10 Can titanium mesh influence local recurrence management after implant-based breast reconstruction? Riggio, Egidio Chifu, Camelia Martelli, Gabriele Ferraris, Cristina Springerplus Case Study INTRODUCTION: TiLOOP(®) Bra is a permanent titanium-coated polypropylene mesh currently used in post-mastectomy breast reconstruction with implants. This mesh is generally presented as inducing low-grade inflammatory reactions, but only few reports focused on its possible side effects. In the case described here, the use of the mesh led to minor clinical problems that needed to be clinically and surgically managed at the same time as a local relapse. CASE DESCRIPTION: A patient with high-grade ductal carcinoma in situ underwent primary surgery (nipple-sparing mastectomy and one-stage reconstruction using the TiLOOP(®) Bra mesh) and was subsequently referred for radiological and clinical investigation when various nodules became apparent during a follow-up physical examination. Prior to the histopathological proof, the diagnosis of local recurrence was complicated by the occurrence of an extensive granulomatous reaction in the fixation areas along with mild inflammatory changes scattered on the surface of the mesh. DISCUSSION AND EVALUATION: This case illustrates a side effect of titanium-coated permanent mesh in immediate implant-based reconstruction, i.e. the formation of granulomas in the inframammary fold, probably in the area where the mesh had been folded or fixed. We propose a safer technical approach to avoid the problem and a clinical management strategy for patients at high risk of local recurrence who develop granuloma-like nodules. CONCLUSIONS: A surgical technique is suggested to prevent granuloma formation. If, however, subcutaneous nodules that may be local recurrences do appear, they should not be interpreted by default as a granulomatous reaction, but should be fully investigated and possibly excised. Springer International Publishing 2015-09-04 /pmc/articles/PMC4560729/ /pubmed/26361583 http://dx.doi.org/10.1186/s40064-015-1273-3 Text en © Riggio et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Case Study Riggio, Egidio Chifu, Camelia Martelli, Gabriele Ferraris, Cristina Can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
title | Can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
title_full | Can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
title_fullStr | Can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
title_full_unstemmed | Can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
title_short | Can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
title_sort | can titanium mesh influence local recurrence management after implant-based breast reconstruction? |
topic | Case Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4560729/ https://www.ncbi.nlm.nih.gov/pubmed/26361583 http://dx.doi.org/10.1186/s40064-015-1273-3 |
work_keys_str_mv | AT riggioegidio cantitaniummeshinfluencelocalrecurrencemanagementafterimplantbasedbreastreconstruction AT chifucamelia cantitaniummeshinfluencelocalrecurrencemanagementafterimplantbasedbreastreconstruction AT martelligabriele cantitaniummeshinfluencelocalrecurrencemanagementafterimplantbasedbreastreconstruction AT ferrariscristina cantitaniummeshinfluencelocalrecurrencemanagementafterimplantbasedbreastreconstruction |