Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference

BACKGROUND: Due to complex pelvic geometry, percutaneous screw placement in the posterior acetabular column can pose a major challenge even for experienced surgeons. METHODS: The present study examined the preformed bone stock of the posterior acetabular column in 260 hemipelvises. Retrograde poster...

Descripción completa

Detalles Bibliográficos
Autores principales: Ochs, Bjoern Gunnar, Stuby, Fabian Maria, Stoeckle, Ulrich, Gonser, Christoph Emanuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4560873/
https://www.ncbi.nlm.nih.gov/pubmed/26341003
http://dx.doi.org/10.1186/s12891-015-0697-9
_version_ 1782388972277727232
author Ochs, Bjoern Gunnar
Stuby, Fabian Maria
Stoeckle, Ulrich
Gonser, Christoph Emanuel
author_facet Ochs, Bjoern Gunnar
Stuby, Fabian Maria
Stoeckle, Ulrich
Gonser, Christoph Emanuel
author_sort Ochs, Bjoern Gunnar
collection PubMed
description BACKGROUND: Due to complex pelvic geometry, percutaneous screw placement in the posterior acetabular column can pose a major challenge even for experienced surgeons. METHODS: The present study examined the preformed bone stock of the posterior acetabular column in 260 hemipelvises. Retrograde posterior column screws were virtually implanted using iPlan® CMF (BrainLAB AG, Feldkirchen, Germany); maximal implant length, maximal implant diameter and angles between the screw trajectories and the reference planes anterior pelvic plane as well as the midsagittal plane were assessed for gender-specific differences. RESULTS: The virtual analysis of the preformed bone stock column showed two constrictions of crucial clinical importance. These were located 49.6 ± 3.4 (41.0–60.2) mm (inferior margin of acetabulum) and 77.0 ± 5.6 (66.5–95.3) mm (centre of acetabulum) from the entry point of the implant in men and respectively 43.7 ± 2.3 (38.3–49.3) mm as well as 71.2 ± 3.5 (63.5–79.99) mm in women (men vs. women: p < 0.001). The entry point of the retrograde posterior column screw was located dorsal from the transition of the lower margin of the ischial tuberosity to ramus inferior pointing to the medial margin of the ischial tuberosity. In female patients, the entry point was located significantly closer to the medial margin of the ischial tuberosity. However, 7.3 mm screws can generally be used in men and women. The angle between the screw trajectory and the anterior pelvic plane in sagittal section was 14.0 ± 4.9 (2.5–28.6) °, the angle between the screw trajectory and the midsagittal plane in axial section was 31.1 ± 12.8 (1.5–77.9) ° and the angle between the screw trajectory and the midsagittal plane in coronal section was 8.4 ± 3.8 (1.5–20.0) °. For all angles, significant gender-specific differences were found (p < 0.001). CONCLUSION: Therefore, the anterior pelvic plane as well as the midsagittal plane can facilitate intraoperative orientation for retrograde posterior column screw placement considering gender-specific differences in preformed bone corridor, implant length as well as angles formed between screw trajectory and these reference planes.
format Online
Article
Text
id pubmed-4560873
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-45608732015-09-06 Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference Ochs, Bjoern Gunnar Stuby, Fabian Maria Stoeckle, Ulrich Gonser, Christoph Emanuel BMC Musculoskelet Disord Research Article BACKGROUND: Due to complex pelvic geometry, percutaneous screw placement in the posterior acetabular column can pose a major challenge even for experienced surgeons. METHODS: The present study examined the preformed bone stock of the posterior acetabular column in 260 hemipelvises. Retrograde posterior column screws were virtually implanted using iPlan® CMF (BrainLAB AG, Feldkirchen, Germany); maximal implant length, maximal implant diameter and angles between the screw trajectories and the reference planes anterior pelvic plane as well as the midsagittal plane were assessed for gender-specific differences. RESULTS: The virtual analysis of the preformed bone stock column showed two constrictions of crucial clinical importance. These were located 49.6 ± 3.4 (41.0–60.2) mm (inferior margin of acetabulum) and 77.0 ± 5.6 (66.5–95.3) mm (centre of acetabulum) from the entry point of the implant in men and respectively 43.7 ± 2.3 (38.3–49.3) mm as well as 71.2 ± 3.5 (63.5–79.99) mm in women (men vs. women: p < 0.001). The entry point of the retrograde posterior column screw was located dorsal from the transition of the lower margin of the ischial tuberosity to ramus inferior pointing to the medial margin of the ischial tuberosity. In female patients, the entry point was located significantly closer to the medial margin of the ischial tuberosity. However, 7.3 mm screws can generally be used in men and women. The angle between the screw trajectory and the anterior pelvic plane in sagittal section was 14.0 ± 4.9 (2.5–28.6) °, the angle between the screw trajectory and the midsagittal plane in axial section was 31.1 ± 12.8 (1.5–77.9) ° and the angle between the screw trajectory and the midsagittal plane in coronal section was 8.4 ± 3.8 (1.5–20.0) °. For all angles, significant gender-specific differences were found (p < 0.001). CONCLUSION: Therefore, the anterior pelvic plane as well as the midsagittal plane can facilitate intraoperative orientation for retrograde posterior column screw placement considering gender-specific differences in preformed bone corridor, implant length as well as angles formed between screw trajectory and these reference planes. BioMed Central 2015-09-04 /pmc/articles/PMC4560873/ /pubmed/26341003 http://dx.doi.org/10.1186/s12891-015-0697-9 Text en © Ochs et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Ochs, Bjoern Gunnar
Stuby, Fabian Maria
Stoeckle, Ulrich
Gonser, Christoph Emanuel
Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
title Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
title_full Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
title_fullStr Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
title_full_unstemmed Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
title_short Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
title_sort virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4560873/
https://www.ncbi.nlm.nih.gov/pubmed/26341003
http://dx.doi.org/10.1186/s12891-015-0697-9
work_keys_str_mv AT ochsbjoerngunnar virtualmappingof260threedimensionalhemipelvisestoanalysegenderspecificdifferencesinminimallyinvasiveretrogradelagscrewplacementintheposterioracetabularcolumnusingtheanteriorpelvicandmidsagittalplaneasreference
AT stubyfabianmaria virtualmappingof260threedimensionalhemipelvisestoanalysegenderspecificdifferencesinminimallyinvasiveretrogradelagscrewplacementintheposterioracetabularcolumnusingtheanteriorpelvicandmidsagittalplaneasreference
AT stoeckleulrich virtualmappingof260threedimensionalhemipelvisestoanalysegenderspecificdifferencesinminimallyinvasiveretrogradelagscrewplacementintheposterioracetabularcolumnusingtheanteriorpelvicandmidsagittalplaneasreference
AT gonserchristophemanuel virtualmappingof260threedimensionalhemipelvisestoanalysegenderspecificdifferencesinminimallyinvasiveretrogradelagscrewplacementintheposterioracetabularcolumnusingtheanteriorpelvicandmidsagittalplaneasreference