Cargando…
Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models
To develop the logistic and the probit models to analyse electromyographic (EMG) equivalent uniform voltage- (EUV-) response for the tenderness of tennis elbow. In total, 78 hands from 39 subjects were enrolled. In this study, surface EMG (sEMG) signal is obtained by an innovative device with electr...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4561943/ https://www.ncbi.nlm.nih.gov/pubmed/26380281 http://dx.doi.org/10.1155/2015/585180 |
_version_ | 1782389092089069568 |
---|---|
author | Lee, Tsair-Fwu Lin, Wei-Chun Wang, Hung-Yu Lin, Shu-Yuan Wu, Li-Fu Guo, Shih-Sian Huang, Hsiang-Jui Ting, Hui-Min Chao, Pei-Ju |
author_facet | Lee, Tsair-Fwu Lin, Wei-Chun Wang, Hung-Yu Lin, Shu-Yuan Wu, Li-Fu Guo, Shih-Sian Huang, Hsiang-Jui Ting, Hui-Min Chao, Pei-Ju |
author_sort | Lee, Tsair-Fwu |
collection | PubMed |
description | To develop the logistic and the probit models to analyse electromyographic (EMG) equivalent uniform voltage- (EUV-) response for the tenderness of tennis elbow. In total, 78 hands from 39 subjects were enrolled. In this study, surface EMG (sEMG) signal is obtained by an innovative device with electrodes over forearm region. The analytical endpoint was defined as Visual Analog Score (VAS) 3+ tenderness of tennis elbow. The logistic and the probit diseased probability (DP) models were established for the VAS score and EMG absolute voltage-time histograms (AVTH). TV(50) is the threshold equivalent uniform voltage predicting a 50% risk of disease. Twenty-one out of 78 samples (27%) developed VAS 3+ tenderness of tennis elbow reported by the subject and confirmed by the physician. The fitted DP parameters were TV(50) = 153.0 mV (CI: 136.3–169.7 mV), γ (50) = 0.84 (CI: 0.78–0.90) and TV(50) = 155.6 mV (CI: 138.9–172.4 mV), m = 0.54 (CI: 0.49–0.59) for logistic and probit models, respectively. When the EUV ≥ 153 mV, the DP of the patient is greater than 50% and vice versa. The logistic and the probit models are valuable tools to predict the DP of VAS 3+ tenderness of tennis elbow. |
format | Online Article Text |
id | pubmed-4561943 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-45619432015-09-15 Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models Lee, Tsair-Fwu Lin, Wei-Chun Wang, Hung-Yu Lin, Shu-Yuan Wu, Li-Fu Guo, Shih-Sian Huang, Hsiang-Jui Ting, Hui-Min Chao, Pei-Ju Biomed Res Int Research Article To develop the logistic and the probit models to analyse electromyographic (EMG) equivalent uniform voltage- (EUV-) response for the tenderness of tennis elbow. In total, 78 hands from 39 subjects were enrolled. In this study, surface EMG (sEMG) signal is obtained by an innovative device with electrodes over forearm region. The analytical endpoint was defined as Visual Analog Score (VAS) 3+ tenderness of tennis elbow. The logistic and the probit diseased probability (DP) models were established for the VAS score and EMG absolute voltage-time histograms (AVTH). TV(50) is the threshold equivalent uniform voltage predicting a 50% risk of disease. Twenty-one out of 78 samples (27%) developed VAS 3+ tenderness of tennis elbow reported by the subject and confirmed by the physician. The fitted DP parameters were TV(50) = 153.0 mV (CI: 136.3–169.7 mV), γ (50) = 0.84 (CI: 0.78–0.90) and TV(50) = 155.6 mV (CI: 138.9–172.4 mV), m = 0.54 (CI: 0.49–0.59) for logistic and probit models, respectively. When the EUV ≥ 153 mV, the DP of the patient is greater than 50% and vice versa. The logistic and the probit models are valuable tools to predict the DP of VAS 3+ tenderness of tennis elbow. Hindawi Publishing Corporation 2015 2015-08-25 /pmc/articles/PMC4561943/ /pubmed/26380281 http://dx.doi.org/10.1155/2015/585180 Text en Copyright © 2015 Tsair-Fwu Lee et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Lee, Tsair-Fwu Lin, Wei-Chun Wang, Hung-Yu Lin, Shu-Yuan Wu, Li-Fu Guo, Shih-Sian Huang, Hsiang-Jui Ting, Hui-Min Chao, Pei-Ju Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models |
title | Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models |
title_full | Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models |
title_fullStr | Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models |
title_full_unstemmed | Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models |
title_short | Tennis Elbow Diagnosis Using Equivalent Uniform Voltage to Fit the Logistic and the Probit Diseased Probability Models |
title_sort | tennis elbow diagnosis using equivalent uniform voltage to fit the logistic and the probit diseased probability models |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4561943/ https://www.ncbi.nlm.nih.gov/pubmed/26380281 http://dx.doi.org/10.1155/2015/585180 |
work_keys_str_mv | AT leetsairfwu tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT linweichun tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT wanghungyu tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT linshuyuan tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT wulifu tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT guoshihsian tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT huanghsiangjui tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT tinghuimin tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels AT chaopeiju tenniselbowdiagnosisusingequivalentuniformvoltagetofitthelogisticandtheprobitdiseasedprobabilitymodels |