Cargando…
Supervised discriminant analysis for droplet micro-magnetofluidics
We apply the technique of supervised discriminant analysis (SDA) for in-flow detection in droplet-based magnetofluidics. Based on the SDA, we successfully discriminate bivariant droplets of different volumes containing different encapsulated magnetic content produced by a GMR-based lab-on-chip platf...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562118/ https://www.ncbi.nlm.nih.gov/pubmed/26379480 http://dx.doi.org/10.1007/s10404-015-1579-z |
_version_ | 1782389116857483264 |
---|---|
author | Lin, Gungun Fomin, Vladimir M. Makarov, Denys Schmidt, Oliver G. |
author_facet | Lin, Gungun Fomin, Vladimir M. Makarov, Denys Schmidt, Oliver G. |
author_sort | Lin, Gungun |
collection | PubMed |
description | We apply the technique of supervised discriminant analysis (SDA) for in-flow detection in droplet-based magnetofluidics. Based on the SDA, we successfully discriminate bivariant droplets of different volumes containing different encapsulated magnetic content produced by a GMR-based lab-on-chip platform. We demonstrate that the accuracy of discrimination is superior when the correlation of variables for data training is included to the case when the spatial distribution of variables is considered. Droplets produced with differences in ferrofluid concentration of 2.5 mg/ml and volume of 200 pl have been identified with high accuracy (98 %), indicating the significance of SDA for e.g. the discrimination in magnetic immuno-agglutination assays. Furthermore, the results open the way for the development of a unique magnetofluidic platform for future applications in multiplexed droplet-based barcoding assays and screening. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-015-1579-z) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4562118 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-45621182015-09-14 Supervised discriminant analysis for droplet micro-magnetofluidics Lin, Gungun Fomin, Vladimir M. Makarov, Denys Schmidt, Oliver G. Microfluid Nanofluidics Research Paper We apply the technique of supervised discriminant analysis (SDA) for in-flow detection in droplet-based magnetofluidics. Based on the SDA, we successfully discriminate bivariant droplets of different volumes containing different encapsulated magnetic content produced by a GMR-based lab-on-chip platform. We demonstrate that the accuracy of discrimination is superior when the correlation of variables for data training is included to the case when the spatial distribution of variables is considered. Droplets produced with differences in ferrofluid concentration of 2.5 mg/ml and volume of 200 pl have been identified with high accuracy (98 %), indicating the significance of SDA for e.g. the discrimination in magnetic immuno-agglutination assays. Furthermore, the results open the way for the development of a unique magnetofluidic platform for future applications in multiplexed droplet-based barcoding assays and screening. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-015-1579-z) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2015-04-10 2015 /pmc/articles/PMC4562118/ /pubmed/26379480 http://dx.doi.org/10.1007/s10404-015-1579-z Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Paper Lin, Gungun Fomin, Vladimir M. Makarov, Denys Schmidt, Oliver G. Supervised discriminant analysis for droplet micro-magnetofluidics |
title | Supervised discriminant analysis for droplet micro-magnetofluidics |
title_full | Supervised discriminant analysis for droplet micro-magnetofluidics |
title_fullStr | Supervised discriminant analysis for droplet micro-magnetofluidics |
title_full_unstemmed | Supervised discriminant analysis for droplet micro-magnetofluidics |
title_short | Supervised discriminant analysis for droplet micro-magnetofluidics |
title_sort | supervised discriminant analysis for droplet micro-magnetofluidics |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562118/ https://www.ncbi.nlm.nih.gov/pubmed/26379480 http://dx.doi.org/10.1007/s10404-015-1579-z |
work_keys_str_mv | AT lingungun superviseddiscriminantanalysisfordropletmicromagnetofluidics AT fominvladimirm superviseddiscriminantanalysisfordropletmicromagnetofluidics AT makarovdenys superviseddiscriminantanalysisfordropletmicromagnetofluidics AT schmidtoliverg superviseddiscriminantanalysisfordropletmicromagnetofluidics |