Supervised discriminant analysis for droplet micro-magnetofluidics

We apply the technique of supervised discriminant analysis (SDA) for in-flow detection in droplet-based magnetofluidics. Based on the SDA, we successfully discriminate bivariant droplets of different volumes containing different encapsulated magnetic content produced by a GMR-based lab-on-chip platf...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Gungun, Fomin, Vladimir M., Makarov, Denys, Schmidt, Oliver G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562118/
https://www.ncbi.nlm.nih.gov/pubmed/26379480
http://dx.doi.org/10.1007/s10404-015-1579-z
_version_ 1782389116857483264
author Lin, Gungun
Fomin, Vladimir M.
Makarov, Denys
Schmidt, Oliver G.
author_facet Lin, Gungun
Fomin, Vladimir M.
Makarov, Denys
Schmidt, Oliver G.
author_sort Lin, Gungun
collection PubMed
description We apply the technique of supervised discriminant analysis (SDA) for in-flow detection in droplet-based magnetofluidics. Based on the SDA, we successfully discriminate bivariant droplets of different volumes containing different encapsulated magnetic content produced by a GMR-based lab-on-chip platform. We demonstrate that the accuracy of discrimination is superior when the correlation of variables for data training is included to the case when the spatial distribution of variables is considered. Droplets produced with differences in ferrofluid concentration of 2.5 mg/ml and volume of 200 pl have been identified with high accuracy (98 %), indicating the significance of SDA for e.g. the discrimination in magnetic immuno-agglutination assays. Furthermore, the results open the way for the development of a unique magnetofluidic platform for future applications in multiplexed droplet-based barcoding assays and screening. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-015-1579-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4562118
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-45621182015-09-14 Supervised discriminant analysis for droplet micro-magnetofluidics Lin, Gungun Fomin, Vladimir M. Makarov, Denys Schmidt, Oliver G. Microfluid Nanofluidics Research Paper We apply the technique of supervised discriminant analysis (SDA) for in-flow detection in droplet-based magnetofluidics. Based on the SDA, we successfully discriminate bivariant droplets of different volumes containing different encapsulated magnetic content produced by a GMR-based lab-on-chip platform. We demonstrate that the accuracy of discrimination is superior when the correlation of variables for data training is included to the case when the spatial distribution of variables is considered. Droplets produced with differences in ferrofluid concentration of 2.5 mg/ml and volume of 200 pl have been identified with high accuracy (98 %), indicating the significance of SDA for e.g. the discrimination in magnetic immuno-agglutination assays. Furthermore, the results open the way for the development of a unique magnetofluidic platform for future applications in multiplexed droplet-based barcoding assays and screening. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-015-1579-z) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2015-04-10 2015 /pmc/articles/PMC4562118/ /pubmed/26379480 http://dx.doi.org/10.1007/s10404-015-1579-z Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research Paper
Lin, Gungun
Fomin, Vladimir M.
Makarov, Denys
Schmidt, Oliver G.
Supervised discriminant analysis for droplet micro-magnetofluidics
title Supervised discriminant analysis for droplet micro-magnetofluidics
title_full Supervised discriminant analysis for droplet micro-magnetofluidics
title_fullStr Supervised discriminant analysis for droplet micro-magnetofluidics
title_full_unstemmed Supervised discriminant analysis for droplet micro-magnetofluidics
title_short Supervised discriminant analysis for droplet micro-magnetofluidics
title_sort supervised discriminant analysis for droplet micro-magnetofluidics
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562118/
https://www.ncbi.nlm.nih.gov/pubmed/26379480
http://dx.doi.org/10.1007/s10404-015-1579-z
work_keys_str_mv AT lingungun superviseddiscriminantanalysisfordropletmicromagnetofluidics
AT fominvladimirm superviseddiscriminantanalysisfordropletmicromagnetofluidics
AT makarovdenys superviseddiscriminantanalysisfordropletmicromagnetofluidics
AT schmidtoliverg superviseddiscriminantanalysisfordropletmicromagnetofluidics