EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability
Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glauc...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562650/ https://www.ncbi.nlm.nih.gov/pubmed/26366105 http://dx.doi.org/10.2147/MDER.S63350 |
_version_ | 1782389190687719424 |
---|---|
author | Chan, Jessica E Netland, Peter A |
author_facet | Chan, Jessica E Netland, Peter A |
author_sort | Chan, Jessica E |
collection | PubMed |
description | Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. |
format | Online Article Text |
id | pubmed-4562650 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-45626502015-09-11 EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability Chan, Jessica E Netland, Peter A Med Devices (Auckl) Review Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. Dove Medical Press 2015-09-02 /pmc/articles/PMC4562650/ /pubmed/26366105 http://dx.doi.org/10.2147/MDER.S63350 Text en © 2015 Chan and Netland. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Review Chan, Jessica E Netland, Peter A EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title | EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_full | EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_fullStr | EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_full_unstemmed | EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_short | EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability |
title_sort | ex-press glaucoma filtration device: efficacy, safety, and predictability |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562650/ https://www.ncbi.nlm.nih.gov/pubmed/26366105 http://dx.doi.org/10.2147/MDER.S63350 |
work_keys_str_mv | AT chanjessicae expressglaucomafiltrationdeviceefficacysafetyandpredictability AT netlandpetera expressglaucomafiltrationdeviceefficacysafetyandpredictability |