Cargando…

A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies

BACKGROUND: Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterogeneity exists. Here, we have developed a general algorithm that provides a rank...

Descripción completa

Detalles Bibliográficos
Autores principales: Grafström, Jonas, Ahlzén, Hanna-Stina, Stone-Elander, Sharon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562910/
https://www.ncbi.nlm.nih.gov/pubmed/26501820
http://dx.doi.org/10.1186/s40658-015-0124-1
_version_ 1782389216550846464
author Grafström, Jonas
Ahlzén, Hanna-Stina
Stone-Elander, Sharon
author_facet Grafström, Jonas
Ahlzén, Hanna-Stina
Stone-Elander, Sharon
author_sort Grafström, Jonas
collection PubMed
description BACKGROUND: Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterogeneity exists. Here, we have developed a general algorithm that provides a ranking and a visualisation of the heterogeneity in small animal positron emission tomography (PET) images. METHODS: The code of the algorithm was written using the Matrix Laboratory software (MATLAB). Parameters known to influence the heterogeneity (distances between deviating peaks, gradients and size compensations) were incorporated into the algorithm. All data matrices were mathematically constructed in the same format with the aim of maintaining overview and control. Histograms visualising the spread and frequency of contributions to the heterogeneity were also generated. The construction of the algorithm was tested using mathematically generated matrices and by varying post-processing parameters. It was subsequently applied in comparisons of radiotracer uptake in preclinical images in human head and neck carcinoma and endothelial and ovarian carcinoma xenografts. RESULTS: Using the developed algorithm, entire tissue volumes could be assessed and gradients could be handled in an indirect manner. Similar-sized volumes could be compared without modifying the algorithm. Analyses of the distribution of different tracers gave results that were generally in accordance with single plane preclinical images, indicating that it could appropriately handle comparisons of targeting vs. non-targeting tracers and also for different target levels. Altering the reconstruction algorithm, pixel size, tumour ROI volumes and lower cut-off limits affected the calculated heterogeneity factors in expected directions but did not reverse conclusions about which tumour was more or less heterogeneous. CONCLUSIONS: The algorithm constructed is an objective and potentially user-friendly tool for one-to-one comparisons of heterogeneity in whole similar-sized tumour volumes in PET imaging.
format Online
Article
Text
id pubmed-4562910
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-45629102015-09-14 A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies Grafström, Jonas Ahlzén, Hanna-Stina Stone-Elander, Sharon EJNMMI Phys Original Research BACKGROUND: Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterogeneity exists. Here, we have developed a general algorithm that provides a ranking and a visualisation of the heterogeneity in small animal positron emission tomography (PET) images. METHODS: The code of the algorithm was written using the Matrix Laboratory software (MATLAB). Parameters known to influence the heterogeneity (distances between deviating peaks, gradients and size compensations) were incorporated into the algorithm. All data matrices were mathematically constructed in the same format with the aim of maintaining overview and control. Histograms visualising the spread and frequency of contributions to the heterogeneity were also generated. The construction of the algorithm was tested using mathematically generated matrices and by varying post-processing parameters. It was subsequently applied in comparisons of radiotracer uptake in preclinical images in human head and neck carcinoma and endothelial and ovarian carcinoma xenografts. RESULTS: Using the developed algorithm, entire tissue volumes could be assessed and gradients could be handled in an indirect manner. Similar-sized volumes could be compared without modifying the algorithm. Analyses of the distribution of different tracers gave results that were generally in accordance with single plane preclinical images, indicating that it could appropriately handle comparisons of targeting vs. non-targeting tracers and also for different target levels. Altering the reconstruction algorithm, pixel size, tumour ROI volumes and lower cut-off limits affected the calculated heterogeneity factors in expected directions but did not reverse conclusions about which tumour was more or less heterogeneous. CONCLUSIONS: The algorithm constructed is an objective and potentially user-friendly tool for one-to-one comparisons of heterogeneity in whole similar-sized tumour volumes in PET imaging. Springer International Publishing 2015-09-08 /pmc/articles/PMC4562910/ /pubmed/26501820 http://dx.doi.org/10.1186/s40658-015-0124-1 Text en © Grafström et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Grafström, Jonas
Ahlzén, Hanna-Stina
Stone-Elander, Sharon
A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
title A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
title_full A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
title_fullStr A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
title_full_unstemmed A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
title_short A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
title_sort method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4562910/
https://www.ncbi.nlm.nih.gov/pubmed/26501820
http://dx.doi.org/10.1186/s40658-015-0124-1
work_keys_str_mv AT grafstromjonas amethodforcomparingintratumouralradioactivityuptakeheterogeneityinpreclinicalpositronemissiontomographystudies
AT ahlzenhannastina amethodforcomparingintratumouralradioactivityuptakeheterogeneityinpreclinicalpositronemissiontomographystudies
AT stoneelandersharon amethodforcomparingintratumouralradioactivityuptakeheterogeneityinpreclinicalpositronemissiontomographystudies
AT grafstromjonas methodforcomparingintratumouralradioactivityuptakeheterogeneityinpreclinicalpositronemissiontomographystudies
AT ahlzenhannastina methodforcomparingintratumouralradioactivityuptakeheterogeneityinpreclinicalpositronemissiontomographystudies
AT stoneelandersharon methodforcomparingintratumouralradioactivityuptakeheterogeneityinpreclinicalpositronemissiontomographystudies