Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564227/ https://www.ncbi.nlm.nih.gov/pubmed/26352144 http://dx.doi.org/10.1371/journal.pone.0137165 |
_version_ | 1782389400714346496 |
---|---|
author | Kakinuma, Ryutaro Moriyama, Noriyuki Muramatsu, Yukio Gomi, Shiho Suzuki, Masahiro Nagasawa, Hirobumi Kusumoto, Masahiko Aso, Tomohiko Muramatsu, Yoshihisa Tsuchida, Takaaki Tsuta, Koji Maeshima, Akiko Miyagi Tochigi, Naobumi Watanabe, Shun-ichi Sugihara, Naoki Tsukagoshi, Shinsuke Saito, Yasuo Kazama, Masahiro Ashizawa, Kazuto Awai, Kazuo Honda, Osamu Ishikawa, Hiroyuki Koizumi, Naoya Komoto, Daisuke Moriya, Hiroshi Oda, Seitaro Oshiro, Yasuji Yanagawa, Masahiro Tomiyama, Noriyuki Asamura, Hisao |
author_facet | Kakinuma, Ryutaro Moriyama, Noriyuki Muramatsu, Yukio Gomi, Shiho Suzuki, Masahiro Nagasawa, Hirobumi Kusumoto, Masahiko Aso, Tomohiko Muramatsu, Yoshihisa Tsuchida, Takaaki Tsuta, Koji Maeshima, Akiko Miyagi Tochigi, Naobumi Watanabe, Shun-ichi Sugihara, Naoki Tsukagoshi, Shinsuke Saito, Yasuo Kazama, Masahiro Ashizawa, Kazuto Awai, Kazuo Honda, Osamu Ishikawa, Hiroyuki Koizumi, Naoya Komoto, Daisuke Moriya, Hiroshi Oda, Seitaro Oshiro, Yasuji Yanagawa, Masahiro Tomiyama, Noriyuki Asamura, Hisao |
author_sort | Kakinuma, Ryutaro |
collection | PubMed |
description | PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. RESULTS: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. CONCLUSION: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. |
format | Online Article Text |
id | pubmed-4564227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-45642272015-09-17 Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner Kakinuma, Ryutaro Moriyama, Noriyuki Muramatsu, Yukio Gomi, Shiho Suzuki, Masahiro Nagasawa, Hirobumi Kusumoto, Masahiko Aso, Tomohiko Muramatsu, Yoshihisa Tsuchida, Takaaki Tsuta, Koji Maeshima, Akiko Miyagi Tochigi, Naobumi Watanabe, Shun-ichi Sugihara, Naoki Tsukagoshi, Shinsuke Saito, Yasuo Kazama, Masahiro Ashizawa, Kazuto Awai, Kazuo Honda, Osamu Ishikawa, Hiroyuki Koizumi, Naoya Komoto, Daisuke Moriya, Hiroshi Oda, Seitaro Oshiro, Yasuji Yanagawa, Masahiro Tomiyama, Noriyuki Asamura, Hisao PLoS One Research Article PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. RESULTS: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. CONCLUSION: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. Public Library of Science 2015-09-09 /pmc/articles/PMC4564227/ /pubmed/26352144 http://dx.doi.org/10.1371/journal.pone.0137165 Text en © 2015 Kakinuma et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Kakinuma, Ryutaro Moriyama, Noriyuki Muramatsu, Yukio Gomi, Shiho Suzuki, Masahiro Nagasawa, Hirobumi Kusumoto, Masahiko Aso, Tomohiko Muramatsu, Yoshihisa Tsuchida, Takaaki Tsuta, Koji Maeshima, Akiko Miyagi Tochigi, Naobumi Watanabe, Shun-ichi Sugihara, Naoki Tsukagoshi, Shinsuke Saito, Yasuo Kazama, Masahiro Ashizawa, Kazuto Awai, Kazuo Honda, Osamu Ishikawa, Hiroyuki Koizumi, Naoya Komoto, Daisuke Moriya, Hiroshi Oda, Seitaro Oshiro, Yasuji Yanagawa, Masahiro Tomiyama, Noriyuki Asamura, Hisao Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner |
title | Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner |
title_full | Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner |
title_fullStr | Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner |
title_full_unstemmed | Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner |
title_short | Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner |
title_sort | ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564227/ https://www.ncbi.nlm.nih.gov/pubmed/26352144 http://dx.doi.org/10.1371/journal.pone.0137165 |
work_keys_str_mv | AT kakinumaryutaro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT moriyamanoriyuki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT muramatsuyukio ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT gomishiho ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT suzukimasahiro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT nagasawahirobumi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT kusumotomasahiko ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT asotomohiko ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT muramatsuyoshihisa ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT tsuchidatakaaki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT tsutakoji ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT maeshimaakikomiyagi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT tochiginaobumi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT watanabeshunichi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT sugiharanaoki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT tsukagoshishinsuke ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT saitoyasuo ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT kazamamasahiro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT ashizawakazuto ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT awaikazuo ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT hondaosamu ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT ishikawahiroyuki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT koizuminaoya ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT komotodaisuke ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT moriyahiroshi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT odaseitaro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT oshiroyasuji ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT yanagawamasahiro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT tomiyamanoriyuki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner AT asamurahisao ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner |