Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT...

Descripción completa

Detalles Bibliográficos
Autores principales: Kakinuma, Ryutaro, Moriyama, Noriyuki, Muramatsu, Yukio, Gomi, Shiho, Suzuki, Masahiro, Nagasawa, Hirobumi, Kusumoto, Masahiko, Aso, Tomohiko, Muramatsu, Yoshihisa, Tsuchida, Takaaki, Tsuta, Koji, Maeshima, Akiko Miyagi, Tochigi, Naobumi, Watanabe, Shun-ichi, Sugihara, Naoki, Tsukagoshi, Shinsuke, Saito, Yasuo, Kazama, Masahiro, Ashizawa, Kazuto, Awai, Kazuo, Honda, Osamu, Ishikawa, Hiroyuki, Koizumi, Naoya, Komoto, Daisuke, Moriya, Hiroshi, Oda, Seitaro, Oshiro, Yasuji, Yanagawa, Masahiro, Tomiyama, Noriyuki, Asamura, Hisao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564227/
https://www.ncbi.nlm.nih.gov/pubmed/26352144
http://dx.doi.org/10.1371/journal.pone.0137165
_version_ 1782389400714346496
author Kakinuma, Ryutaro
Moriyama, Noriyuki
Muramatsu, Yukio
Gomi, Shiho
Suzuki, Masahiro
Nagasawa, Hirobumi
Kusumoto, Masahiko
Aso, Tomohiko
Muramatsu, Yoshihisa
Tsuchida, Takaaki
Tsuta, Koji
Maeshima, Akiko Miyagi
Tochigi, Naobumi
Watanabe, Shun-ichi
Sugihara, Naoki
Tsukagoshi, Shinsuke
Saito, Yasuo
Kazama, Masahiro
Ashizawa, Kazuto
Awai, Kazuo
Honda, Osamu
Ishikawa, Hiroyuki
Koizumi, Naoya
Komoto, Daisuke
Moriya, Hiroshi
Oda, Seitaro
Oshiro, Yasuji
Yanagawa, Masahiro
Tomiyama, Noriyuki
Asamura, Hisao
author_facet Kakinuma, Ryutaro
Moriyama, Noriyuki
Muramatsu, Yukio
Gomi, Shiho
Suzuki, Masahiro
Nagasawa, Hirobumi
Kusumoto, Masahiko
Aso, Tomohiko
Muramatsu, Yoshihisa
Tsuchida, Takaaki
Tsuta, Koji
Maeshima, Akiko Miyagi
Tochigi, Naobumi
Watanabe, Shun-ichi
Sugihara, Naoki
Tsukagoshi, Shinsuke
Saito, Yasuo
Kazama, Masahiro
Ashizawa, Kazuto
Awai, Kazuo
Honda, Osamu
Ishikawa, Hiroyuki
Koizumi, Naoya
Komoto, Daisuke
Moriya, Hiroshi
Oda, Seitaro
Oshiro, Yasuji
Yanagawa, Masahiro
Tomiyama, Noriyuki
Asamura, Hisao
author_sort Kakinuma, Ryutaro
collection PubMed
description PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. RESULTS: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. CONCLUSION: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.
format Online
Article
Text
id pubmed-4564227
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45642272015-09-17 Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner Kakinuma, Ryutaro Moriyama, Noriyuki Muramatsu, Yukio Gomi, Shiho Suzuki, Masahiro Nagasawa, Hirobumi Kusumoto, Masahiko Aso, Tomohiko Muramatsu, Yoshihisa Tsuchida, Takaaki Tsuta, Koji Maeshima, Akiko Miyagi Tochigi, Naobumi Watanabe, Shun-ichi Sugihara, Naoki Tsukagoshi, Shinsuke Saito, Yasuo Kazama, Masahiro Ashizawa, Kazuto Awai, Kazuo Honda, Osamu Ishikawa, Hiroyuki Koizumi, Naoya Komoto, Daisuke Moriya, Hiroshi Oda, Seitaro Oshiro, Yasuji Yanagawa, Masahiro Tomiyama, Noriyuki Asamura, Hisao PLoS One Research Article PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. RESULTS: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. CONCLUSION: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. Public Library of Science 2015-09-09 /pmc/articles/PMC4564227/ /pubmed/26352144 http://dx.doi.org/10.1371/journal.pone.0137165 Text en © 2015 Kakinuma et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Kakinuma, Ryutaro
Moriyama, Noriyuki
Muramatsu, Yukio
Gomi, Shiho
Suzuki, Masahiro
Nagasawa, Hirobumi
Kusumoto, Masahiko
Aso, Tomohiko
Muramatsu, Yoshihisa
Tsuchida, Takaaki
Tsuta, Koji
Maeshima, Akiko Miyagi
Tochigi, Naobumi
Watanabe, Shun-ichi
Sugihara, Naoki
Tsukagoshi, Shinsuke
Saito, Yasuo
Kazama, Masahiro
Ashizawa, Kazuto
Awai, Kazuo
Honda, Osamu
Ishikawa, Hiroyuki
Koizumi, Naoya
Komoto, Daisuke
Moriya, Hiroshi
Oda, Seitaro
Oshiro, Yasuji
Yanagawa, Masahiro
Tomiyama, Noriyuki
Asamura, Hisao
Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
title Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
title_full Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
title_fullStr Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
title_full_unstemmed Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
title_short Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner
title_sort ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564227/
https://www.ncbi.nlm.nih.gov/pubmed/26352144
http://dx.doi.org/10.1371/journal.pone.0137165
work_keys_str_mv AT kakinumaryutaro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT moriyamanoriyuki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT muramatsuyukio ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT gomishiho ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT suzukimasahiro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT nagasawahirobumi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT kusumotomasahiko ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT asotomohiko ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT muramatsuyoshihisa ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT tsuchidatakaaki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT tsutakoji ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT maeshimaakikomiyagi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT tochiginaobumi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT watanabeshunichi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT sugiharanaoki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT tsukagoshishinsuke ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT saitoyasuo ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT kazamamasahiro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT ashizawakazuto ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT awaikazuo ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT hondaosamu ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT ishikawahiroyuki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT koizuminaoya ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT komotodaisuke ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT moriyahiroshi ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT odaseitaro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT oshiroyasuji ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT yanagawamasahiro ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT tomiyamanoriyuki ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner
AT asamurahisao ultrahighresolutioncomputedtomographyofthelungimagequalityofaprototypescanner