Cargando…
Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique
This study was to evaluate the proposed consecutive multishot echo planar imaging (cmsEPI) combined with a parallel imaging technique in terms of signal-to-noise ratio (SNR) and acceleration for a functional imaging study. We developed cmsEPI sequence using both consecutively acquired multishot EPI...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564598/ https://www.ncbi.nlm.nih.gov/pubmed/26413518 http://dx.doi.org/10.1155/2015/394213 |
_version_ | 1782389460134002688 |
---|---|
author | Kang, Daehun Sung, Yul-Wan Kang, Chang-Ki |
author_facet | Kang, Daehun Sung, Yul-Wan Kang, Chang-Ki |
author_sort | Kang, Daehun |
collection | PubMed |
description | This study was to evaluate the proposed consecutive multishot echo planar imaging (cmsEPI) combined with a parallel imaging technique in terms of signal-to-noise ratio (SNR) and acceleration for a functional imaging study. We developed cmsEPI sequence using both consecutively acquired multishot EPI segments and variable flip angles to minimize the delay between segments and to maximize the SNR, respectively. We also combined cmsEPI with the generalized autocalibrating partially parallel acquisitions (GRAPPA) method. Temporal SNRs were measured at different acceleration factors and number of segments for functional sensitivity evaluation. We also examined the geometric distortions, which inherently occurred in EPI sequence. The practical acceleration factors, R = 2 or R = 3, of the proposed technique improved the temporal SNR by maximally 18% in phantom test and by averagely 8.2% in in vivo experiment, compared to cmsEPI without parallel imaging. The data collection time was decreased in inverse proportion to the acceleration factor as well. The improved temporal SNR resulted in better statistical power when evaluated on the functional response of the brain. In this study, we demonstrated that the combination of cmsEPI with the parallel imaging technique could provide the improved functional sensitivity for functional imaging study, compensating for the lower SNR by cmsEPI. |
format | Online Article Text |
id | pubmed-4564598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-45645982015-09-27 Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique Kang, Daehun Sung, Yul-Wan Kang, Chang-Ki Biomed Res Int Research Article This study was to evaluate the proposed consecutive multishot echo planar imaging (cmsEPI) combined with a parallel imaging technique in terms of signal-to-noise ratio (SNR) and acceleration for a functional imaging study. We developed cmsEPI sequence using both consecutively acquired multishot EPI segments and variable flip angles to minimize the delay between segments and to maximize the SNR, respectively. We also combined cmsEPI with the generalized autocalibrating partially parallel acquisitions (GRAPPA) method. Temporal SNRs were measured at different acceleration factors and number of segments for functional sensitivity evaluation. We also examined the geometric distortions, which inherently occurred in EPI sequence. The practical acceleration factors, R = 2 or R = 3, of the proposed technique improved the temporal SNR by maximally 18% in phantom test and by averagely 8.2% in in vivo experiment, compared to cmsEPI without parallel imaging. The data collection time was decreased in inverse proportion to the acceleration factor as well. The improved temporal SNR resulted in better statistical power when evaluated on the functional response of the brain. In this study, we demonstrated that the combination of cmsEPI with the parallel imaging technique could provide the improved functional sensitivity for functional imaging study, compensating for the lower SNR by cmsEPI. Hindawi Publishing Corporation 2015 2015-08-27 /pmc/articles/PMC4564598/ /pubmed/26413518 http://dx.doi.org/10.1155/2015/394213 Text en Copyright © 2015 Daehun Kang et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Kang, Daehun Sung, Yul-Wan Kang, Chang-Ki Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique |
title | Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique |
title_full | Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique |
title_fullStr | Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique |
title_full_unstemmed | Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique |
title_short | Fast Imaging Technique for fMRI: Consecutive Multishot Echo Planar Imaging Accelerated with GRAPPA Technique |
title_sort | fast imaging technique for fmri: consecutive multishot echo planar imaging accelerated with grappa technique |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564598/ https://www.ncbi.nlm.nih.gov/pubmed/26413518 http://dx.doi.org/10.1155/2015/394213 |
work_keys_str_mv | AT kangdaehun fastimagingtechniqueforfmriconsecutivemultishotechoplanarimagingacceleratedwithgrappatechnique AT sungyulwan fastimagingtechniqueforfmriconsecutivemultishotechoplanarimagingacceleratedwithgrappatechnique AT kangchangki fastimagingtechniqueforfmriconsecutivemultishotechoplanarimagingacceleratedwithgrappatechnique |