Cargando…

The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study

The collimator in single-photon emission computed tomography (SPECT) is a critical component of the imaging system and plays an impressive role in the imaging quality. In this study, the effect of the collimator material on the radioisotopic image and its functional parameters was studied. The simul...

Descripción completa

Detalles Bibliográficos
Autores principales: Azarm, Ahmadreza, Islamian, Jalil Pirayesh, Mahmoudian, Babak, Gharepapagh, Esmaeil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564917/
https://www.ncbi.nlm.nih.gov/pubmed/26420985
http://dx.doi.org/10.4103/1450-1147.163242
_version_ 1782389519984623616
author Azarm, Ahmadreza
Islamian, Jalil Pirayesh
Mahmoudian, Babak
Gharepapagh, Esmaeil
author_facet Azarm, Ahmadreza
Islamian, Jalil Pirayesh
Mahmoudian, Babak
Gharepapagh, Esmaeil
author_sort Azarm, Ahmadreza
collection PubMed
description The collimator in single-photon emission computed tomography (SPECT) is a critical component of the imaging system and plays an impressive role in the imaging quality. In this study, the effect of the collimator material on the radioisotopic image and its functional parameters was studied. The simulating medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate a Siemens E.CAM SPECT (Siemens Medical Solutions, Erlangen, Germany) system equipped with a low-energy high-resolution (LEHR) collimator. The simulation and experimental data from the SPECT imaging modality using (99m)Tc were obtained on a point source and Jaszczak phantom. Seventeen high atomic number materials were considered as LEHR collimator materials. In order to determine the effect of the collimator material on the image and functional parameters, the energy resolution, spatial resolution, contrast, and collimator characteristics parameters such as septal penetration and scatter-to-primary ratio were investigated. Energy spectra profiles, full width at half maximums (FWHMs) (mm) of the point spread function (PSF) curves, system sensitivity, and contrast of cold spheres of the Jaszczak phantom for the simulated and experiment systems have acceptability superimposed. The results of FWHM and energy resolution for the 17 collimators showed that the collimator made of 98% lead and 2% antimony could provide the best FWHM and energy resolution, 7.68 mm and 9.87%, respectively. The LEHR collimator with 98% lead and 2% antimony offers the best resolution and contrast when compared to other high atomic number metals and alloys.
format Online
Article
Text
id pubmed-4564917
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-45649172015-09-29 The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study Azarm, Ahmadreza Islamian, Jalil Pirayesh Mahmoudian, Babak Gharepapagh, Esmaeil World J Nucl Med Original Article The collimator in single-photon emission computed tomography (SPECT) is a critical component of the imaging system and plays an impressive role in the imaging quality. In this study, the effect of the collimator material on the radioisotopic image and its functional parameters was studied. The simulating medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate a Siemens E.CAM SPECT (Siemens Medical Solutions, Erlangen, Germany) system equipped with a low-energy high-resolution (LEHR) collimator. The simulation and experimental data from the SPECT imaging modality using (99m)Tc were obtained on a point source and Jaszczak phantom. Seventeen high atomic number materials were considered as LEHR collimator materials. In order to determine the effect of the collimator material on the image and functional parameters, the energy resolution, spatial resolution, contrast, and collimator characteristics parameters such as septal penetration and scatter-to-primary ratio were investigated. Energy spectra profiles, full width at half maximums (FWHMs) (mm) of the point spread function (PSF) curves, system sensitivity, and contrast of cold spheres of the Jaszczak phantom for the simulated and experiment systems have acceptability superimposed. The results of FWHM and energy resolution for the 17 collimators showed that the collimator made of 98% lead and 2% antimony could provide the best FWHM and energy resolution, 7.68 mm and 9.87%, respectively. The LEHR collimator with 98% lead and 2% antimony offers the best resolution and contrast when compared to other high atomic number metals and alloys. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4564917/ /pubmed/26420985 http://dx.doi.org/10.4103/1450-1147.163242 Text en Copyright: © World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Azarm, Ahmadreza
Islamian, Jalil Pirayesh
Mahmoudian, Babak
Gharepapagh, Esmaeil
The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
title The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
title_full The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
title_fullStr The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
title_full_unstemmed The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
title_short The Effect of Parallel-hole Collimator Material on Image and Functional Parameters in SPECT Imaging: A SIMIND Monte Carlo Study
title_sort effect of parallel-hole collimator material on image and functional parameters in spect imaging: a simind monte carlo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4564917/
https://www.ncbi.nlm.nih.gov/pubmed/26420985
http://dx.doi.org/10.4103/1450-1147.163242
work_keys_str_mv AT azarmahmadreza theeffectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT islamianjalilpirayesh theeffectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT mahmoudianbabak theeffectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT gharepapaghesmaeil theeffectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT azarmahmadreza effectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT islamianjalilpirayesh effectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT mahmoudianbabak effectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy
AT gharepapaghesmaeil effectofparallelholecollimatormaterialonimageandfunctionalparametersinspectimagingasimindmontecarlostudy