Cargando…
Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway
INTRODUCTION: Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4567335/ https://www.ncbi.nlm.nih.gov/pubmed/26360255 http://dx.doi.org/10.1371/journal.pone.0137825 |
_version_ | 1782389810792497152 |
---|---|
author | Grams, Samantha Torres Kimoto, Karen Yumi Mota Azevedo, Elen Moda de Oliveira Lança, Marina de Albuquerque, André Luis Pereira de Brito, Christina May Moran Yamaguti, Wellington Pereira |
author_facet | Grams, Samantha Torres Kimoto, Karen Yumi Mota Azevedo, Elen Moda de Oliveira Lança, Marina de Albuquerque, André Luis Pereira de Brito, Christina May Moran Yamaguti, Wellington Pereira |
author_sort | Grams, Samantha Torres |
collection | PubMed |
description | INTRODUCTION: Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. OBJECTIVES: This study aimed to compare the MIP values assessed by standard method (MIP(sta)) and by unidirectional expiratory valve method (MIP(uni)) in subjects with spontaneous breathing without artificial airway. MIP(uni) reproducibility was also evaluated. METHODS: This was a crossover design study, and 31 subjects performed MIP(sta) and MIP(uni) in a random order. MIP(sta) measured MIP maintaining negative pressure for at least one second after forceful expiration. MIP(uni) evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC([2,1])) was used to determine intraobserver and interobserver reproducibility. RESULTS: The mean values for MIP(uni) were 14.3% higher (-117.3 ± 24.8 cmH(2)O) than the mean values for MIP(sta) (-102.5 ± 23.9 cmH(2)O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC([2,1]) = 0.91), and high correlation for Test 2 (ICC([2,1]) = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC([2,1]) = 0.86) and evaluator B (ICC([2,1]) = 0.77). CONCLUSIONS: MIP(uni) presented higher values when compared with MIP(sta) and proved to be reproducible in subjects with spontaneous breathing without artificial airway. |
format | Online Article Text |
id | pubmed-4567335 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-45673352015-09-18 Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway Grams, Samantha Torres Kimoto, Karen Yumi Mota Azevedo, Elen Moda de Oliveira Lança, Marina de Albuquerque, André Luis Pereira de Brito, Christina May Moran Yamaguti, Wellington Pereira PLoS One Research Article INTRODUCTION: Maximal Inspiratory Pressure (MIP) is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway. OBJECTIVES: This study aimed to compare the MIP values assessed by standard method (MIP(sta)) and by unidirectional expiratory valve method (MIP(uni)) in subjects with spontaneous breathing without artificial airway. MIP(uni) reproducibility was also evaluated. METHODS: This was a crossover design study, and 31 subjects performed MIP(sta) and MIP(uni) in a random order. MIP(sta) measured MIP maintaining negative pressure for at least one second after forceful expiration. MIP(uni) evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B) at two moments (Tests 1 and 2) to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC([2,1])) was used to determine intraobserver and interobserver reproducibility. RESULTS: The mean values for MIP(uni) were 14.3% higher (-117.3 ± 24.8 cmH(2)O) than the mean values for MIP(sta) (-102.5 ± 23.9 cmH(2)O) (p<0.001). Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC([2,1]) = 0.91), and high correlation for Test 2 (ICC([2,1]) = 0.88). The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC([2,1]) = 0.86) and evaluator B (ICC([2,1]) = 0.77). CONCLUSIONS: MIP(uni) presented higher values when compared with MIP(sta) and proved to be reproducible in subjects with spontaneous breathing without artificial airway. Public Library of Science 2015-09-11 /pmc/articles/PMC4567335/ /pubmed/26360255 http://dx.doi.org/10.1371/journal.pone.0137825 Text en © 2015 Grams et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Grams, Samantha Torres Kimoto, Karen Yumi Mota Azevedo, Elen Moda de Oliveira Lança, Marina de Albuquerque, André Luis Pereira de Brito, Christina May Moran Yamaguti, Wellington Pereira Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway |
title | Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway |
title_full | Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway |
title_fullStr | Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway |
title_full_unstemmed | Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway |
title_short | Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway |
title_sort | unidirectional expiratory valve method to assess maximal inspiratory pressure in individuals without artificial airway |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4567335/ https://www.ncbi.nlm.nih.gov/pubmed/26360255 http://dx.doi.org/10.1371/journal.pone.0137825 |
work_keys_str_mv | AT gramssamanthatorres unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway AT kimotokarenyumimota unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway AT azevedoelenmodadeoliveira unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway AT lancamarina unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway AT dealbuquerqueandreluispereira unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway AT debritochristinamaymoran unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway AT yamagutiwellingtonpereira unidirectionalexpiratoryvalvemethodtoassessmaximalinspiratorypressureinindividualswithoutartificialairway |