Cargando…

A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip

Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tin...

Descripción completa

Detalles Bibliográficos
Autores principales: Balakrishnan, S. R., Hashim, U., Gopinath, Subash C. B., Poopalan, P., Ramayya, H. R., Iqbal Omar, M., Haarindraprasad, R., Veeradasan, P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4569379/
https://www.ncbi.nlm.nih.gov/pubmed/26368287
http://dx.doi.org/10.1371/journal.pone.0137891
_version_ 1782390035182518272
author Balakrishnan, S. R.
Hashim, U.
Gopinath, Subash C. B.
Poopalan, P.
Ramayya, H. R.
Iqbal Omar, M.
Haarindraprasad, R.
Veeradasan, P.
author_facet Balakrishnan, S. R.
Hashim, U.
Gopinath, Subash C. B.
Poopalan, P.
Ramayya, H. R.
Iqbal Omar, M.
Haarindraprasad, R.
Veeradasan, P.
author_sort Balakrishnan, S. R.
collection PubMed
description Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 μA mIU(-1) ml(-2) cm(-2) was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant K(d) of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was B(max) = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets.
format Online
Article
Text
id pubmed-4569379
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-45693792015-09-18 A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip Balakrishnan, S. R. Hashim, U. Gopinath, Subash C. B. Poopalan, P. Ramayya, H. R. Iqbal Omar, M. Haarindraprasad, R. Veeradasan, P. PLoS One Research Article Human chorionic gonadotropin (hCG), a glycoprotein hormone secreted from the placenta, is a key molecule that indicates pregnancy. Here, we have designed a cost-effective, label-free, in situ point-of-care (POC) immunosensor to estimate hCG using a cuneated 25 nm polysilicon nanogap electrode. A tiny chip with the dimensions of 20.5 × 12.5 mm was fabricated using conventional lithography and size expansion techniques. Furthermore, the sensing surface was functionalized by (3-aminopropyl)triethoxysilane and quantitatively measured the variations in hCG levels from clinically obtained human urine samples. The dielectric properties of the present sensor are shown with a capacitance above 40 nF for samples from pregnant women; it was lower with samples from non-pregnant women. Furthermore, it has been proven that our sensor has a wide linear range of detection, as a sensitivity of 835.88 μA mIU(-1) ml(-2) cm(-2) was attained, and the detection limit was 0.28 mIU/ml (27.78 pg/ml). The dissociation constant K(d) of the specific antigen binding to the anti-hCG was calculated as 2.23 ± 0.66 mIU, and the maximum number of binding sites per antigen was B(max) = 22.54 ± 1.46 mIU. The sensing system shown here, with a narrow nanogap, is suitable for high-throughput POC diagnosis, and a single injection can obtain triplicate data or parallel analyses of different targets. Public Library of Science 2015-09-14 /pmc/articles/PMC4569379/ /pubmed/26368287 http://dx.doi.org/10.1371/journal.pone.0137891 Text en © 2015 Balakrishnan et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Balakrishnan, S. R.
Hashim, U.
Gopinath, Subash C. B.
Poopalan, P.
Ramayya, H. R.
Iqbal Omar, M.
Haarindraprasad, R.
Veeradasan, P.
A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip
title A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip
title_full A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip
title_fullStr A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip
title_full_unstemmed A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip
title_short A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip
title_sort point-of-care immunosensor for human chorionic gonadotropin in clinical urine samples using a cuneated polysilicon nanogap lab-on-chip
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4569379/
https://www.ncbi.nlm.nih.gov/pubmed/26368287
http://dx.doi.org/10.1371/journal.pone.0137891
work_keys_str_mv AT balakrishnansr apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT hashimu apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT gopinathsubashcb apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT poopalanp apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT ramayyahr apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT iqbalomarm apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT haarindraprasadr apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT veeradasanp apointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT balakrishnansr pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT hashimu pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT gopinathsubashcb pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT poopalanp pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT ramayyahr pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT iqbalomarm pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT haarindraprasadr pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip
AT veeradasanp pointofcareimmunosensorforhumanchorionicgonadotropininclinicalurinesamplesusingacuneatedpolysiliconnanogaplabonchip