Dynamic control of pH in esophagus diseases treatment

During complete medical checkup of proximal gastrointestinal tract, the esophagus pH measurement is an adventive procedure that requires probes usage, which is introduced through the endoscope biopsy channel. Such procedure cannot be used for everyday dynamic treatment control because of its invasiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Reshetilov, Y., Dmytryeva, S., Tsapryka, O., Huz, N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4569936/
https://www.ncbi.nlm.nih.gov/pubmed/26425536
_version_ 1782390132778729472
author Reshetilov, Y.
Dmytryeva, S.
Tsapryka, O.
Huz, N.
author_facet Reshetilov, Y.
Dmytryeva, S.
Tsapryka, O.
Huz, N.
author_sort Reshetilov, Y.
collection PubMed
description During complete medical checkup of proximal gastrointestinal tract, the esophagus pH measurement is an adventive procedure that requires probes usage, which is introduced through the endoscope biopsy channel. Such procedure cannot be used for everyday dynamic treatment control because of its invasiveness. The main aim of this article is to develop an effective everyday quality control of esophagus diseases non-traumatic antisecretory treatment. We solve the problem by measuring the air-ionic esophagus internal environment characteristics with the help of the air exhaled by the patient analysis. Initial examination is provided during endoscopic research in the period of patient's planned checkup. Esophagus air tests are get through biopsy channel and analyzed by computer air-ionic complex. The range of air-ionic concentration in the esophagus air content is 0.060-0.040 (60-40%) in electrical voltage 0.020-0.050 V, which corresponds to pH 5.0-7.0. The esophagus air content indexes, received from primary samples are used as gauging for air-ionic characteristics of air exhausted by patient. Hereafter, during the therapy course we study only air samples exhausted by the patient on a daily basis. Air-ionic esophageal pH — measurement is used during checkup and treatment of 42 patients with gastroesophageal reflux disease diagnose. Parallel usage of invasive esophageal pH determination method demonstrated complete results match. Thus, the proposed method is an advanced non-invasive diagnostic method, which allows to measure intra-esophagus pH indexes and provides probable assessment of antisecretory drugs treatment efficacy with an ability of therapeutic course operative correction.
format Online
Article
Text
id pubmed-4569936
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-45699362015-09-30 Dynamic control of pH in esophagus diseases treatment Reshetilov, Y. Dmytryeva, S. Tsapryka, O. Huz, N. Endosc Ultrasound EURO EUS Meeting During complete medical checkup of proximal gastrointestinal tract, the esophagus pH measurement is an adventive procedure that requires probes usage, which is introduced through the endoscope biopsy channel. Such procedure cannot be used for everyday dynamic treatment control because of its invasiveness. The main aim of this article is to develop an effective everyday quality control of esophagus diseases non-traumatic antisecretory treatment. We solve the problem by measuring the air-ionic esophagus internal environment characteristics with the help of the air exhaled by the patient analysis. Initial examination is provided during endoscopic research in the period of patient's planned checkup. Esophagus air tests are get through biopsy channel and analyzed by computer air-ionic complex. The range of air-ionic concentration in the esophagus air content is 0.060-0.040 (60-40%) in electrical voltage 0.020-0.050 V, which corresponds to pH 5.0-7.0. The esophagus air content indexes, received from primary samples are used as gauging for air-ionic characteristics of air exhausted by patient. Hereafter, during the therapy course we study only air samples exhausted by the patient on a daily basis. Air-ionic esophageal pH — measurement is used during checkup and treatment of 42 patients with gastroesophageal reflux disease diagnose. Parallel usage of invasive esophageal pH determination method demonstrated complete results match. Thus, the proposed method is an advanced non-invasive diagnostic method, which allows to measure intra-esophagus pH indexes and provides probable assessment of antisecretory drugs treatment efficacy with an ability of therapeutic course operative correction. Medknow Publications & Media Pvt Ltd 2014-04 /pmc/articles/PMC4569936/ /pubmed/26425536 Text en Copyright: © Endoscopic Ultrasound http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle EURO EUS Meeting
Reshetilov, Y.
Dmytryeva, S.
Tsapryka, O.
Huz, N.
Dynamic control of pH in esophagus diseases treatment
title Dynamic control of pH in esophagus diseases treatment
title_full Dynamic control of pH in esophagus diseases treatment
title_fullStr Dynamic control of pH in esophagus diseases treatment
title_full_unstemmed Dynamic control of pH in esophagus diseases treatment
title_short Dynamic control of pH in esophagus diseases treatment
title_sort dynamic control of ph in esophagus diseases treatment
topic EURO EUS Meeting
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4569936/
https://www.ncbi.nlm.nih.gov/pubmed/26425536
work_keys_str_mv AT reshetilovy dynamiccontrolofphinesophagusdiseasestreatment
AT dmytryevas dynamiccontrolofphinesophagusdiseasestreatment
AT tsaprykao dynamiccontrolofphinesophagusdiseasestreatment
AT huzn dynamiccontrolofphinesophagusdiseasestreatment