Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations
Magneto-Inertial Measurement Unit sensors (MIMU) display high potential for the quantitative evaluation of upper limb kinematics, as they allow monitoring ambulatory measurements. The sensor-to-segment calibration step, consisting of establishing the relation between MIMU sensors and human segments,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570347/ https://www.ncbi.nlm.nih.gov/pubmed/26263993 http://dx.doi.org/10.3390/s150818813 |
_version_ | 1782390188891176960 |
---|---|
author | Bouvier, Brice Duprey, Sonia Claudon, Laurent Dumas, Raphaël Savescu, Adriana |
author_facet | Bouvier, Brice Duprey, Sonia Claudon, Laurent Dumas, Raphaël Savescu, Adriana |
author_sort | Bouvier, Brice |
collection | PubMed |
description | Magneto-Inertial Measurement Unit sensors (MIMU) display high potential for the quantitative evaluation of upper limb kinematics, as they allow monitoring ambulatory measurements. The sensor-to-segment calibration step, consisting of establishing the relation between MIMU sensors and human segments, plays an important role in the global accuracy of joint angles. The aim of this study was to compare sensor-to-segment calibrations for the MIMU-based estimation of wrist, elbow, and shoulder joint angles, by examining trueness (“close to the reference”) and precision (reproducibility) validity criteria. Ten subjects performed five sessions with three different operators. Three classes of calibrations were studied: segment axes equal to technical MIMU axes (TECH), segment axes generated during a static pose (STATIC), and those generated during functional movements (FUNCT). The calibrations were compared during the maximal uniaxial movements of each joint, plus an extra multi-joint movement. Generally, joint angles presented good trueness and very good precision in the range 5°–10°. Only small discrepancy between calibrations was highlighted, with the exception of a few cases. The very good overall accuracy (trueness and precision) of MIMU-based joint angle data seems to be more dependent on the level of rigor of the experimental procedure (operator training) than on the choice of calibration itself. |
format | Online Article Text |
id | pubmed-4570347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-45703472015-09-17 Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations Bouvier, Brice Duprey, Sonia Claudon, Laurent Dumas, Raphaël Savescu, Adriana Sensors (Basel) Article Magneto-Inertial Measurement Unit sensors (MIMU) display high potential for the quantitative evaluation of upper limb kinematics, as they allow monitoring ambulatory measurements. The sensor-to-segment calibration step, consisting of establishing the relation between MIMU sensors and human segments, plays an important role in the global accuracy of joint angles. The aim of this study was to compare sensor-to-segment calibrations for the MIMU-based estimation of wrist, elbow, and shoulder joint angles, by examining trueness (“close to the reference”) and precision (reproducibility) validity criteria. Ten subjects performed five sessions with three different operators. Three classes of calibrations were studied: segment axes equal to technical MIMU axes (TECH), segment axes generated during a static pose (STATIC), and those generated during functional movements (FUNCT). The calibrations were compared during the maximal uniaxial movements of each joint, plus an extra multi-joint movement. Generally, joint angles presented good trueness and very good precision in the range 5°–10°. Only small discrepancy between calibrations was highlighted, with the exception of a few cases. The very good overall accuracy (trueness and precision) of MIMU-based joint angle data seems to be more dependent on the level of rigor of the experimental procedure (operator training) than on the choice of calibration itself. MDPI 2015-07-31 /pmc/articles/PMC4570347/ /pubmed/26263993 http://dx.doi.org/10.3390/s150818813 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bouvier, Brice Duprey, Sonia Claudon, Laurent Dumas, Raphaël Savescu, Adriana Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations |
title | Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations |
title_full | Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations |
title_fullStr | Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations |
title_full_unstemmed | Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations |
title_short | Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations |
title_sort | upper limb kinematics using inertial and magnetic sensors: comparison of sensor-to-segment calibrations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570347/ https://www.ncbi.nlm.nih.gov/pubmed/26263993 http://dx.doi.org/10.3390/s150818813 |
work_keys_str_mv | AT bouvierbrice upperlimbkinematicsusinginertialandmagneticsensorscomparisonofsensortosegmentcalibrations AT dupreysonia upperlimbkinematicsusinginertialandmagneticsensorscomparisonofsensortosegmentcalibrations AT claudonlaurent upperlimbkinematicsusinginertialandmagneticsensorscomparisonofsensortosegmentcalibrations AT dumasraphael upperlimbkinematicsusinginertialandmagneticsensorscomparisonofsensortosegmentcalibrations AT savescuadriana upperlimbkinematicsusinginertialandmagneticsensorscomparisonofsensortosegmentcalibrations |