Cargando…

Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes

Magnetoelastic sensors as an important type of acoustic wave sensors have shown great promise for a variety of applications. Mass sensitivity is a key parameter to characterize its performance. In this work, the effects of mass load distribution on the mass sensitivity of a magnetoelastic sensor und...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Kewei, Zhang, Lin, Chai, Yuesheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570421/
https://www.ncbi.nlm.nih.gov/pubmed/26295233
http://dx.doi.org/10.3390/s150820267
_version_ 1782390205756473344
author Zhang, Kewei
Zhang, Lin
Chai, Yuesheng
author_facet Zhang, Kewei
Zhang, Lin
Chai, Yuesheng
author_sort Zhang, Kewei
collection PubMed
description Magnetoelastic sensors as an important type of acoustic wave sensors have shown great promise for a variety of applications. Mass sensitivity is a key parameter to characterize its performance. In this work, the effects of mass load distribution on the mass sensitivity of a magnetoelastic sensor under different resonance modes were theoretically investigated using the modal analysis method. The results show that the mass sensitivity and “nodal point” positions are related to the point displacement, which is determined by the motion patterns. The motion patterns are affected by resonance modes and mass load distribution. Asymmetrical mass load distribution causes the motion patterns lose symmetry and leads to the shift of “nodal point”. The mass sensitivity changing with mass load distribution behaves like a sine wave with decaying amplitude and the minimum mass sensitivity appears at the first valley. This study provides certain theoretical guidance for optimizing the mass sensitivity of a magnetoelastic sensor or other acoustic wave based sensors.
format Online
Article
Text
id pubmed-4570421
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-45704212015-09-17 Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes Zhang, Kewei Zhang, Lin Chai, Yuesheng Sensors (Basel) Article Magnetoelastic sensors as an important type of acoustic wave sensors have shown great promise for a variety of applications. Mass sensitivity is a key parameter to characterize its performance. In this work, the effects of mass load distribution on the mass sensitivity of a magnetoelastic sensor under different resonance modes were theoretically investigated using the modal analysis method. The results show that the mass sensitivity and “nodal point” positions are related to the point displacement, which is determined by the motion patterns. The motion patterns are affected by resonance modes and mass load distribution. Asymmetrical mass load distribution causes the motion patterns lose symmetry and leads to the shift of “nodal point”. The mass sensitivity changing with mass load distribution behaves like a sine wave with decaying amplitude and the minimum mass sensitivity appears at the first valley. This study provides certain theoretical guidance for optimizing the mass sensitivity of a magnetoelastic sensor or other acoustic wave based sensors. MDPI 2015-08-18 /pmc/articles/PMC4570421/ /pubmed/26295233 http://dx.doi.org/10.3390/s150820267 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhang, Kewei
Zhang, Lin
Chai, Yuesheng
Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
title Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
title_full Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
title_fullStr Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
title_full_unstemmed Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
title_short Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
title_sort mass load distribution dependence of mass sensitivity of magnetoelastic sensors under different resonance modes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570421/
https://www.ncbi.nlm.nih.gov/pubmed/26295233
http://dx.doi.org/10.3390/s150820267
work_keys_str_mv AT zhangkewei massloaddistributiondependenceofmasssensitivityofmagnetoelasticsensorsunderdifferentresonancemodes
AT zhanglin massloaddistributiondependenceofmasssensitivityofmagnetoelasticsensorsunderdifferentresonancemodes
AT chaiyuesheng massloaddistributiondependenceofmasssensitivityofmagnetoelasticsensorsunderdifferentresonancemodes