Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes
Magnetoelastic sensors as an important type of acoustic wave sensors have shown great promise for a variety of applications. Mass sensitivity is a key parameter to characterize its performance. In this work, the effects of mass load distribution on the mass sensitivity of a magnetoelastic sensor und...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570421/ https://www.ncbi.nlm.nih.gov/pubmed/26295233 http://dx.doi.org/10.3390/s150820267 |
_version_ | 1782390205756473344 |
---|---|
author | Zhang, Kewei Zhang, Lin Chai, Yuesheng |
author_facet | Zhang, Kewei Zhang, Lin Chai, Yuesheng |
author_sort | Zhang, Kewei |
collection | PubMed |
description | Magnetoelastic sensors as an important type of acoustic wave sensors have shown great promise for a variety of applications. Mass sensitivity is a key parameter to characterize its performance. In this work, the effects of mass load distribution on the mass sensitivity of a magnetoelastic sensor under different resonance modes were theoretically investigated using the modal analysis method. The results show that the mass sensitivity and “nodal point” positions are related to the point displacement, which is determined by the motion patterns. The motion patterns are affected by resonance modes and mass load distribution. Asymmetrical mass load distribution causes the motion patterns lose symmetry and leads to the shift of “nodal point”. The mass sensitivity changing with mass load distribution behaves like a sine wave with decaying amplitude and the minimum mass sensitivity appears at the first valley. This study provides certain theoretical guidance for optimizing the mass sensitivity of a magnetoelastic sensor or other acoustic wave based sensors. |
format | Online Article Text |
id | pubmed-4570421 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-45704212015-09-17 Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes Zhang, Kewei Zhang, Lin Chai, Yuesheng Sensors (Basel) Article Magnetoelastic sensors as an important type of acoustic wave sensors have shown great promise for a variety of applications. Mass sensitivity is a key parameter to characterize its performance. In this work, the effects of mass load distribution on the mass sensitivity of a magnetoelastic sensor under different resonance modes were theoretically investigated using the modal analysis method. The results show that the mass sensitivity and “nodal point” positions are related to the point displacement, which is determined by the motion patterns. The motion patterns are affected by resonance modes and mass load distribution. Asymmetrical mass load distribution causes the motion patterns lose symmetry and leads to the shift of “nodal point”. The mass sensitivity changing with mass load distribution behaves like a sine wave with decaying amplitude and the minimum mass sensitivity appears at the first valley. This study provides certain theoretical guidance for optimizing the mass sensitivity of a magnetoelastic sensor or other acoustic wave based sensors. MDPI 2015-08-18 /pmc/articles/PMC4570421/ /pubmed/26295233 http://dx.doi.org/10.3390/s150820267 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Kewei Zhang, Lin Chai, Yuesheng Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes |
title | Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes |
title_full | Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes |
title_fullStr | Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes |
title_full_unstemmed | Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes |
title_short | Mass Load Distribution Dependence of Mass Sensitivity of Magnetoelastic Sensors under Different Resonance Modes |
title_sort | mass load distribution dependence of mass sensitivity of magnetoelastic sensors under different resonance modes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570421/ https://www.ncbi.nlm.nih.gov/pubmed/26295233 http://dx.doi.org/10.3390/s150820267 |
work_keys_str_mv | AT zhangkewei massloaddistributiondependenceofmasssensitivityofmagnetoelasticsensorsunderdifferentresonancemodes AT zhanglin massloaddistributiondependenceofmasssensitivityofmagnetoelasticsensorsunderdifferentresonancemodes AT chaiyuesheng massloaddistributiondependenceofmasssensitivityofmagnetoelasticsensorsunderdifferentresonancemodes |