Cargando…

Validation and cross-cultural adaptation of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25) in Serbian patients

PURPOSE: To test the validity and reliability of the Serbian version of the interviewer-administered format of the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25). METHODS: The Serbian version of NEI VFQ-25 was translated in accordance with standard methods that have been adopte...

Descripción completa

Detalles Bibliográficos
Autores principales: Kovac, Bojan, Vukosavljevic, Miroslav, Djokic Kovac, Jelena, Resan, Mirko, Trajkovic, Goran, Jankovic, Janko, Smiljanic, Milena, Grgurevic, Anita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570616/
https://www.ncbi.nlm.nih.gov/pubmed/26370558
http://dx.doi.org/10.1186/s12955-015-0330-5
Descripción
Sumario:PURPOSE: To test the validity and reliability of the Serbian version of the interviewer-administered format of the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25). METHODS: The Serbian version of NEI VFQ-25 was translated in accordance with standard methods that have been adopted internationally. In order to assess the reliability and validity of the translated NEI VFQ-25, we used a sample of 105 patients with four different chronic ocular diseases. Cronbach’s alpha coefficient was used to assess internal consistency for each subscale. To assess test–retest reliability, intraclass correlation coefficients were used. The test–retest data were obtained from clinically stable patients with age-related cataracts, in surveys performed 2 weeks apart. Rasch analysis was also applied as a modern methods of psychometric assessment of the questionnaire. RESULTS: Four groups of patients were studied and the most prevalent were patients with cataract 40 (38.1 %), followed by diabetic retinopathy 31 (29.5 %), age related macular degeneration 22 (21.0 %) and glaucoma 12 (11.4 %). The overall index score on the NEI VFQ-25 ranged from 65.3 to 67.8 with a mean of 67.4 ± 15.0. Cronbach’s alpha coefficient (index of internal consistency reliability) ranged from 0.643 to 0.889 for the subscales. Evaluation of the validity of the Serbian version of NEI VFQ-25 is presented in the multi-trait–multi-method matrix and all items passed the convergent and discriminant validity tests. Rasch analysis showed a good measurement precision, but also demonstrated misfitting items and multidimensionality of the questionnaire. CONCLUSION: Although traditional validation method indicates that the Serbian version of NEI VFQ-25 is a valid and reliable instrument for the assessment of vision specific QoL in Serbian populations aged 40 years or older, Rasch analysis revealed a substantial weakness of the questionnaire that should be taken into consideration when interpreting the results. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12955-015-0330-5) contains supplementary material, which is available to authorized users.