Cargando…
High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results
PURPOSE: This study is to report clinical and radiological results of high-flexion total knee arthroplasty (TKA) using NexGen LPS-flex system at a minimum 5-year follow-up, and to analyze the implant survivorship based on the results. MATERIALS AND METHODS: A total of 80 patients (118 knees) who und...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Knee Society
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570950/ https://www.ncbi.nlm.nih.gov/pubmed/26389068 http://dx.doi.org/10.5792/ksrr.2015.27.3.156 |
_version_ | 1782390279762870272 |
---|---|
author | Rhee, Seung Joon Hong, Sung Min Suh, Jeung Tak |
author_facet | Rhee, Seung Joon Hong, Sung Min Suh, Jeung Tak |
author_sort | Rhee, Seung Joon |
collection | PubMed |
description | PURPOSE: This study is to report clinical and radiological results of high-flexion total knee arthroplasty (TKA) using NexGen LPS-flex system at a minimum 5-year follow-up, and to analyze the implant survivorship based on the results. MATERIALS AND METHODS: A total of 80 patients (118 knees) who underwent patellar preserving TKA using NexGen LPS-flex implant between February 2007 and February 2008 and could be followed for minimum 5 years were reviewed. The range of motion (ROM), hip-knee-ankle angle, Knee Society Knee score (KSKS), and Knee Society Function score (KSFS) were assessed preoperatively and at the last follow-up and analyzed. Implant position of the femoral and tibial components on the immediate postoperative and last follow-up X-rays were compared. RESULTS: The mean ROM was 110.2°±14.5° (range, 60° to 140°) preoperatively and 132.4°±5.2° (range, 90° to 145°) at the last follow-up. KSKS was 36.9°±6.4° preoperatively and 94.2°±3.2° at the last follow-up. KSFS was 30.5°±5.7° preoperatively and 93.7°±4.1° at the last follow-up. There was no statistically significant change in the implant position measured as α, β, γ, and δ angles at the last follow-up compared to the immediate postoperative values. Radiolucent lines were observed in 13 knees (11%) on the last follow-up X-rays. Revision TKA was performed due to aseptic implant loosening in 1 knee (0.84%), and the survival rate at the 5th postoperative year was 99.2%. CONCLUSIONS: The clinical and radiological outcomes of high-flexion TKA using NexGen LPS-Flex implant design were satisfactory with 99.2% implant survival rate after 5 years of protected activities of daily living. |
format | Online Article Text |
id | pubmed-4570950 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Knee Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-45709502015-09-18 High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results Rhee, Seung Joon Hong, Sung Min Suh, Jeung Tak Knee Surg Relat Res Original Article PURPOSE: This study is to report clinical and radiological results of high-flexion total knee arthroplasty (TKA) using NexGen LPS-flex system at a minimum 5-year follow-up, and to analyze the implant survivorship based on the results. MATERIALS AND METHODS: A total of 80 patients (118 knees) who underwent patellar preserving TKA using NexGen LPS-flex implant between February 2007 and February 2008 and could be followed for minimum 5 years were reviewed. The range of motion (ROM), hip-knee-ankle angle, Knee Society Knee score (KSKS), and Knee Society Function score (KSFS) were assessed preoperatively and at the last follow-up and analyzed. Implant position of the femoral and tibial components on the immediate postoperative and last follow-up X-rays were compared. RESULTS: The mean ROM was 110.2°±14.5° (range, 60° to 140°) preoperatively and 132.4°±5.2° (range, 90° to 145°) at the last follow-up. KSKS was 36.9°±6.4° preoperatively and 94.2°±3.2° at the last follow-up. KSFS was 30.5°±5.7° preoperatively and 93.7°±4.1° at the last follow-up. There was no statistically significant change in the implant position measured as α, β, γ, and δ angles at the last follow-up compared to the immediate postoperative values. Radiolucent lines were observed in 13 knees (11%) on the last follow-up X-rays. Revision TKA was performed due to aseptic implant loosening in 1 knee (0.84%), and the survival rate at the 5th postoperative year was 99.2%. CONCLUSIONS: The clinical and radiological outcomes of high-flexion TKA using NexGen LPS-Flex implant design were satisfactory with 99.2% implant survival rate after 5 years of protected activities of daily living. The Korean Knee Society 2015-09 2015-09-01 /pmc/articles/PMC4570950/ /pubmed/26389068 http://dx.doi.org/10.5792/ksrr.2015.27.3.156 Text en Copyright © 2015 KOREAN KNEE SOCIETY http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Rhee, Seung Joon Hong, Sung Min Suh, Jeung Tak High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results |
title | High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results |
title_full | High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results |
title_fullStr | High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results |
title_full_unstemmed | High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results |
title_short | High-Flexion Total Knee Arthroplasty Using NexGen LPS-Flex System: Minimum 5-year Follow-up Results |
title_sort | high-flexion total knee arthroplasty using nexgen lps-flex system: minimum 5-year follow-up results |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4570950/ https://www.ncbi.nlm.nih.gov/pubmed/26389068 http://dx.doi.org/10.5792/ksrr.2015.27.3.156 |
work_keys_str_mv | AT rheeseungjoon highflexiontotalkneearthroplastyusingnexgenlpsflexsystemminimum5yearfollowupresults AT hongsungmin highflexiontotalkneearthroplastyusingnexgenlpsflexsystemminimum5yearfollowupresults AT suhjeungtak highflexiontotalkneearthroplastyusingnexgenlpsflexsystemminimum5yearfollowupresults |