Cargando…
Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma
BACKGROUND: The purpose of this study was to compare carbon ion radiotherapy (C-ion RT) and stereotactic radiotherapy (SBRT) with photon beams for the treatment of hepatocellular carcinoma (HCC), specifically with regard to the dose volume parameters for target coverage and normal tissue sparing. ME...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4574218/ https://www.ncbi.nlm.nih.gov/pubmed/26377092 http://dx.doi.org/10.1186/s13014-015-0491-8 |
_version_ | 1782390595317137408 |
---|---|
author | Abe, Takanori Saitoh, Jun-ichi Kobayashi, Daijiro Shibuya, Kei Koyama, Yoshinori Shimada, Hirohumi Shirai, Katsuyuki Ohno, Tatsuya Nakano, Takashi |
author_facet | Abe, Takanori Saitoh, Jun-ichi Kobayashi, Daijiro Shibuya, Kei Koyama, Yoshinori Shimada, Hirohumi Shirai, Katsuyuki Ohno, Tatsuya Nakano, Takashi |
author_sort | Abe, Takanori |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to compare carbon ion radiotherapy (C-ion RT) and stereotactic radiotherapy (SBRT) with photon beams for the treatment of hepatocellular carcinoma (HCC), specifically with regard to the dose volume parameters for target coverage and normal tissue sparing. METHODS: Data of 10 patients who were treated using C-ion RT with a total dose of 60 Gy(RBE) in four fractions were used. The virtual plan of SBRT was simulated on the treatment planning computed tomography images of C-ion RT. Dose volume parameters such as minimum dose covering 90 % of the planning target volume (PTV D90), homogeneity index (HI), conformity index (CI), mean liver dose (MLD), volume of the liver receiving 5 to 60 Gy (V5-60), and max point dose (Dmax) of gastrointestinal (GI) tract were calculated from both treatment plans. RESULTS: The PTV D90 was 59.6 ± 0.2 Gy(RBE) in C-ion RT, as compared to 56.6 ± 0.3 Gy in SBRT (p < 0.05). HI and CI were 1.19 ± 0.03 and 0.79 ± 0.06, respectively in C-ion RT, as compared to 1.21 ± 0.01 and 0.37 ± 0.02, respectively in SBRT. Only CI showed a significant difference between two modalities. Mean liver dose was 8.1 ± 1.4 Gy(RBE) in C-ion RT, as compared to 16.1 ± 2.5 Gy in SBRT (p < 0.05). V5 to V50 of liver were higher in SBRT than C-ion RT and significant differences were observed for V5, V10 and V20. Dmax of the GI tract was higher in SBRT than C-ion RT, but did not show a significantly difference. CONCLUSIONS: C-ion RT provides an advantage in both target conformity and normal liver sparing compared with SBRT. |
format | Online Article Text |
id | pubmed-4574218 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45742182015-09-19 Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma Abe, Takanori Saitoh, Jun-ichi Kobayashi, Daijiro Shibuya, Kei Koyama, Yoshinori Shimada, Hirohumi Shirai, Katsuyuki Ohno, Tatsuya Nakano, Takashi Radiat Oncol Research BACKGROUND: The purpose of this study was to compare carbon ion radiotherapy (C-ion RT) and stereotactic radiotherapy (SBRT) with photon beams for the treatment of hepatocellular carcinoma (HCC), specifically with regard to the dose volume parameters for target coverage and normal tissue sparing. METHODS: Data of 10 patients who were treated using C-ion RT with a total dose of 60 Gy(RBE) in four fractions were used. The virtual plan of SBRT was simulated on the treatment planning computed tomography images of C-ion RT. Dose volume parameters such as minimum dose covering 90 % of the planning target volume (PTV D90), homogeneity index (HI), conformity index (CI), mean liver dose (MLD), volume of the liver receiving 5 to 60 Gy (V5-60), and max point dose (Dmax) of gastrointestinal (GI) tract were calculated from both treatment plans. RESULTS: The PTV D90 was 59.6 ± 0.2 Gy(RBE) in C-ion RT, as compared to 56.6 ± 0.3 Gy in SBRT (p < 0.05). HI and CI were 1.19 ± 0.03 and 0.79 ± 0.06, respectively in C-ion RT, as compared to 1.21 ± 0.01 and 0.37 ± 0.02, respectively in SBRT. Only CI showed a significant difference between two modalities. Mean liver dose was 8.1 ± 1.4 Gy(RBE) in C-ion RT, as compared to 16.1 ± 2.5 Gy in SBRT (p < 0.05). V5 to V50 of liver were higher in SBRT than C-ion RT and significant differences were observed for V5, V10 and V20. Dmax of the GI tract was higher in SBRT than C-ion RT, but did not show a significantly difference. CONCLUSIONS: C-ion RT provides an advantage in both target conformity and normal liver sparing compared with SBRT. BioMed Central 2015-09-17 /pmc/articles/PMC4574218/ /pubmed/26377092 http://dx.doi.org/10.1186/s13014-015-0491-8 Text en © Abe et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Abe, Takanori Saitoh, Jun-ichi Kobayashi, Daijiro Shibuya, Kei Koyama, Yoshinori Shimada, Hirohumi Shirai, Katsuyuki Ohno, Tatsuya Nakano, Takashi Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
title | Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
title_full | Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
title_fullStr | Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
title_full_unstemmed | Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
title_short | Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
title_sort | dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4574218/ https://www.ncbi.nlm.nih.gov/pubmed/26377092 http://dx.doi.org/10.1186/s13014-015-0491-8 |
work_keys_str_mv | AT abetakanori dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT saitohjunichi dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT kobayashidaijiro dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT shibuyakei dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT koyamayoshinori dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT shimadahirohumi dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT shiraikatsuyuki dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT ohnotatsuya dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma AT nakanotakashi dosimetriccomparisonofcarbonionradiotherapyandstereotacticbodyradiotherapywithphotonbeamsforthetreatmentofhepatocellularcarcinoma |