Cargando…
Evaluation of Multiband EPI Acquisitions for Resting State fMRI
Functional magnetic resonance imaging (fMRI) and particularly resting state fMRI (rs-fMRI) is widely used to investigate resting state brain networks (RSNs) on the systems level. Echo planar imaging (EPI) is the state-of-the-art imaging technique for most fMRI studies. Therefore, improvements of EPI...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4574400/ https://www.ncbi.nlm.nih.gov/pubmed/26375666 http://dx.doi.org/10.1371/journal.pone.0136961 |
_version_ | 1782390627088990208 |
---|---|
author | Preibisch, Christine Castrillón G., J. Gabriel Bührer, Martin Riedl, Valentin |
author_facet | Preibisch, Christine Castrillón G., J. Gabriel Bührer, Martin Riedl, Valentin |
author_sort | Preibisch, Christine |
collection | PubMed |
description | Functional magnetic resonance imaging (fMRI) and particularly resting state fMRI (rs-fMRI) is widely used to investigate resting state brain networks (RSNs) on the systems level. Echo planar imaging (EPI) is the state-of-the-art imaging technique for most fMRI studies. Therefore, improvements of EPI might lead to increased sensitivity for a large amount of studies performed every day. A number of developments to shorten acquisition time have been recently proposed and the multiband technique, allowing the simultaneous acquisition of multiple slices yielding an equivalent reduction of measurement time, is the most promising among them. While the prospect to significantly reduce acquisition time by means of high multiband acceleration factors (M) appears tempting, signal quality parameters and the sensitivity to detect common RSNs with increasing M-factor have only been partially investigated up to now. In this study, we therefore acquired rs-fMRI data from 20 healthy volunteers to systematically investigate signal characteristics and sensitivity for brain network activity in datasets with increasing M-factor, M = 2 − 4. Combined with an inplane, sensitivity encoding (SENSE), acceleration factor, S = 2, we applied a maximal acceleration factor of 8 (S2×M4). Our results suggest that an M-factor of 2 (total acceleration of 4) only causes negligible SNR decrease but reveals common RSN with increased sensitivity and stability. Further M-factor increase produced random artifacts as revealed by signal quality measures that may affect interpretation of RSNs under common scanning conditions. Given appropriate hardware, a mb-EPI sequence with a total acceleration of 4 significantly reduces overall scanning time and clearly increases sensitivity to detect common RSNs. Together, our results suggest mb-EPI at moderate acceleration factors as a novel standard for fMRI that might increase our understanding of network dynamics in healthy and diseased brains. |
format | Online Article Text |
id | pubmed-4574400 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-45744002015-09-18 Evaluation of Multiband EPI Acquisitions for Resting State fMRI Preibisch, Christine Castrillón G., J. Gabriel Bührer, Martin Riedl, Valentin PLoS One Research Article Functional magnetic resonance imaging (fMRI) and particularly resting state fMRI (rs-fMRI) is widely used to investigate resting state brain networks (RSNs) on the systems level. Echo planar imaging (EPI) is the state-of-the-art imaging technique for most fMRI studies. Therefore, improvements of EPI might lead to increased sensitivity for a large amount of studies performed every day. A number of developments to shorten acquisition time have been recently proposed and the multiband technique, allowing the simultaneous acquisition of multiple slices yielding an equivalent reduction of measurement time, is the most promising among them. While the prospect to significantly reduce acquisition time by means of high multiband acceleration factors (M) appears tempting, signal quality parameters and the sensitivity to detect common RSNs with increasing M-factor have only been partially investigated up to now. In this study, we therefore acquired rs-fMRI data from 20 healthy volunteers to systematically investigate signal characteristics and sensitivity for brain network activity in datasets with increasing M-factor, M = 2 − 4. Combined with an inplane, sensitivity encoding (SENSE), acceleration factor, S = 2, we applied a maximal acceleration factor of 8 (S2×M4). Our results suggest that an M-factor of 2 (total acceleration of 4) only causes negligible SNR decrease but reveals common RSN with increased sensitivity and stability. Further M-factor increase produced random artifacts as revealed by signal quality measures that may affect interpretation of RSNs under common scanning conditions. Given appropriate hardware, a mb-EPI sequence with a total acceleration of 4 significantly reduces overall scanning time and clearly increases sensitivity to detect common RSNs. Together, our results suggest mb-EPI at moderate acceleration factors as a novel standard for fMRI that might increase our understanding of network dynamics in healthy and diseased brains. Public Library of Science 2015-09-16 /pmc/articles/PMC4574400/ /pubmed/26375666 http://dx.doi.org/10.1371/journal.pone.0136961 Text en © 2015 Preibisch et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Preibisch, Christine Castrillón G., J. Gabriel Bührer, Martin Riedl, Valentin Evaluation of Multiband EPI Acquisitions for Resting State fMRI |
title | Evaluation of Multiband EPI Acquisitions for Resting State fMRI |
title_full | Evaluation of Multiband EPI Acquisitions for Resting State fMRI |
title_fullStr | Evaluation of Multiband EPI Acquisitions for Resting State fMRI |
title_full_unstemmed | Evaluation of Multiband EPI Acquisitions for Resting State fMRI |
title_short | Evaluation of Multiband EPI Acquisitions for Resting State fMRI |
title_sort | evaluation of multiband epi acquisitions for resting state fmri |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4574400/ https://www.ncbi.nlm.nih.gov/pubmed/26375666 http://dx.doi.org/10.1371/journal.pone.0136961 |
work_keys_str_mv | AT preibischchristine evaluationofmultibandepiacquisitionsforrestingstatefmri AT castrillongjgabriel evaluationofmultibandepiacquisitionsforrestingstatefmri AT buhrermartin evaluationofmultibandepiacquisitionsforrestingstatefmri AT riedlvalentin evaluationofmultibandepiacquisitionsforrestingstatefmri |