Cargando…

Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear

OBJECTIVE: Imaging cochlear, vestibular, and 8th cranial nerve abnormalities remains a challenge. In this study, the membranous and osseous labyrinths of the wild type mouse inner ear were examined using volumetric data from ultra high-field magnetic resonance imaging (MRI) with gadolinium contrast...

Descripción completa

Detalles Bibliográficos
Autores principales: Counter, S. Allen, Damberg, Peter, Aski, Sahar Nikkhou, Nagy, Kálmán, Berglin, Cecilia Engmér, Laurell, Göran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4578136/
https://www.ncbi.nlm.nih.gov/pubmed/26401173
http://dx.doi.org/10.2174/1874440001509010007
_version_ 1782391071089623040
author Counter, S. Allen
Damberg, Peter
Aski, Sahar Nikkhou
Nagy, Kálmán
Berglin, Cecilia Engmér
Laurell, Göran
author_facet Counter, S. Allen
Damberg, Peter
Aski, Sahar Nikkhou
Nagy, Kálmán
Berglin, Cecilia Engmér
Laurell, Göran
author_sort Counter, S. Allen
collection PubMed
description OBJECTIVE: Imaging cochlear, vestibular, and 8th cranial nerve abnormalities remains a challenge. In this study, the membranous and osseous labyrinths of the wild type mouse inner ear were examined using volumetric data from ultra high-field magnetic resonance imaging (MRI) with gadolinium contrast at 9.4 Tesla and high-resolution micro-computed tomography (µCT) to visualize the scalae and vestibular apparatus, and to establish imaging protocols and parameters for comparative analysis of the normal and mutant mouse inner ear. METHODS: For in vivo MRI acquisition, animals were placed in a Milleped coil situated in the isocenter of a horizontal 9.4 T Varian magnet. For µCT examination, cone beam scans were performed ex vivo following MRI using the µCT component of a nanoScan PET/CT in vivo scanner. RESULTS: The fusion of Gd enhanced high field MRI and high-resolution µCT scans revealed the dynamic membranous labyrinth of the perilymphatic fluid filled scala tympani and scala vestibule of the cochlea, and semicircular canals of the vestibular apparatus, within the µCT visualized contours of the contiguous osseous labyrinth. The ex vivo µCT segmentation revealed the surface contours and structural morphology of each cochlea turn and the semicircular canals in 3 planes. CONCLUSIONS: The fusion of ultra high-field MRI and high-resolution µCT imaging techniques were complementary, and provided high-resolution dynamic and static visualization of the complex morphological features of the normal mouse inner ear structures, which may offer a valuable approach for the investigation of cochlear and vestibular abnormalities that are associated with birth defects related to genetic inner ear disorders in humans.
format Online
Article
Text
id pubmed-4578136
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-45781362015-09-23 Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear Counter, S. Allen Damberg, Peter Aski, Sahar Nikkhou Nagy, Kálmán Berglin, Cecilia Engmér Laurell, Göran Open Neuroimag J Article OBJECTIVE: Imaging cochlear, vestibular, and 8th cranial nerve abnormalities remains a challenge. In this study, the membranous and osseous labyrinths of the wild type mouse inner ear were examined using volumetric data from ultra high-field magnetic resonance imaging (MRI) with gadolinium contrast at 9.4 Tesla and high-resolution micro-computed tomography (µCT) to visualize the scalae and vestibular apparatus, and to establish imaging protocols and parameters for comparative analysis of the normal and mutant mouse inner ear. METHODS: For in vivo MRI acquisition, animals were placed in a Milleped coil situated in the isocenter of a horizontal 9.4 T Varian magnet. For µCT examination, cone beam scans were performed ex vivo following MRI using the µCT component of a nanoScan PET/CT in vivo scanner. RESULTS: The fusion of Gd enhanced high field MRI and high-resolution µCT scans revealed the dynamic membranous labyrinth of the perilymphatic fluid filled scala tympani and scala vestibule of the cochlea, and semicircular canals of the vestibular apparatus, within the µCT visualized contours of the contiguous osseous labyrinth. The ex vivo µCT segmentation revealed the surface contours and structural morphology of each cochlea turn and the semicircular canals in 3 planes. CONCLUSIONS: The fusion of ultra high-field MRI and high-resolution µCT imaging techniques were complementary, and provided high-resolution dynamic and static visualization of the complex morphological features of the normal mouse inner ear structures, which may offer a valuable approach for the investigation of cochlear and vestibular abnormalities that are associated with birth defects related to genetic inner ear disorders in humans. Bentham Open 2015-07-31 /pmc/articles/PMC4578136/ /pubmed/26401173 http://dx.doi.org/10.2174/1874440001509010007 Text en © Counter et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Counter, S. Allen
Damberg, Peter
Aski, Sahar Nikkhou
Nagy, Kálmán
Berglin, Cecilia Engmér
Laurell, Göran
Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear
title Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear
title_full Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear
title_fullStr Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear
title_full_unstemmed Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear
title_short Experimental Fusion of Contrast Enhanced High-Field Magnetic Resonance Imaging and High-Resolution Micro-Computed Tomography in Imaging the Mouse Inner Ear
title_sort experimental fusion of contrast enhanced high-field magnetic resonance imaging and high-resolution micro-computed tomography in imaging the mouse inner ear
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4578136/
https://www.ncbi.nlm.nih.gov/pubmed/26401173
http://dx.doi.org/10.2174/1874440001509010007
work_keys_str_mv AT countersallen experimentalfusionofcontrastenhancedhighfieldmagneticresonanceimagingandhighresolutionmicrocomputedtomographyinimagingthemouseinnerear
AT dambergpeter experimentalfusionofcontrastenhancedhighfieldmagneticresonanceimagingandhighresolutionmicrocomputedtomographyinimagingthemouseinnerear
AT askisaharnikkhou experimentalfusionofcontrastenhancedhighfieldmagneticresonanceimagingandhighresolutionmicrocomputedtomographyinimagingthemouseinnerear
AT nagykalman experimentalfusionofcontrastenhancedhighfieldmagneticresonanceimagingandhighresolutionmicrocomputedtomographyinimagingthemouseinnerear
AT berglinceciliaengmer experimentalfusionofcontrastenhancedhighfieldmagneticresonanceimagingandhighresolutionmicrocomputedtomographyinimagingthemouseinnerear
AT laurellgoran experimentalfusionofcontrastenhancedhighfieldmagneticresonanceimagingandhighresolutionmicrocomputedtomographyinimagingthemouseinnerear