Cargando…
Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population
BACKGROUND: Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4579101/ https://www.ncbi.nlm.nih.gov/pubmed/26354345 http://dx.doi.org/10.3343/alm.2015.35.6.578 |
_version_ | 1782391213546012672 |
---|---|
author | Kim, Borahm Lee, Mi-Na Park, Hyung-Doo Kim, Jong Won Chang, Yun Sil Park, Won Soon Lee, Soo-Youn |
author_facet | Kim, Borahm Lee, Mi-Na Park, Hyung-Doo Kim, Jong Won Chang, Yun Sil Park, Won Soon Lee, Soo-Youn |
author_sort | Kim, Borahm |
collection | PubMed |
description | BACKGROUND: Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because of limited data on its use in the Korean population, LC-MS/MS has not yet been incorporated into newborn screening programs in this region. The present study aims to develop and validate an LC-MS/MS method for the simultaneous determination of seven steroids in dried blood spots (DBS) for CAH screening, and to define age-specific reference intervals in the Korean population. METHODS: We developed and validated an LC-MS/MS method to determine the reference intervals of cortisol, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, and 11-deoxycorticosterone simultaneously in 453 DBS samples. The samples were from Korean subjects stratified by age group (78 full-term neonates, 76 premature neonates, 89 children, and 100 adults). RESULTS: The accuracy, precision, matrix effects, and extraction recovery were satisfactory for all the steroids at three concentrations; values of intra- and inter-day precision coefficients of variance, bias, and recovery were 0.7-7.7%, -1.5-9.8%, and 49.3-97.5%, respectively. The linearity range was 1-100 ng/mL for cortisol and 0.5-50 ng/mL for other steroids (R(2)>0.99). The reference intervals were in agreement with the previous reports. CONCLUSIONS: This LC-MS/MS method and the reference intervals validated in the Korean population can be successfully applied to analyze seven steroids in DBS for the diagnosis of CAH. |
format | Online Article Text |
id | pubmed-4579101 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-45791012015-11-01 Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population Kim, Borahm Lee, Mi-Na Park, Hyung-Doo Kim, Jong Won Chang, Yun Sil Park, Won Soon Lee, Soo-Youn Ann Lab Med Original Article BACKGROUND: Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because of limited data on its use in the Korean population, LC-MS/MS has not yet been incorporated into newborn screening programs in this region. The present study aims to develop and validate an LC-MS/MS method for the simultaneous determination of seven steroids in dried blood spots (DBS) for CAH screening, and to define age-specific reference intervals in the Korean population. METHODS: We developed and validated an LC-MS/MS method to determine the reference intervals of cortisol, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, and 11-deoxycorticosterone simultaneously in 453 DBS samples. The samples were from Korean subjects stratified by age group (78 full-term neonates, 76 premature neonates, 89 children, and 100 adults). RESULTS: The accuracy, precision, matrix effects, and extraction recovery were satisfactory for all the steroids at three concentrations; values of intra- and inter-day precision coefficients of variance, bias, and recovery were 0.7-7.7%, -1.5-9.8%, and 49.3-97.5%, respectively. The linearity range was 1-100 ng/mL for cortisol and 0.5-50 ng/mL for other steroids (R(2)>0.99). The reference intervals were in agreement with the previous reports. CONCLUSIONS: This LC-MS/MS method and the reference intervals validated in the Korean population can be successfully applied to analyze seven steroids in DBS for the diagnosis of CAH. The Korean Society for Laboratory Medicine 2015-11 2015-09-01 /pmc/articles/PMC4579101/ /pubmed/26354345 http://dx.doi.org/10.3343/alm.2015.35.6.578 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Borahm Lee, Mi-Na Park, Hyung-Doo Kim, Jong Won Chang, Yun Sil Park, Won Soon Lee, Soo-Youn Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population |
title | Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population |
title_full | Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population |
title_fullStr | Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population |
title_full_unstemmed | Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population |
title_short | Dried Blood Spot Testing for Seven Steroids Using Liquid Chromatography-Tandem Mass Spectrometry With Reference Interval Determination in the Korean Population |
title_sort | dried blood spot testing for seven steroids using liquid chromatography-tandem mass spectrometry with reference interval determination in the korean population |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4579101/ https://www.ncbi.nlm.nih.gov/pubmed/26354345 http://dx.doi.org/10.3343/alm.2015.35.6.578 |
work_keys_str_mv | AT kimborahm driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation AT leemina driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation AT parkhyungdoo driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation AT kimjongwon driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation AT changyunsil driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation AT parkwonsoon driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation AT leesooyoun driedbloodspottestingforsevensteroidsusingliquidchromatographytandemmassspectrometrywithreferenceintervaldeterminationinthekoreanpopulation |