Cargando…
Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories
Quality control (QC) processes are being performed in the majority of clinical microbiology laboratories to ensure the performance of microbial identification and antimicrobial susceptibility testing by using ATCC strains. To obtain these ATCC strains, some inconveniences are encountered concerning...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4579109/ https://www.ncbi.nlm.nih.gov/pubmed/26354353 http://dx.doi.org/10.3343/alm.2015.35.6.635 |
_version_ | 1782391215398846464 |
---|---|
author | Hong, Sung Kuk Choi, Seung Jun Shin, Saeam Lee, Wonmok Pinto, Naina Shin, Nari Lee, Kwangjun Hong, Seong Geun Kim, Young Ah Lee, Hyukmin Kim, Heejung Song, Wonkeun Lee, Sun Hwa Yong, Dongeun Lee, Kyungwon Chong, Yunsop |
author_facet | Hong, Sung Kuk Choi, Seung Jun Shin, Saeam Lee, Wonmok Pinto, Naina Shin, Nari Lee, Kwangjun Hong, Seong Geun Kim, Young Ah Lee, Hyukmin Kim, Heejung Song, Wonkeun Lee, Sun Hwa Yong, Dongeun Lee, Kyungwon Chong, Yunsop |
author_sort | Hong, Sung Kuk |
collection | PubMed |
description | Quality control (QC) processes are being performed in the majority of clinical microbiology laboratories to ensure the performance of microbial identification and antimicrobial susceptibility testing by using ATCC strains. To obtain these ATCC strains, some inconveniences are encountered concerning the purchase cost of the strains and the shipping time required. This study was focused on constructing a database of reference strains for QC processes using domestic bacterial strains, concentrating primarily on antimicrobial susceptibility testing. Three strains (Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus) that showed legible results in preliminary testing were selected. The minimal inhibitory concentrations (MICs) and zone diameters (ZDs) of eight antimicrobials for each strain were determined according to the CLSI M23. All resulting MIC and ZD ranges included at least 95% of the data. The ZD QC ranges obtained by using the CLSI method were less than 12 mm, and the MIC QC ranges extended no more than five dilutions. This study is a preliminary attempt to construct a bank of Korean QC strains. With further studies, a positive outcome toward cost and time reduction can be anticipated. |
format | Online Article Text |
id | pubmed-4579109 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-45791092015-11-01 Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories Hong, Sung Kuk Choi, Seung Jun Shin, Saeam Lee, Wonmok Pinto, Naina Shin, Nari Lee, Kwangjun Hong, Seong Geun Kim, Young Ah Lee, Hyukmin Kim, Heejung Song, Wonkeun Lee, Sun Hwa Yong, Dongeun Lee, Kyungwon Chong, Yunsop Ann Lab Med Brief Communication Quality control (QC) processes are being performed in the majority of clinical microbiology laboratories to ensure the performance of microbial identification and antimicrobial susceptibility testing by using ATCC strains. To obtain these ATCC strains, some inconveniences are encountered concerning the purchase cost of the strains and the shipping time required. This study was focused on constructing a database of reference strains for QC processes using domestic bacterial strains, concentrating primarily on antimicrobial susceptibility testing. Three strains (Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus) that showed legible results in preliminary testing were selected. The minimal inhibitory concentrations (MICs) and zone diameters (ZDs) of eight antimicrobials for each strain were determined according to the CLSI M23. All resulting MIC and ZD ranges included at least 95% of the data. The ZD QC ranges obtained by using the CLSI method were less than 12 mm, and the MIC QC ranges extended no more than five dilutions. This study is a preliminary attempt to construct a bank of Korean QC strains. With further studies, a positive outcome toward cost and time reduction can be anticipated. The Korean Society for Laboratory Medicine 2015-11 2015-09-01 /pmc/articles/PMC4579109/ /pubmed/26354353 http://dx.doi.org/10.3343/alm.2015.35.6.635 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Brief Communication Hong, Sung Kuk Choi, Seung Jun Shin, Saeam Lee, Wonmok Pinto, Naina Shin, Nari Lee, Kwangjun Hong, Seong Geun Kim, Young Ah Lee, Hyukmin Kim, Heejung Song, Wonkeun Lee, Sun Hwa Yong, Dongeun Lee, Kyungwon Chong, Yunsop Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories |
title | Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories |
title_full | Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories |
title_fullStr | Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories |
title_full_unstemmed | Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories |
title_short | Establishing Quality Control Ranges for Antimicrobial Susceptibility Testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus: A Cornerstone to Develop Reference Strains for Korean Clinical Microbiology Laboratories |
title_sort | establishing quality control ranges for antimicrobial susceptibility testing of escherichia coli, pseudomonas aeruginosa, and staphylococcus aureus: a cornerstone to develop reference strains for korean clinical microbiology laboratories |
topic | Brief Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4579109/ https://www.ncbi.nlm.nih.gov/pubmed/26354353 http://dx.doi.org/10.3343/alm.2015.35.6.635 |
work_keys_str_mv | AT hongsungkuk establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT choiseungjun establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT shinsaeam establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT leewonmok establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT pintonaina establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT shinnari establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT leekwangjun establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT hongseonggeun establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT kimyoungah establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT leehyukmin establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT kimheejung establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT songwonkeun establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT leesunhwa establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT yongdongeun establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT leekyungwon establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories AT chongyunsop establishingqualitycontrolrangesforantimicrobialsusceptibilitytestingofescherichiacolipseudomonasaeruginosaandstaphylococcusaureusacornerstonetodevelopreferencestrainsforkoreanclinicalmicrobiologylaboratories |