Cargando…

Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults

The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measuremen...

Descripción completa

Detalles Bibliográficos
Autores principales: Durajska, Kaja, Januszkiewicz, Emilia, Szmygel, Łukasz, Kosiak, Wojciech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Communications Sp. z o.o. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4579687/
https://www.ncbi.nlm.nih.gov/pubmed/26675322
http://dx.doi.org/10.15557/JoU.2014.0027
_version_ 1782391299578527744
author Durajska, Kaja
Januszkiewicz, Emilia
Szmygel, Łukasz
Kosiak, Wojciech
author_facet Durajska, Kaja
Januszkiewicz, Emilia
Szmygel, Łukasz
Kosiak, Wojciech
author_sort Durajska, Kaja
collection PubMed
description The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta diameter index in a sonographic hydration assessment. The study enrolled 50 young students at the age of 19–26 (the median age was 22.95) including 27 women and 23 men. The volunteers were examined in the supine position with GE Logiq 7 system and a convex transducer with the frequency of 2–5 MHz. The measurements were performed in the longitudinal and transverse planes by two inexperienced examiners – the authors of this paper, following a four-hour training conducted by an experienced sonographer. The longitudinal values of the inferior vena cava/aorta diameter index obtained in this study were similar to those found in the literature. The reference value for the inferior vena cava/aorta index determined by Kosiak et al., which constituted 1.2 ± 2 SD, for SD = 0.17, was similar to the values obtained by the authors of this paper which equaled 1.2286 ± 2 SD, for SD = 0.2. The article presented below proves that measuring the inferior vena cava/aorta diameter index is not a complex examination and it may be performed by physicians with no sonographic experience. Furthermore, the paper demonstrates that the inferior vena cava/aorta diameter index measured in the transverse plane is similar to the inferior vena cava/aorta diameter index determined in the longitudinal plane. Thus, both measurements may be used interchangeably to assess the hydration status of patients.
format Online
Article
Text
id pubmed-4579687
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medical Communications Sp. z o.o.
record_format MEDLINE/PubMed
spelling pubmed-45796872015-12-15 Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults Durajska, Kaja Januszkiewicz, Emilia Szmygel, Łukasz Kosiak, Wojciech J Ultrason Original Paper The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta diameter index in a sonographic hydration assessment. The study enrolled 50 young students at the age of 19–26 (the median age was 22.95) including 27 women and 23 men. The volunteers were examined in the supine position with GE Logiq 7 system and a convex transducer with the frequency of 2–5 MHz. The measurements were performed in the longitudinal and transverse planes by two inexperienced examiners – the authors of this paper, following a four-hour training conducted by an experienced sonographer. The longitudinal values of the inferior vena cava/aorta diameter index obtained in this study were similar to those found in the literature. The reference value for the inferior vena cava/aorta index determined by Kosiak et al., which constituted 1.2 ± 2 SD, for SD = 0.17, was similar to the values obtained by the authors of this paper which equaled 1.2286 ± 2 SD, for SD = 0.2. The article presented below proves that measuring the inferior vena cava/aorta diameter index is not a complex examination and it may be performed by physicians with no sonographic experience. Furthermore, the paper demonstrates that the inferior vena cava/aorta diameter index measured in the transverse plane is similar to the inferior vena cava/aorta diameter index determined in the longitudinal plane. Thus, both measurements may be used interchangeably to assess the hydration status of patients. Medical Communications Sp. z o.o. 2014-09-30 2014-09 /pmc/articles/PMC4579687/ /pubmed/26675322 http://dx.doi.org/10.15557/JoU.2014.0027 Text en 2014 Polish Ultrasound Society. Published by Medical Communications Sp. z o.o. All rights reserved. http://creativecommons.org/licenses/by-nc-nd This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License (CC BY-NC-ND). Reproduction is permitted for personal, educational, non-commercial use, provided that the original article is in whole, unmodified, and properly cited.
spellingShingle Original Paper
Durajska, Kaja
Januszkiewicz, Emilia
Szmygel, Łukasz
Kosiak, Wojciech
Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
title Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
title_full Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
title_fullStr Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
title_full_unstemmed Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
title_short Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
title_sort inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4579687/
https://www.ncbi.nlm.nih.gov/pubmed/26675322
http://dx.doi.org/10.15557/JoU.2014.0027
work_keys_str_mv AT durajskakaja inferiorvenacavaaortadiameterindexintheassessmentofthebodyfluidstatusacomparativestudyofmeasurementsperformedbyexperiencedandinexperiencedexaminersinagroupofyoungadults
AT januszkiewiczemilia inferiorvenacavaaortadiameterindexintheassessmentofthebodyfluidstatusacomparativestudyofmeasurementsperformedbyexperiencedandinexperiencedexaminersinagroupofyoungadults
AT szmygelłukasz inferiorvenacavaaortadiameterindexintheassessmentofthebodyfluidstatusacomparativestudyofmeasurementsperformedbyexperiencedandinexperiencedexaminersinagroupofyoungadults
AT kosiakwojciech inferiorvenacavaaortadiameterindexintheassessmentofthebodyfluidstatusacomparativestudyofmeasurementsperformedbyexperiencedandinexperiencedexaminersinagroupofyoungadults