Comparative Accuracy of the InBios Scrub Typhus Detect IgM Rapid Test for the Detection of IgM Antibodies by Using Conventional Serology
This study investigated the comparative accuracy of a recombinant 56-kDa type-specific antigen-based rapid diagnostic test (RDT) for scrub typhus for the detection of IgM antibodies by using conventional serology in well-characterized serum samples from undifferentiated febrile illness patients. The...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Society for Microbiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4580738/ https://www.ncbi.nlm.nih.gov/pubmed/26291089 http://dx.doi.org/10.1128/CVI.00390-15 |
Sumario: | This study investigated the comparative accuracy of a recombinant 56-kDa type-specific antigen-based rapid diagnostic test (RDT) for scrub typhus for the detection of IgM antibodies by using conventional serology in well-characterized serum samples from undifferentiated febrile illness patients. The RDT showed high specificity and promising comparative accuracy, with 82% sensitivity and 98% specificity for samples defined positive at an IgM indirect immunofluorescence assay positivity cutoff titer of ≥1:1,600 versus 92% and 95% at ≥1:6,400, respectively. |
---|