Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents

To establish hand-held dynamometry (HHD) maximal isometric muscle torque (MIT) reference values for children and adolescents who are developing typically. METHODS: The MIT of 10 upper and lower limb muscle groups was assessed in 351 Caucasian youth (4 years 2 months to 17 years) using a standardized...

Descripción completa

Detalles Bibliográficos
Autores principales: Hébert, Luc J., Maltais, Désirée B., Lepage, Céline, Saulnier, Joanne, Crête, Mélanie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4581449/
https://www.ncbi.nlm.nih.gov/pubmed/26397089
http://dx.doi.org/10.1097/PEP.0000000000000179
Descripción
Sumario:To establish hand-held dynamometry (HHD) maximal isometric muscle torque (MIT) reference values for children and adolescents who are developing typically. METHODS: The MIT of 10 upper and lower limb muscle groups was assessed in 351 Caucasian youth (4 years 2 months to 17 years) using a standardized HHD protocol, previously shown to be feasible, valid, and reliable. RESULTS: The mean MIT and 95% confidence interval of the mean for all muscle groups, for each of the 14 age groups (1 year age span for each group), and for each sex, were reported in both absolute (Nm) and normalized (Nm/kg) values. CONCLUSION: These HHD reference values may be helpful in the identification of muscle strength impairments in several pediatric populations, especially when bilateral impairments are present.