Cargando…
Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required
INTRODUCTION: In dialysis centers both nephrologists and nurses are faced with the challenge of ensuring reliable and efficient care accordance with the clinical guideline. Hemodialysis adequacy monitoring information system therefore enable the automation of tasks, which ultimately allows doctors a...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AVICENA, d.o.o., Sarajevo
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4584089/ https://www.ncbi.nlm.nih.gov/pubmed/26483599 http://dx.doi.org/10.5455/aim.2015.23.239-242 |
_version_ | 1782391939185770496 |
---|---|
author | Jebraeily, Mohamad Ghazisaeidi, Marjan Safdari, Reza Makhdoomi, Khadijeh Rahimi, Bahlol |
author_facet | Jebraeily, Mohamad Ghazisaeidi, Marjan Safdari, Reza Makhdoomi, Khadijeh Rahimi, Bahlol |
author_sort | Jebraeily, Mohamad |
collection | PubMed |
description | INTRODUCTION: In dialysis centers both nephrologists and nurses are faced with the challenge of ensuring reliable and efficient care accordance with the clinical guideline. Hemodialysis adequacy monitoring information system therefore enable the automation of tasks, which ultimately allows doctors and nursing staff more time to dedicate to the individual treatment of patients. Development of the information systems in healthcare has made the use of the Minimum data set inevitable. The purpose of this study was determined MDS and capabilities required in hemodialysis adequacy monitoring information system. METHOD AND MATERIALS: This is a cross-sectional survey conducted with participation of 320 nephrology specialists in 2015. Data were collected using an electronic questionnaire which was estimated as both reliable and valid. The data were analyzed by SPSS software descriptive statistics and analytical statistics. RESULTS: Overall 42 data elements were determined as final set in 4 major categories (patient demographics, medical history, treatment plan and hemodialysis adequacy). The most capabilities required of hemodialysis information system were related to calculate of dialysis adequacy Index (4.80), advice optimal dose of dialysis for each patient (4.63), Easy access to information system without restrictions of time and place (4.61), providing alerts when dialysis adequacy index below the standard (4.55) and Interchange to other information systems in hospitals (4.46) respectively. CONCLUSION: In design and implementation of information systems focus on MDS and identification IS capabilities based on the users’ needs, due to the wide participation users and also the success of the information system. Therefore it is necessary that MDS evaluated carefully with regard to the intended uses of the data. Also information systems based on capabilities the ability to meet the needs of their users. |
format | Online Article Text |
id | pubmed-4584089 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | AVICENA, d.o.o., Sarajevo |
record_format | MEDLINE/PubMed |
spelling | pubmed-45840892015-10-19 Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required Jebraeily, Mohamad Ghazisaeidi, Marjan Safdari, Reza Makhdoomi, Khadijeh Rahimi, Bahlol Acta Inform Med Professional Paper INTRODUCTION: In dialysis centers both nephrologists and nurses are faced with the challenge of ensuring reliable and efficient care accordance with the clinical guideline. Hemodialysis adequacy monitoring information system therefore enable the automation of tasks, which ultimately allows doctors and nursing staff more time to dedicate to the individual treatment of patients. Development of the information systems in healthcare has made the use of the Minimum data set inevitable. The purpose of this study was determined MDS and capabilities required in hemodialysis adequacy monitoring information system. METHOD AND MATERIALS: This is a cross-sectional survey conducted with participation of 320 nephrology specialists in 2015. Data were collected using an electronic questionnaire which was estimated as both reliable and valid. The data were analyzed by SPSS software descriptive statistics and analytical statistics. RESULTS: Overall 42 data elements were determined as final set in 4 major categories (patient demographics, medical history, treatment plan and hemodialysis adequacy). The most capabilities required of hemodialysis information system were related to calculate of dialysis adequacy Index (4.80), advice optimal dose of dialysis for each patient (4.63), Easy access to information system without restrictions of time and place (4.61), providing alerts when dialysis adequacy index below the standard (4.55) and Interchange to other information systems in hospitals (4.46) respectively. CONCLUSION: In design and implementation of information systems focus on MDS and identification IS capabilities based on the users’ needs, due to the wide participation users and also the success of the information system. Therefore it is necessary that MDS evaluated carefully with regard to the intended uses of the data. Also information systems based on capabilities the ability to meet the needs of their users. AVICENA, d.o.o., Sarajevo 2015-07-30 2015-08 /pmc/articles/PMC4584089/ /pubmed/26483599 http://dx.doi.org/10.5455/aim.2015.23.239-242 Text en Copyright: © 2015 Mohamad Jebraeily, Marjan Ghazisaeidi, Reza Safdari, Khadijeh Makhdoomi, Bahlol Rahimi http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Professional Paper Jebraeily, Mohamad Ghazisaeidi, Marjan Safdari, Reza Makhdoomi, Khadijeh Rahimi, Bahlol Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required |
title | Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required |
title_full | Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required |
title_fullStr | Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required |
title_full_unstemmed | Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required |
title_short | Hemodialysis Adequacy Monitoring Information System: Minimum Data Set and Capabilities Required |
title_sort | hemodialysis adequacy monitoring information system: minimum data set and capabilities required |
topic | Professional Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4584089/ https://www.ncbi.nlm.nih.gov/pubmed/26483599 http://dx.doi.org/10.5455/aim.2015.23.239-242 |
work_keys_str_mv | AT jebraeilymohamad hemodialysisadequacymonitoringinformationsystemminimumdatasetandcapabilitiesrequired AT ghazisaeidimarjan hemodialysisadequacymonitoringinformationsystemminimumdatasetandcapabilitiesrequired AT safdarireza hemodialysisadequacymonitoringinformationsystemminimumdatasetandcapabilitiesrequired AT makhdoomikhadijeh hemodialysisadequacymonitoringinformationsystemminimumdatasetandcapabilitiesrequired AT rahimibahlol hemodialysisadequacymonitoringinformationsystemminimumdatasetandcapabilitiesrequired |