Cargando…
Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients
BACKGROUND: Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without know...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hellenic Society of Gastroenterology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4585393/ https://www.ncbi.nlm.nih.gov/pubmed/26423317 |
_version_ | 1782392196904779776 |
---|---|
author | Papamichael, Konstantinos Karatzas, Pantelis Theodoropoulos, Ioannis Kyriakos, Nikos Archavlis, Emmanuel Mantzaris, Gerasimos J. |
author_facet | Papamichael, Konstantinos Karatzas, Pantelis Theodoropoulos, Ioannis Kyriakos, Nikos Archavlis, Emmanuel Mantzaris, Gerasimos J. |
author_sort | Papamichael, Konstantinos |
collection | PubMed |
description | BACKGROUND: Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn’s disease (CD). METHODS: This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. RESULTS: Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. CONCLUSION: Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients. |
format | Online Article Text |
id | pubmed-4585393 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hellenic Society of Gastroenterology |
record_format | MEDLINE/PubMed |
spelling | pubmed-45853932015-10-01 Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients Papamichael, Konstantinos Karatzas, Pantelis Theodoropoulos, Ioannis Kyriakos, Nikos Archavlis, Emmanuel Mantzaris, Gerasimos J. Ann Gastroenterol Original Article BACKGROUND: Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn’s disease (CD). METHODS: This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. RESULTS: Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. CONCLUSION: Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients. Hellenic Society of Gastroenterology 2015 /pmc/articles/PMC4585393/ /pubmed/26423317 Text en Copyright: © Hellenic Society of Gastroenterology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Papamichael, Konstantinos Karatzas, Pantelis Theodoropoulos, Ioannis Kyriakos, Nikos Archavlis, Emmanuel Mantzaris, Gerasimos J. Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients |
title | Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients |
title_full | Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients |
title_fullStr | Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients |
title_full_unstemmed | Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients |
title_short | Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients |
title_sort | simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-crohn’s disease patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4585393/ https://www.ncbi.nlm.nih.gov/pubmed/26423317 |
work_keys_str_mv | AT papamichaelkonstantinos simethiconeadjuncttopolyethyleneglycolimprovessmallbowelcapsuleendoscopyimaginginnoncrohnsdiseasepatients AT karatzaspantelis simethiconeadjuncttopolyethyleneglycolimprovessmallbowelcapsuleendoscopyimaginginnoncrohnsdiseasepatients AT theodoropoulosioannis simethiconeadjuncttopolyethyleneglycolimprovessmallbowelcapsuleendoscopyimaginginnoncrohnsdiseasepatients AT kyriakosnikos simethiconeadjuncttopolyethyleneglycolimprovessmallbowelcapsuleendoscopyimaginginnoncrohnsdiseasepatients AT archavlisemmanuel simethiconeadjuncttopolyethyleneglycolimprovessmallbowelcapsuleendoscopyimaginginnoncrohnsdiseasepatients AT mantzarisgerasimosj simethiconeadjuncttopolyethyleneglycolimprovessmallbowelcapsuleendoscopyimaginginnoncrohnsdiseasepatients |