Cargando…

Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test

The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber. NEW METHODS: We developed novel data acquisition hardware and s...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hung Tae, Uchimoto, Kazuhiro, Duellman, Tyler, Yang, Jay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4586949/
https://www.ncbi.nlm.nih.gov/pubmed/26143745
http://dx.doi.org/10.1016/j.physbeh.2015.06.035
_version_ 1782392452268687360
author Kim, Hung Tae
Uchimoto, Kazuhiro
Duellman, Tyler
Yang, Jay
author_facet Kim, Hung Tae
Uchimoto, Kazuhiro
Duellman, Tyler
Yang, Jay
author_sort Kim, Hung Tae
collection PubMed
description The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber. NEW METHODS: We developed novel data acquisition hardware and software, data analysis software, and a conditioning protocol for an automated high throughput static weight-bearing assessment of pain. With this device, the rats voluntarily enter the weighing chamber, precluding the necessity to restrain the animals and thereby removing the potential stress-induced confounds as well as operator selection bias during data collection. We name this device the Voluntarily Accessed Static Incapacitance Chamber (VASIC). RESULTS: Control rats subjected to the VASIC device provided hundreds of weight-bearing data points in a single behavioral assay. Chronic constriction injury (CCI) surgery and paw pad injection of complete Freund's adjuvant (CFA) or carrageenan in rats generated hundreds of weight-bearing data during a 30 minute recording session. Rats subjected to CCI, CFA, or carrageenan demonstrated the expected bias in weight distribution favoring the un-operated leg, and the analgesic effect of i.p. morphine was demonstrated. In comparison with existing methods, brief water restriction encouraged the rats to enter the weighing chamber to access water, and an infrared detector confirmed the rat position with feet properly positioned on the footplates, triggering data collection. This allowed hands-off measurement of weight distribution data reducing operator selection bias. CONCLUSION: The VASIC device should enhance the hands-free parallel collection of unbiased weight-bearing data in a high throughput manner, allowing further testing of this behavioral measure as an effective assessment of pain in rodents.
format Online
Article
Text
id pubmed-4586949
institution National Center for Biotechnology Information
language English
publishDate 2015
record_format MEDLINE/PubMed
spelling pubmed-45869492016-11-01 Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test Kim, Hung Tae Uchimoto, Kazuhiro Duellman, Tyler Yang, Jay Physiol Behav Article The weight-bearing test is one method to assess pain in rodent animal models; however, the acceptance of this convenient method is limited by the low throughput data acquisition and necessity of confining the rodents to a small chamber. NEW METHODS: We developed novel data acquisition hardware and software, data analysis software, and a conditioning protocol for an automated high throughput static weight-bearing assessment of pain. With this device, the rats voluntarily enter the weighing chamber, precluding the necessity to restrain the animals and thereby removing the potential stress-induced confounds as well as operator selection bias during data collection. We name this device the Voluntarily Accessed Static Incapacitance Chamber (VASIC). RESULTS: Control rats subjected to the VASIC device provided hundreds of weight-bearing data points in a single behavioral assay. Chronic constriction injury (CCI) surgery and paw pad injection of complete Freund's adjuvant (CFA) or carrageenan in rats generated hundreds of weight-bearing data during a 30 minute recording session. Rats subjected to CCI, CFA, or carrageenan demonstrated the expected bias in weight distribution favoring the un-operated leg, and the analgesic effect of i.p. morphine was demonstrated. In comparison with existing methods, brief water restriction encouraged the rats to enter the weighing chamber to access water, and an infrared detector confirmed the rat position with feet properly positioned on the footplates, triggering data collection. This allowed hands-off measurement of weight distribution data reducing operator selection bias. CONCLUSION: The VASIC device should enhance the hands-free parallel collection of unbiased weight-bearing data in a high throughput manner, allowing further testing of this behavioral measure as an effective assessment of pain in rodents. 2015-07-21 2015-11-01 /pmc/articles/PMC4586949/ /pubmed/26143745 http://dx.doi.org/10.1016/j.physbeh.2015.06.035 Text en This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Kim, Hung Tae
Uchimoto, Kazuhiro
Duellman, Tyler
Yang, Jay
Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
title Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
title_full Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
title_fullStr Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
title_full_unstemmed Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
title_short Automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
title_sort automated assessment of pain in rats using a voluntarily accessed static weight-bearing test
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4586949/
https://www.ncbi.nlm.nih.gov/pubmed/26143745
http://dx.doi.org/10.1016/j.physbeh.2015.06.035
work_keys_str_mv AT kimhungtae automatedassessmentofpaininratsusingavoluntarilyaccessedstaticweightbearingtest
AT uchimotokazuhiro automatedassessmentofpaininratsusingavoluntarilyaccessedstaticweightbearingtest
AT duellmantyler automatedassessmentofpaininratsusingavoluntarilyaccessedstaticweightbearingtest
AT yangjay automatedassessmentofpaininratsusingavoluntarilyaccessedstaticweightbearingtest