Cargando…

A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day

The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the...

Descripción completa

Detalles Bibliográficos
Autores principales: Hosp, Fabian, Scheltema, Richard A., Eberl, H. Christian, Kulak, Nils A., Keilhauer, Eva C., Mayr, Korbinian, Mann, Matthias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The American Society for Biochemistry and Molecular Biology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4587330/
https://www.ncbi.nlm.nih.gov/pubmed/25887394
http://dx.doi.org/10.1074/mcp.O115.049460
_version_ 1782392474683047936
author Hosp, Fabian
Scheltema, Richard A.
Eberl, H. Christian
Kulak, Nils A.
Keilhauer, Eva C.
Mayr, Korbinian
Mann, Matthias
author_facet Hosp, Fabian
Scheltema, Richard A.
Eberl, H. Christian
Kulak, Nils A.
Keilhauer, Eva C.
Mayr, Korbinian
Mann, Matthias
author_sort Hosp, Fabian
collection PubMed
description The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the research context at hand or resulting from extensive fractionation. At the same time, investigation of many conditions or perturbations puts a strain on measurement capacity. Here, we develop a high-throughput workflow capable of dealing with large numbers of low or medium complexity samples and specifically aim at the analysis of 96-well plates in a single day (15 min per sample). We combine parallel sample processing with a modified liquid chromatography platform driving two analytical columns in tandem, which are coupled to a quadrupole Orbitrap mass spectrometer (Q Exactive HF). The modified LC platform eliminates idle time between measurements, and the high sequencing speed of the Q Exactive HF reduces required measurement time. We apply the pipeline to the yeast chromatin remodeling landscape and demonstrate quantification of 96 pull-downs of chromatin complexes in about 1 day. This is achieved with only 500 μg input material, enabling yeast cultivation in a 96-well format. Our system retrieved known complex-members and the high throughput allowed probing with many bait proteins. Even alternative complex compositions were detectable in these very short gradients. Thus, sample throughput, sensitivity and LC/MS-MS duty cycle are improved severalfold compared with established workflows. The pipeline can be extended to different types of interaction studies and to other medium complexity proteomes.
format Online
Article
Text
id pubmed-4587330
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The American Society for Biochemistry and Molecular Biology
record_format MEDLINE/PubMed
spelling pubmed-45873302015-09-29 A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day Hosp, Fabian Scheltema, Richard A. Eberl, H. Christian Kulak, Nils A. Keilhauer, Eva C. Mayr, Korbinian Mann, Matthias Mol Cell Proteomics Technological Innovations and Resources The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the research context at hand or resulting from extensive fractionation. At the same time, investigation of many conditions or perturbations puts a strain on measurement capacity. Here, we develop a high-throughput workflow capable of dealing with large numbers of low or medium complexity samples and specifically aim at the analysis of 96-well plates in a single day (15 min per sample). We combine parallel sample processing with a modified liquid chromatography platform driving two analytical columns in tandem, which are coupled to a quadrupole Orbitrap mass spectrometer (Q Exactive HF). The modified LC platform eliminates idle time between measurements, and the high sequencing speed of the Q Exactive HF reduces required measurement time. We apply the pipeline to the yeast chromatin remodeling landscape and demonstrate quantification of 96 pull-downs of chromatin complexes in about 1 day. This is achieved with only 500 μg input material, enabling yeast cultivation in a 96-well format. Our system retrieved known complex-members and the high throughput allowed probing with many bait proteins. Even alternative complex compositions were detectable in these very short gradients. Thus, sample throughput, sensitivity and LC/MS-MS duty cycle are improved severalfold compared with established workflows. The pipeline can be extended to different types of interaction studies and to other medium complexity proteomes. The American Society for Biochemistry and Molecular Biology 2015-07 2015-04-17 /pmc/articles/PMC4587330/ /pubmed/25887394 http://dx.doi.org/10.1074/mcp.O115.049460 Text en © 2015 by The American Society for Biochemistry and Molecular Biology, Inc. Author's Choice—Final version free via Creative Commons CC-BY license (http://creativecommons.org/licenses/by/3.0) .
spellingShingle Technological Innovations and Resources
Hosp, Fabian
Scheltema, Richard A.
Eberl, H. Christian
Kulak, Nils A.
Keilhauer, Eva C.
Mayr, Korbinian
Mann, Matthias
A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
title A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
title_full A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
title_fullStr A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
title_full_unstemmed A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
title_short A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
title_sort double-barrel liquid chromatography-tandem mass spectrometry (lc-ms/ms) system to quantify 96 interactomes per day
topic Technological Innovations and Resources
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4587330/
https://www.ncbi.nlm.nih.gov/pubmed/25887394
http://dx.doi.org/10.1074/mcp.O115.049460
work_keys_str_mv AT hospfabian adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT scheltemaricharda adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT eberlhchristian adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT kulaknilsa adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT keilhauerevac adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT mayrkorbinian adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT mannmatthias adoublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT hospfabian doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT scheltemaricharda doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT eberlhchristian doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT kulaknilsa doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT keilhauerevac doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT mayrkorbinian doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday
AT mannmatthias doublebarrelliquidchromatographytandemmassspectrometrylcmsmssystemtoquantify96interactomesperday