Cargando…
Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes
BACKGROUND: This randomized, partially single-blinded, 6-period crossover clinical study of adult smokers compared the nicotine pharmacokinetics, impacts on smoking urge and tolerability of various formulations of one brand of e-cigarettes with that of a tobacco cigarette. METHODS: Five e-cigarettes...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4588874/ https://www.ncbi.nlm.nih.gov/pubmed/26424091 http://dx.doi.org/10.1186/s12889-015-2349-2 |
_version_ | 1782392698749059072 |
---|---|
author | D’Ruiz, Carl D. Graff, Donald W. Yan, X. Sherwin |
author_facet | D’Ruiz, Carl D. Graff, Donald W. Yan, X. Sherwin |
author_sort | D’Ruiz, Carl D. |
collection | PubMed |
description | BACKGROUND: This randomized, partially single-blinded, 6-period crossover clinical study of adult smokers compared the nicotine pharmacokinetics, impacts on smoking urge and tolerability of various formulations of one brand of e-cigarettes with that of a tobacco cigarette. METHODS: Five e-cigarettes with different e-liquid formulations containing 1.6 % and 2.4 % nicotine and a conventional tobacco cigarette were randomized among 24 subjects under two exposure sessions consisting of a 30-min controlled and a one-hour ad lib use period to assess plasma nicotine levels, impacts on smoking urge and adverse events. The 30-min controlled use session comprised an intensive use of the e-cigarettes with a total of 50 puffs taken every 30 s for comparison to a single conventional cigarette having a typical machine-measured nicotine yield (~0.8 mg). Ad lib product use conditions provided insight into more naturalistic product use behaviors and their accompanying smoking urge reductions. Adverse events (AEs) were assessed by the Principal Investigator. RESULTS: Significant (p < 0.05) increases in plasma nicotine concentrations occurred within 10 min of controlled e-cigarette use and significant (p < 0.001) reductions from baseline smoking urge were observed within 5 min. E-cigarette and cigarette nicotine plasma levels were comparable for up to one hour of use. After both sessions (90 min), nicotine exposure was the highest for the cigarette, with all e-cigarettes showing 23 % to 53 % lower plasma concentrations. During controlled use, peak reduction in smoking urge for e-cigs occurred later than for the cigarette. After completion of both sessions, significant smoking urge reduction persisted for most of the tested e-cigarettes, albeit at levels lower than that provided by the tobacco cigarette. Nicotine content, vehicle differences, and the presence of menthol did not significantly affect smoking urge reduction by the e-cigarettes. No subjects were discontinued due to AEs. The most frequently reported AEs events included cough, throat irritation, headache, and dizziness. CONCLUSIONS: Blood plasma nicotine levels obtained from short-term use of e-cigarettes containing 1.6 % and 2.4 % nicotine were significant, but lower than those of conventional tobacco cigarettes, yet the reduction in craving symptoms were broadly comparable. The types of AEs were consistent with other research studies of longer duration that have reported that use of e-cigarettes by adult smokers is well-tolerated. TRIAL REGISTRATION: http://ClinicalTrials.gov identifier: NCT02210754. Registered 8 August 2014. |
format | Online Article Text |
id | pubmed-4588874 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-45888742015-10-01 Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes D’Ruiz, Carl D. Graff, Donald W. Yan, X. Sherwin BMC Public Health Research Article BACKGROUND: This randomized, partially single-blinded, 6-period crossover clinical study of adult smokers compared the nicotine pharmacokinetics, impacts on smoking urge and tolerability of various formulations of one brand of e-cigarettes with that of a tobacco cigarette. METHODS: Five e-cigarettes with different e-liquid formulations containing 1.6 % and 2.4 % nicotine and a conventional tobacco cigarette were randomized among 24 subjects under two exposure sessions consisting of a 30-min controlled and a one-hour ad lib use period to assess plasma nicotine levels, impacts on smoking urge and adverse events. The 30-min controlled use session comprised an intensive use of the e-cigarettes with a total of 50 puffs taken every 30 s for comparison to a single conventional cigarette having a typical machine-measured nicotine yield (~0.8 mg). Ad lib product use conditions provided insight into more naturalistic product use behaviors and their accompanying smoking urge reductions. Adverse events (AEs) were assessed by the Principal Investigator. RESULTS: Significant (p < 0.05) increases in plasma nicotine concentrations occurred within 10 min of controlled e-cigarette use and significant (p < 0.001) reductions from baseline smoking urge were observed within 5 min. E-cigarette and cigarette nicotine plasma levels were comparable for up to one hour of use. After both sessions (90 min), nicotine exposure was the highest for the cigarette, with all e-cigarettes showing 23 % to 53 % lower plasma concentrations. During controlled use, peak reduction in smoking urge for e-cigs occurred later than for the cigarette. After completion of both sessions, significant smoking urge reduction persisted for most of the tested e-cigarettes, albeit at levels lower than that provided by the tobacco cigarette. Nicotine content, vehicle differences, and the presence of menthol did not significantly affect smoking urge reduction by the e-cigarettes. No subjects were discontinued due to AEs. The most frequently reported AEs events included cough, throat irritation, headache, and dizziness. CONCLUSIONS: Blood plasma nicotine levels obtained from short-term use of e-cigarettes containing 1.6 % and 2.4 % nicotine were significant, but lower than those of conventional tobacco cigarettes, yet the reduction in craving symptoms were broadly comparable. The types of AEs were consistent with other research studies of longer duration that have reported that use of e-cigarettes by adult smokers is well-tolerated. TRIAL REGISTRATION: http://ClinicalTrials.gov identifier: NCT02210754. Registered 8 August 2014. BioMed Central 2015-09-30 /pmc/articles/PMC4588874/ /pubmed/26424091 http://dx.doi.org/10.1186/s12889-015-2349-2 Text en © D’Ruiz et al. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article D’Ruiz, Carl D. Graff, Donald W. Yan, X. Sherwin Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
title | Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
title_full | Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
title_fullStr | Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
title_full_unstemmed | Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
title_short | Nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
title_sort | nicotine delivery, tolerability and reduction of smoking urge in smokers following short-term use of one brand of electronic cigarettes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4588874/ https://www.ncbi.nlm.nih.gov/pubmed/26424091 http://dx.doi.org/10.1186/s12889-015-2349-2 |
work_keys_str_mv | AT druizcarld nicotinedeliverytolerabilityandreductionofsmokingurgeinsmokersfollowingshorttermuseofonebrandofelectroniccigarettes AT graffdonaldw nicotinedeliverytolerabilityandreductionofsmokingurgeinsmokersfollowingshorttermuseofonebrandofelectroniccigarettes AT yanxsherwin nicotinedeliverytolerabilityandreductionofsmokingurgeinsmokersfollowingshorttermuseofonebrandofelectroniccigarettes |